KRACHT VC 1 K1F1P2SH Gear Flow Meter
Description
KRACHT VC 1 K1F1P2SH overview
KRACHT VC 1 K1F1P2SH is a KRACHT VC gear type flow meter of nominal size 1: two meshing gears turn as oil passes through, each tooth chamber holds 1.036 cm3, and magnetic sensors count the passing teeth to produce a pulse train that is proportional to volume.
In this configuration the measuring range is 0.4 to 80 l/min with a starting point of 0.02 l/min, so the unit can resolve very small flows without a straight inlet section.
Because K1 combines ball bearings with a cast iron housing, it is the common choice for lubricating media for instance oil, brake liquid, diesel and gear oil at low to medium viscosity.
The code K1F1P2SH decodes as ball-bearing K1 specification, FKM seal, coated surface, plate mounting, two sensors for direction detection, standard electronics and a Hirschmann socket.
Key features of VC 1 K1F1P2SH
- Pressure rating 480 bar and viscosity capability to 2 500 000 mm2/s
- Measuring range 0.4 to 80 l/min and starting point 0.02 l/min
- Sound level up to 70 dB(A) and weight 5.2 kg (spheroidal cast iron, integrated electronics)
- Pulsation-free measurement, any mounting position and any flow direction
- Tooth volume 1.036 cm3 returns 965.25 pulse/l per channel before the optional four-fold evaluation
- Bearing and material specification K1: ball bearing (code K), ball-bearing specification K1
VC 1 K1F1P2SH technical specifications
| Parameter | VC 1 K1F1P2SH |
|---|---|
| Type code | VC 1 K1F1P2SH |
| Permissible particle size | 20 micrometres |
| Highest pressure | 480 bar |
| Geometric tooth volume | 1.036 cm3 |
| Viscosity | up to 2 500 000 mm2/s |
| Accuracy | up to plus/minus 0.3 percent of reading (DAkkS-traceable); repeatability plus/minus 0.05 percent |
| Weight | 5.2 kg (spheroidal cast iron, integrated electronics) |
| Sensors / electronics | 2 sensors with standard pre-amplifier S and Hirschmann appliance socket H; supply 10 to 30 V, square-wave PNP/NPN/push-pull output, IP 65, highest 0.9 W |
| Bearings | ball bearing (code K), ball-bearing specification K1 |
| Measuring range | 0.4 to 80 l/min |
| Housing / gears | housing spheroidal cast iron GJS-400-15, gears steel 1.7131 |
| Sound pressure level | up to 70 dB(A) |
| Manufacturer | KRACHT GmbH, Werdohl, Germany |
| Series | VC gear type flow meter, nominal size 1 |
Reading the type key of VC 1 K1F1P2SH
| Position | Code and meaning |
|---|---|
| VC | gear type flow meter |
| 1 | nominal size 1 (tooth volume 1.036 cm3) |
| K | ball bearing |
| 1 | housing spheroidal cast iron GJS-400, steel gears |
| F | FKM sealing |
| 1 | coated surface |
| P | plate mounting |
| 2 | 2 sensors |
| S | standard pre-amplifier |
| H | Hirschmann appliance socket |
Position 3 and 4 together form the K1 specification; the data sheet specifies K1 for sizes 0.025 to 5 with ball bearing, spheroidal cast iron GJS-400 housing and steel gears.
The final two letters, S and H, name the electronics and the electrical connection; with a two-sensor version the flow direction can be detected from the phase shift of 90 degrees plus or minus 30 degrees.
How VC 1 K1F1P2SH differs from further VC variants
VC nominal sizes run 0.025, 0.04, 0.1, 0.2, 0.4, 1, 3, 5, 12, 16. VC 1 K1F1P2SH is size 1 with 1.036 cm3 tooth volume and a resolution of 965.25 pulse/l.
Compared with the next smaller size 0.4 (0.400 cm3, 2 500.00 pulse/l) this device has 0.636 cm3 more per tooth chamber, and its starting point increases from 0.01 to 0.02 l/min.
Relative to the next larger size 3 (3.000 cm3, 333.33 pulse/l) it offers finer resolution: 965.25 compared with 333.33 pulse/l, and starts to count at 0.02 instead of 0.03 l/min.
What sets this code apart is the combination K1 + FKM + standard electronics at size 1: it is the example the datasheet itself uses to show the type key. Replace F by E and the medium range changes to the EPDM range of -40 to 120 degrees C with standard electronics; replace S by H and the pre-amplifier manages up to 150 degrees C with EPDM or FFKM.
