Brand: KRACHT
KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350 bar
Description
High-pressure cast iron gear meter VCG 2 M1F1P2SH
KRACHT VCG 2 M1F1P2SH is the cast iron relative of the VCA size 2. The housing and cover are spheroidal cast iron GJS-400, the gears are steel, and a multi-layer plain bearing carries the load, which lets the meter work at 350 bar and at media temperatures up to 120 C.
The code reads VCG 2 (size), M (multi-layer plain bearing), 1 (cast iron housing with steel gears), F (FKM seals), 1 (standard coating), P (plate mounting), 2 (two sensors), S (standard pre-amplifier) and H (Hirschmann socket).
Specifications of VCG 2 M1F1P2SH
| Parameter | Value |
|---|---|
| Type code | VCG 2 M1F1P2SH |
| Geometric tooth volume | 2.000 cm3 |
| Measuring range | 1.00 to 65 l/min |
| Measuring unit starting at | 0.04 l/min at 100 mm2/s |
| Resolution per channel | 500.00 pulses per litre |
| Maximum pressure | 350 bar |
| Weight | 5.0 kg |
| Typical accuracy | plus/minus 2.5 percent from 20 mm2/s |
| Maximum pressure loss | 16 bar |
| Media temperature | -15 to 120 C |
| Ambient temperature | -10 to 80 C |
| Viscosity | up to 4,000 mm2/s |
| Sound pressure level | up to 60 dB(A) |
| Channels | 2, offset 90 degrees plus/minus 30 |
| Supply | 12 to 30 V DC |
| Protection | IP 65 |
Notes on the table: the 350 bar figure is the maximum pressure of the meter body, while the permissible pressure loss across the measuring unit is a separate limit of 16 bar. The sound pressure level of up to 60 dB(A) is the same as for the aluminium sizes, so the heavier cast iron body does not make the meter noisier. Ambient and media limits differ, and both must be respected.
Why choose VCG 2 M1F1P2SH instead of VCA 2
The tooth volume, range and resolution match the VCA 2, so the hydraulic capacity is the same. What changes is the housing and the rating: 350 bar instead of 200 bar, media up to 120 C instead of 80 C, weight 5.0 kg instead of 1.9 kg and two sensors instead of one. The trade-off is a typical accuracy of plus/minus 2.5 percent against plus/minus 1.0 percent for the aluminium meter.
Against the VCA 5 it offers more than three times the pressure rating at one third of the maximum flow.
The 2.5 percent typical accuracy is a considered trade-off. The datasheet quotes a wider tolerance for this cast iron model than for the aluminium sizes. For monitoring and trend duties it is entirely adequate; for custody-style accuracy a different principle or a calibrated aluminium meter at lower pressure would be a better choice.
Applications of VCG 2 M1F1P2SH in Oman and the Gulf
High-pressure hydraulics, injection of lube oil at pressure, hot oil circuits and test stands for pumps and valves are the sweet spot. The two channels give direction, so the meter can monitor cylinders that move oil both ways, for example in press and mobile-equipment test rigs.
A cast iron body tolerates workshop abuse better than aluminium and is chosen where the pressure peaks of a hydraulic system exceed 200 bar.
In Omani industry, high-pressure hydraulic systems on drilling-related equipment, cranes, presses and injection moulding machines run at pressures where an aluminium housing is not permitted. A meter that is rated for 350 bar can sit in the main pressure line and show the hydraulic consumption of the machine, which maintenance staff use for condition monitoring.
Because the media limit is 120 C, it can also measure hot lube oil and thermal oil at the lower end of that range, and the datasheet’s low media limit of -15 C covers cold starts of outdoor hydraulic equipment during the milder months. Add heat shielding between the meter and a hot pipe so that the electronics stay inside their ambient limit.
Selection and compatibility
Check the medium is lubricating, viscosity up to 4,000 mm2/s, and that the pressure loss stays below 16 bar. The ambient limit remains 80 C even though the medium may reach 120 C, so shield the electronics from radiant heat. Explosion-proof versions exist for the series.
Use plate mounting only; the VCG 2 is offered with plate mounting alone in the type key.
The standard coating (code 1) is a standard coating on the cast iron, while code 3 leaves the surface uncoated; choose coating 1 for outdoor or humid sites. The bearing is a multi-layer plain bearing, which depends on the lubricating film of the oil, so use it only with oils and not with dry or solvent-like fluids.
Installing VCG 2 M1F1P2SH
Wire the dual-channel plug: pin 1 supply (brown), pin 2 channel 1 (green), pin 3 channel 2 (yellow), pin 4 0 V (white). With 4-fold evaluation each edge of both channels is counted, which gives four times the resolution of the standard setting.
Mount the 5.0 kg body on a rigid plate and verify there are no leaks under pressure.
Cast iron at 5.0 kg needs a rigid mounting surface. Tighten fasteners as required and check the connection for leaks when the system is first pressurised to working pressure in steps. Keep signal cables away from power cables and use shielded cable if the run is long.
Before the first start, flush the line without the meter or with a bypass, because weld scale and cutting debris from new high-pressure piping are the most common cause of damaged gears on a freshly commissioned system.
Maintenance of VCG 2 M1F1P2SH
Keep filtration clean and verify the totaliser against a reference. Check seals for wear at hot operation, since the FKM seals age faster at the upper temperature limit.
Hot service ages seals, so inspect the FKM seals when the meter is removed. A drop in pulse count against a reference at constant flow is the typical sign of internal leakage past worn gears.
Ordering and related products
Ask for VCG 2 M1F1P2SH with quantity and confirm that you want the standard coating. Related models include VCA 2 M4F4P1SH, VCA 5 K5F4R1SH and VCA 0.2 U5F4R2SH.
Documents and quotation
The datasheet is attached. For availability send an RFQ naming VCG 2 M1F1P2SH and the quantity to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Other Models in the Kracht Vca Gear Range
Seven Star LLC supplies models from the Kracht Vca Gear range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10 l/min | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.2 U5F4R2SH Dual-Channel Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 2 M4F4P1SH Plate-Mounted Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 5 K5F4R1SH Gear Flow Meter up to 200 l/min | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350 bar | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350 bar Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350
Answers from our engineering team on installation, compatibility and integration.
01What is the pressure rating of KRACHT VCG 2 M1F1P2SH?
350 bar, the highest in the VCA/VCG size table.
02Up to what temperature can VCG 2 M1F1P2SH measure?
The media temperature is -15 to 120 C and ambient temperature is -10 to 80 C.
03Does VCG 2 M1F1P2SH detect direction?
Yes, the 2 in the code means two sensors offset by 90 degrees, which gives dual-channel output.
04How accurate is VCG 2 M1F1P2SH?
Typical accuracy is plus/minus 2.5 percent from a viscosity of 20 mm2/s.
05What material is VCG 2 M1F1P2SH?
Spheroidal cast iron housing and cover, steel gears, a multi-layer plain bearing and FKM seals.