Brand: Meinberg
Meinberg LANTIME M2000S Modular 2U Time Server
Description
Overview
The Meinberg LANTIME M2000S compresses Meinberg’s modular synchronization concept into a two-unit rack chassis with all connections on one side. It acts as an NTP time server, can be equipped as a PTP grandmaster or slave, and provides pulses, frequencies and time codes through plug-in modules. Seven Star LLC is an independent supplier serving Oman and the GCC. The text below paraphrases Meinberg’s datasheet and focuses on the points that matter when specifying the chassis.
Single-sided access and compact depth
Because every connector and control element is on one face, the M2000S can be mounted on a wall or in a rack that has access from only one side. The reduced depth permits 300 mm ETSI racks, and 21 inch racks are possible with an adapter. This is a practical advantage in telecom cabinets, substation control rooms and small equipment rooms, where space behind the rack is often not available. No front display is fitted, so the unit is configured through its web user interface, called WebUI, or the console utility.
Slots and modules of the Meinberg LANTIME M2000S
| Item | Value |
|---|---|
| Chassis | 2U rackmount for 19 inch racks; 21 inch with adapter; 300 mm ETSI depth |
| Slots | 3 power supply, 2 clock, 1 CPU, 6 free configurable input/output |
| Slot types | IMS-CLK, IMS-PWR, IMS-CPU, IMS-ESI, IMS-MRI, IMS-IO |
| Reference sources | GPS, GLONASS, Galileo, BeiDou, PZF, PTP/IEEE 1588, NTP, SyncE, IRIG/AFNOR, PPS, 10 MHz, 2.048 kHz, E1/T1 |
| Pulse output accuracy | better than plus or minus 50 ns with OCXO SQ, HQ or DHQ |
| PTP | up to 6 PTP (IEEE 1588-2008) modules; grandmaster or slave optional |
| NTP performance | up to 25,000 requests per second, depending on CPU module |
| Additional LAN ports | up to 24 gigabit ports |
| Protocols | NTP, SNTP, PRP IEC 62439-3, HTTP(S), SSH, Telnet, SNMP v1 to v3, FTP, SFTP, DHCP, DHCPv6 |
| Power supplies | AD10 90 to 265 V AC / 90 to 250 V DC; DC20 20 to 60 V DC; DC10 10 to 36 V DC |
| Interfaces | up to 99 logical network interfaces with IPv4 and IPv6, VLAN capable |
Design choices for the Meinberg LANTIME M2000S
The six free slots can hold, for example, modules that together create 24 pulse or 10 MHz outputs, which suits laboratories and broadcast facilities that must feed many instruments from a common reference. The input slot types allow 2048 kHz, 2.048 Mbit per second and variable frequency inputs, and IRIG, 1PPS and 10 MHz inputs. Adding a second clock module gives redundancy for the receiver, and the three power supply slots allow redundant AC and DC feeds to be combined. Meinberg also offers DHQ oscillators for the best holdover.
How LANTIME M2000S differs from the M3000S and M1000
Next to the 3U M3000S, with four power supply slots, ten input and output slots and up to ten PTP modules, the M2000S is smaller: three power supplies, six input and output slots and up to six PTP modules. It does not have the seamless switchover card slot that the M3000S offers for the RSC module. Compared with the 1U M1000, which is on the market as a more compact system, the M2000S offers more slots and redundancy. Pick it when the application needs the single-sided mounting and a moderate number of outputs.
Choosing modules for the M2000S
Start from the list of devices that need time. Network clients such as servers, switches and workstations use NTP and need no module at all beyond the CPU. Protection relays and recorders typically need IRIG-B or PPS and take an output module. Telecom equipment may need 2048 kHz or E1 outputs and the matching input modules, and measurement laboratories need 10 MHz and PPS. Count the outputs per type, add spare capacity of about twenty percent for growth, and check that the six slots are enough; if they are not, the M3000S with ten slots may be the better chassis. Also decide which references the system will use and how they are prioritised, since priority, bias and precision can be configured for every source.
Typical uses in the region
Substations that implement IEC 61850 need accurate time at the process and station bus, telecom operators need frequency references and time of day, and data centres need traceable NTP. All of these exist in Oman and across the Gulf. A single M2000S can distribute NTP to hundreds of clients, supply IRIG-B to relays and recorders and give PPS to test equipment, and the web interface makes remote administration straightforward. Choose the reference to suit the site: a GNSS module with a rooftop antenna is common, supplemented by PTP or IRIG input where roof access is limited.
Accuracy and holdover in practice
Pulse outputs are specified as better than plus or minus 50 nanoseconds relative to the reference when an OCXO oscillator is installed, and the quality of the oscillator decides how well the system rides through the loss of its reference. If the antenna cable is damaged or GNSS is jammed, the oscillator keeps the outputs in step until the reference returns, and a better oscillator holds the specification longer. Choose the oscillator by asking how many hours of autonomous operation the application can accept, and what error the connected equipment tolerates during that time. For protection relays and phasor measurement units that need microsecond accuracy, a modest oscillator is enough, while telecom and broadcast systems may require the best grade.
