Lincoln Electric SuperArc L-59 ER70S-6 Solid MIG Welding Wire

Description

Overview

Lincoln Electric SuperArc L-59 is a copper coated mild steel solid wire classified as AWS ER70S-6 and intended for gas metal arc welding, commonly called MIG or GMAW. It belongs to the SuperArc family of solid wires from Lincoln Electric and is one of the most widely specified general purpose carbon steel wires in structural, pressure and automated fabrication. The manufacturer datasheet lists an engineered alloy system that improves silicon island management, minimal spatter, a copper coating for long contact tip life, fast travel speeds and a MicroGuard Ultra surface treatment for superior feeding and arc stability.

Seven Star LLC supplies Lincoln Electric SuperArc L-59 to fabricators, EPC contractors and maintenance workshops in the Sultanate of Oman and the wider GCC, with engineering support from Muscat. Buyers who need a deoxidised ER70S-6 wire that tolerates mill scale, handles both short circuit and spray transfer, and runs on robotic cells as well as semi-automatic guns can request this product together with the datasheet and the matching shielding gas recommendation.

How a Solid ER70S-6 Wire Works in the Arc

In the GMAW process a continuously fed solid wire carries welding current, melts in the arc and transfers into the joint while a flow of shielding gas displaces air from the molten pool. The ER70S-6 designation means a solid electrode (the letter S) with a minimum tensile strength of 70 ksi (the digits 70) and a chemistry tagged 6, which carries the highest silicon and manganese levels of the common mild steel wires. Those deoxidisers combine with oxygen in the weld pool, forming small silicate islands on the bead surface while leaving a sound, pore free deposit. This is why Lincoln Electric SuperArc L-59 tolerates light rust and mill scale better than low silicon wires such as ER70S-3.

The same deoxidiser content in Lincoln Electric SuperArc L-59 allows wider choices of shielding gas. According to the datasheet, Lincoln Electric SuperArc L-59 is used with 100 percent CO2, with argon and CO2 mixtures in the range 75 to 95 percent argon, and with 95 to 98 percent argon and balance oxygen, at a flow rate of 30 to 50 CFH. With Lincoln Electric SuperArc L-59, pure CO2 gives deeper penetration and lower gas cost, argon rich mixtures give a smoother spray arc with less spatter, and the choice moves the typical mechanical results shown in the table below.

Engineering Design of the Lincoln Electric SuperArc L-59 Wire

Lincoln Electric SuperArc L-59 is drawn from a controlled alloy rod and given a thin copper coating. The coating protects the surface during storage, lowers friction in the liner and conduit, and improves electrical contact in the tip, which the manufacturer links directly to long contact tip life. MicroGuard Ultra is the surface finish named in the datasheet for consistent feeding and arc stability, which matters most on long conduit runs and robotic torches where a small increase in friction becomes a feeding fault.

Lincoln Electric lists diameters of 0.035, 0.040, 0.045, 0.052 and 1/16 inch (0.9, 1.0, 1.1, 1.3 and 1.6 mm). The reference packages in the datasheet include 33 lb plastic spools, 44 lb fiber or steel spools, 60 lb fiber spools, 500 lb and 900 lb Accu-Pak boxes, Infinity-Pak containers, a 1000 lb Accu-Pak box and a 1000 lb Precise-Trak reel for high volume cells. These are the manufacturer reference packages, not a statement of Seven Star stock; please ask for current availability.

Key Features of Lincoln Electric SuperArc L-59

The following points are taken from the manufacturer datasheet and describe what Lincoln Electric SuperArc L-59 offers a welding shop:

  • An engineered alloy system that enhances silicon island management on the finished bead, reducing the cleaning needed before painting or a following pass.
  • Minimal spatter, which cuts grinding time and nozzle cleaning in production welding.
  • A copper coating that supports long contact tip life and consistent current transfer.
  • Fast travel speeds that suit thin to medium plate and high duty cycle automation.
  • MicroGuard Ultra treatment that gives superior feeding and arc stability through long conduit.
  • Suitability for all welding positions, with 100 percent CO2, argon and CO2 blends or argon and oxygen blends.
  • Conformance to AWS A5.18 ER70S-6 and ASME SFA-A5.18, together with the classifications listed in the specification table.
  • A wide range of reference packaging from 33 lb spools to 1000 lb bulk packs for different production volumes.