Typical applications of VC 1 K1F1P2SH in Oman and the GCC
Fuel consumption measurement on diesel engines and generator sets is another listed use; VC 1 K1F1P2SH may be wired as a pulse source to a flow computer or PLC counter.
Oil filling and metering stations use the pulse output to batch a set volume; at 1.036 cm3 per tooth chamber each tooth-pass is a tiny portion of the batch.
Cylinder stroke measurement and hydraulic system monitoring are named in the catalogue for the K1 specification, which makes this device a natural fit for presses and clamping tools.
Dosing and ratio control for resins, polyols, isocyanate and adhesives in manufacturing depends on stable counting at low flow; the data sheet names these media for the carbide and stainless-steel versions.
Selection and compatibility notes for VC 1 K1F1P2SH
Pipework: plate mounting (P) onto a connection plate, flow in any direction
Signal chain: 2 sensors with standard pre-amplifier S and Hirschmann appliance socket H; supply 10 to 30 V, square-wave PNP/NPN/push-pull output, IP 65, highest 0.9 W
Select the sealing material from the temperature chart: this combination uses FKM, which together with the electronics returns -15 to 80 degrees C (FKM sealing; the K1 base range is -40 to 210 degrees C).
Flow range: keep the real flow between the lower limit and upper limit of 0.4 to 80 l/min; below the lower figure the pulse accuracy degrades, above the upper figure the pressure loss grows towards the 16 bar permissible limit.
Installation, commissioning and maintenance of VC 1 K1F1P2SH
Fasten the unit to its connection plate or pipe thread with the specified torque and keep the sensor electronics away from heat sources above their rated ambient limit.
Flush the pipework before installation so that particles larger than 20 micrometres do not reach the gears.
Fit VC 1 K1F1P2SH in any position and flow direction; the unit calls for no inlet or outlet straight run, so it matches space-saving skids.
The device has no wearing seals further than the FKM elements, so maintenance is limited to keeping the liquid clean and checking the sensor connector.
Keep a record of the order code VC 1 K1F1P2SH so that spare or replacement meters match the bearing, material, seal and electronics letters precisely.
VC 1 K1F1P2SH FAQ summary
What is the measuring range of KRACHT VC 1 K1F1P2SH? The measuring range for the K1 ball-bearing version of size 1 is 0.4 to 80 l/min, with a starting point of 0.02 l/min.
Which seal does VC 1 K1F1P2SH use? Code F means FKM sealing, so the medium temperature for this device is -15 to 80 degrees C, whatever the wider K1 base range.
How much does VC 1 K1F1P2SH weigh? The catalogue returns 5.2 kg for size 1 in spheroidal cast iron with integrated electronics.
Documents and quotation
The KRACHT VC gear type flow meter data sheet (type key, technical data, electronics, drawings and weights) is supplied with this page as a PDF for VC 1 K1F1P2SH.
Please include VC 1 K1F1P2SH, the required quantity and the destination country in your RFQ; if you hold the old unit, add a picture of its type plate.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Other Models in the Vc Gear Flow Meter Range
Seven Star LLC supplies models from the Vc Gear Flow Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT VC 3 G1E1P2SH Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VC 5 K2K3R2HH Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VC 1 K1F1P5E512 Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VC 12 K3F1P2SH Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VC 0.2 H2E3R2LM Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VC 1 K1F1P2SH Gear Flow Meter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet KRACHT VC 1 K1F1P2SH Gear Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VC 1 K1F1P2SH Gear Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What is the measuring range of KRACHT VC 1 K1F1P2SH?
The measuring range for the K1 ball-bearing version of size 1 is 0.4 to 80 l/min, with a starting point of 0.02 l/min.
02Which seal does VC 1 K1F1P2SH use?
Code F means FKM sealing, so the medium temperature for this meter is -15 to 80 degrees C, whatever the wider K1 base range.
03How much does VC 1 K1F1P2SH weigh?
The datasheet gives 5.2 kg for size 1 in spheroidal cast iron with integrated electronics.
04What resolution does VC 1 K1F1P2SH have?
Standard resolution is 965.25 pulse/l per channel, which can be quadrupled by using both channels with four-fold evaluation.
05What pressure can VC 1 K1F1P2SH handle?
Up to 480 bar for the K1 specification at size 1; the permissible pressure loss across the meter is 16 bar.


















Reviews
There are no reviews yet.