Security and monitoring
The system supports symmetric key authentication with MD5, SHA-1 or AES-128-CMAC, NTP version 4 Autokey and Network Time Security. SNMP traps and syslog allow integration into network monitoring, and status of each reference and output is visible on the web interface. Because modules hot plug, maintenance can be carried out without stopping unaffected services. Keep firmware current to receive security fixes and new functions.
Related items you may also need: Meinberg LANTIME M250 Compact NTP Time Server | Meinberg LANTIME M500 Modular DIN-Rail Time Server | Meinberg LANTIME M320/GPS/AD10 NTP Time Server | All Meinberg products.
Points to confirm for the Meinberg LANTIME M2000S
- If the Meinberg LANTIME M2000S is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Meinberg LANTIME M2000S request we confirm the exact code and lead time in writing.
- Dimensions, ratings and connection data for the Meinberg LANTIME M2000S are in the datasheet attached to this page.
- The Meinberg LANTIME M2000S belongs to our industrial communications range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Meinberg LANTIME M2000S on critical service often hold a spare unit in the store.
Documents and quotation
Meinberg’s datasheet for the Meinberg LANTIME M2000S is attached. Since the platform is built from modules, please send your RFQ with the model, receiver type, oscillator, power supplies, output modules and quantities, and your delivery location in Oman or the GCC.
Other Models in the IMS Range
Seven Star LLC supplies models from the IMS range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Meinberg LANTIME M3000S Modular 3U Synchronization System | Industrial Communications | View details |
| Meinberg LANTIME M2000S Modular 2U Time Server | Industrial Communications | You are viewing this model |
Datasheets & Documents
- Datasheet Meinberg LANTIME M2000S Modular 2U Time Server Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Meinberg is a German maker of time and frequency synchronisation products, founded in 1979 by the brothers Werner and Günter Meinberg in Bad Pyrmont. It began with DCF77 longwave radio clock receivers and now makes GPS and GNSS-referenced NTP and PTP time servers. Meinberg is family-owned and designs and manufactures its products in Bad Pyrmont.
Seven Star LLC sources and supplies Meinberg LANTIME time servers for utilities and networks in Oman, including the M1000 and M320 listed here.
Meinberg company profile
| Founded | 1979, Bad Pyrmont, Germany |
|---|---|
| Founders | Werner and Günter Meinberg |
| Ownership | Family-owned |
| Manufacturing | Bad Pyrmont, Germany |
| Product families | LANTIME M150, M250, M320, M500 and M1000 NTP/PTP time servers, IMS modular systems, GNSS and DCF77 receivers, PTP grandmaster clocks |
Meinberg LANTIME models listed here
The LANTIME M320 is a 1U rackmount NTP time server. It works as a stratum 1 source with its own reference receiver, and Meinberg offers it with GPS, combined GNSS, DCF77 (PZF), MSF and IRIG time code references. The LANTIME M1000 is a 1U platform on the modular IMS system, with slots for up to two reference clocks, two power supplies and hot-pluggable I/O modules, plus PTP (IEEE 1588) and IEC 61850 time synchronization.
Meinberg products we list
Ordering a Meinberg time server: what we need
A Meinberg order code describes the build. In M320/GPS/AD10, GPS is the receiver and AD10 is the wide-range AC/DC power supply. Send the full code or serial number, the reference source, oscillator option, supply voltage, the outputs you need (PPS, 10 MHz, IRIG, extra LAN ports) and the antenna cable length. GCC utility projects often require redundant supplies.
Facts checked against Meinberg's own company history (meinbergglobal.com), October 2026.
Browse Meinberg products by category: Industrial Communications.
FAQ
Questions about the Meinberg LANTIME M2000S Modular 2U Time Server
Answers from our engineering team on installation, compatibility and integration.
01How many input and output slots does the Meinberg LANTIME M2000S have?
It offers six free configurable input and output slots, three power supply slots, two clock slots and one CPU slot in a 2U chassis.
02Why choose the S housing of the M2000S?
All connections and controls are on one side, so it can be wall mounted or installed in racks accessible from one side, and it fits 300 mm ETSI racks.
03Can the M2000S act as a PTP grandmaster?
Yes, IEEE 1588 PTP grandmaster or slave operation is optional, with up to six PTP modules.
04What power supplies are available for the LANTIME M2000S?
AD10 for 90 to 265 V AC or 90 to 250 V DC, DC20 for 20 to 60 V DC and DC10 for 10 to 36 V DC, with up to three installed redundantly.
05How is the M2000S configured without a front display?
Through the web user interface WebUI or the console-based configuration utility over the network.