Industrial Applications in Oman and the GCC

For Lincoln Electric SuperArc L-59 the datasheet lists robotic or hard automation, automotive, pipeline and offshore work, pressure vessels, heavy fabrication and use as an alternative to metal cored wire. In Oman these map onto structural steel shops in Sohar and Rusayl, skid and piping fabrication yards supporting oil and gas projects, pressure vessel and tank workshops, and general engineering shops in Muscat and Salalah. The high deoxidiser content makes Lincoln Electric SuperArc L-59 a practical choice where plate arrives with light surface scale and where welders switch between short circuit transfer on thin sections and spray transfer on thicker joints.

Seven Star LLC supplies Lincoln Electric SuperArc L-59 alongside other consumables and welding power sources, so a project team can align wire diameter, gas and machine settings in one enquiry. A multi-process inverter such as the Lincoln Electric Power Wave S500 can run solid wire in pulsed and synergic modes, while a compact unit such as the ESAB Rebel EMP 285ic suits site and maintenance work. For a mixed equipment order the Kobelco Lubricator Assembly page shows how Seven Star also supports industrial machinery spares.

Typical Settings Printed by the Manufacturer

The datasheet publishes operating procedures for each diameter with direct current electrode positive polarity. For 0.035 inch (0.9 mm) wire the listed settings run from 2.5 m/min wire feed speed at 17 V and about 80 A up to 15.2 m/min at 30 V and about 275 A, with a contact tip to work distance of 12 mm for short circuit procedures and 19 mm for spray procedures. Larger Lincoln Electric SuperArc L-59 diameters carry higher current for the same feed speed, and the sheet notes that for 100 percent CO2 short circuit procedures 1 to 2 volts should be added to the 75 percent argon values. Use these Lincoln Electric SuperArc L-59 figures as a starting point only and qualify the final procedure on your own material.

Technical Specifications of Lincoln Electric SuperArc L-59

The table below reproduces the key values printed in the Lincoln Electric SuperArc L-59 datasheet. Typical results are all weld metal values reported by the manufacturer and are not a guarantee for a particular application.

Parameter Specification
Model Lincoln Electric SuperArc L-59
Wire type Mild steel solid MIG wire, copper coated
AWS classification AWS A5.18/A5.18M ER70S-6; ASME SFA-A5.18 ER70S-6
Other conformances listed ABS 3YSA (100 percent CO2 and mixed gas); DNV III YMS H5 (mixed gas); BV SA3YHHH (mixed gas); CWB/CSA W48-06 ER49S-6; EN ISO 14341-B G 49A 3 C S6
Welding positions All
Shielding gas 100 percent CO2; 75-95 percent Ar / balance CO2; 95-98 percent Ar / balance O2; flow 30-50 CFH
Diameters 0.035, 0.040, 0.045, 0.052, 1/16 in (0.9, 1.0, 1.1, 1.3, 1.6 mm)
AWS requirement, 100 percent CO2 Yield 400 MPa (58 ksi) min; tensile 485 MPa (70 ksi) min; elongation 22 percent min; 27 J (20 ft-lbf) min at -29 C
Typical, 100 percent CO2 Yield 455 MPa (66 ksi); tensile 565 MPa (82 ksi); elongation 28 percent; 71 J (52 ft-lbf) at -29 C; 53 J (39 ft-lbf) at -40 C
Typical, 75 percent Ar / 25 percent CO2 Yield 485 MPa (70 ksi); tensile 595 MPa (86 ksi); elongation 25 percent; 56 J (41 ft-lbf) at -29 C; 53 J (39 ft-lbf) at -40 C
Typical, 90 percent Ar / 10 percent CO2 Yield 460 MPa (67 ksi); tensile 570 MPa (83 ksi); elongation 25 percent; 75 J (55 ft-lbf) at -29 C; 65 J (48 ft-lbf) at -40 C
Wire composition (AWS requirement) C 0.06-0.15; Mn 1.40-1.85; Si 0.80-1.15; S 0.035 max; P 0.025 max; Cu 0.50 max; Ni 0.15 max; Cr 0.15 max; Mo 0.15 max; V 0.03 max (percent)
Polarity DC electrode positive

Handling and Storage Notes

Lincoln Electric SuperArc L-59 as a solid wire is far less moisture sensitive than a flux cored wire, but good practice still applies. Keep spools in their sealed packaging until needed, store them in a dry area away from direct contact with floors and wall condensation, and cover a spool on the feeder during long shutdowns to keep out dust and humidity. This is general welding practice, not a Lincoln Electric statement. In the coastal climate of Muscat and Sohar, wrapped spools returned to the store after a shift stay cleaner and feed more reliably.

Call To Action

To order Lincoln Electric SuperArc L-59, send Seven Star LLC your diameter, package size, quantity and shielding gas, and our team in Muscat will prepare a formal quotation and confirm availability for delivery across Oman and the GCC. The manufacturer datasheet is attached to this page for download, and our engineers can help match the wire to your power source and procedure. Seven Star LLC supplies Lincoln Electric products as a trusted supplier with engineering support in Muscat, so contact the instrumentation and industrial supply division with your request today.

Datasheets & Documents
  • PDF Datasheet Lincoln Electric SuperArc L-59 datasheet (manufacturer publication) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Lincoln Electric is a world leader in the design, development, and manufacture of arc welding products, robotic welding systems, and cutting equipment, serving heavy fabrication, shipbuilding, construction, pipeline, and general manufacturing industries worldwide. Its Power Wave series of inverter-based multi-process welders is widely regarded as an industry benchmark for advanced waveform control, offering precise arc characteristics across MIG, pulsed MIG, flux-cored, stick, and TIG welding processes for demanding industrial fabrication work. The company also produces consumables, wire feeders, automation cells, and welding safety equipment, backed by an extensive global distributor and service network. As a trusted supplier of Lincoln Electric in Oman and the GCC, Seven Star LLC supplies genuine Lincoln Electric welding equipment and consumables to fabrication shops, EPC contractors, and industrial maintenance teams across the region, ensuring reliable weld quality, warranty support, and access to certified spare parts.

Frequently Asked Questions

What shielding gas does Lincoln Electric SuperArc L-59 use?
The manufacturer datasheet lists 100 percent CO2, 75 to 95 percent argon with balance CO2, and 95 to 98 percent argon with balance oxygen, at a flow rate of 30 to 50 CFH. The gas choice changes penetration, spatter level and the typical mechanical results.
Which AWS class is Lincoln Electric SuperArc L-59?
It is classified AWS A5.18/A5.18M ER70S-6 and ASME SFA-A5.18 ER70S-6. The datasheet also lists EN ISO 14341-B G 49A 3 C S6 and CWB/CSA W48-06 ER49S-6, plus ABS, DNV and BV grades for specific gas conditions.
Which wire diameters are listed for Lincoln Electric SuperArc L-59?
The datasheet lists 0.035, 0.040, 0.045, 0.052 and 1/16 inch, equal to 0.9, 1.0, 1.1, 1.3 and 1.6 mm, in reference packages from 33 lb spools up to 1000 lb bulk packs. Ask Seven Star LLC which sizes and packs can be supplied for your order.
Can this wire weld in all positions?
Yes. The manufacturer lists all welding positions for SuperArc L-59, and short circuit transfer is the usual choice for thin sections and out of position work, while spray transfer suits flat and horizontal welds on thicker plate.
Does Seven Star LLC supply Lincoln Electric SuperArc L-59 in Oman and the GCC?
Yes. Seven Star LLC supplies Lincoln Electric products as a trusted supplier to customers in Oman and the GCC, with engineering support in Muscat. Send us your quantity and delivery location for a formal quotation, and check the manufacturer datasheet for the governing specification.