Brand:

KRACHT SVC 40 K1E1S2SH Screw Flow Meter

Description

KRACHT SVC 40 K1E1S2SH overview

KRACHT SVC 40 K1E1S2SH is a KRACHT SVC screw type flow meter: two high-precision screw spindles on rolling-element bearings are turned by the liquid itself, and every pulse corresponds to 5.1300 cm3 passing the instrument in axial direction.

For this size the meter spans 4.0 to 600 l/min with a pulse frequency of 1950 Hz at highest flow; an acoustic level of up to 52 dB(A) retains it quiet in machine halls.

Because the spindles lead the flow straight through the housing, there is no pressure or flow pulsation from the measuring principle and no settling section is needed on either side, so the unit can be installed close to pumps and valves.

With 5.1300 cm3 per pulse the unit covers 4.0 to 600 l/min and offers 194.90 pulse/l at a pulse frequency of 1 950 Hz.

SVC 40 K1E1S2SH features

  • Pulse volume 5.1300 cm3 and 194.90 pulse/l resolution for size 40
  • EPDM sealing with standard electronics: medium temperature -30 to 120 degrees C
  • Measuring range 4.0 to 600 l/min, starting from 0.10 l/min (horizontal) or 0.02 l/min (vertical)
  • Highest pressure of 250 bar in the standard version
  • Very low pressure drop: temporary loss up to 25 bar, permanent up to 7 bar at half of highest flow
  • Housing from spheroidal cast iron EN-GJS-400-15 with heat-treated steel spindles

Technical data of SVC 40 K1E1S2SH

Parameter SVC 40 K1E1S2SH
Manufacturer KRACHT GmbH, Werdohl, Germany
Ordering code SVC 40 K1E1S2SH
Sealing EPDM (code E)
Sensors / electronics 2 sensors, standard pre-amplifier S (24 V), Hirschmann appliance socket H
Pressure loss limit temporary 25 bar, permanent 7 bar at 50 percent of highest flow
Measuring spindles / bearings heat-treated steel, ball bearing
Highest pressure 250 bar (standard version)
Measuring range 4.0 to 600 l/min
Viscosity up to 2 500 000 mm2/s depending on flow
Starting flow 0.10 l/min horizontal, 0.02 l/min vertical mounting
Resolution 194.90 pulse/l (4-fold evaluation 779.70 pulse/l)
Pulse volume 5.1300 cm3 per pulse
Precision up to plus/minus 0.2 percent of measured quantity from 20 mm2/s; repeatability plus/minus 0.05 percent

SVC 40 K1E1S2SH type key by position

Position Code and meaning
SVC screw type flow meter
40 nominal size 40
K ball bearing
1 standard version, spheroidal cast iron EN-GJS-400-15 housing with steel spindles
E EPDM sealing
1 standard coated
S SAE flange
2 2 sensors
S standard pre-amplifier
H Hirschmann appliance socket (standard)

How SVC 40 K1E1S2SH differs from further SVC variants

The SVC range has five nominal sizes, 4, 10, 40, 100 and 250, with pulse volumes of 0.2550, 1.4180, 5.1300, 9.8200 and 18.2500 cm3. SVC 40 K1E1S2SH uses 5.1300 cm3.

Size 10 beside it copes with 1.0 to 150 l/min and 250 bar, whilst SVC 40 K1E1S2SH spans 4.0 to 600 l/min and 250 bar, so the measuring range shifts by a factor of about 3.6.

Size 100 reaches 10.0 to 1 500 l/min with 140 bar; going from SVC 40 K1E1S2SH to that size cuts resolution from 194.90 to 101.80 pulse/l and starting flow rises from 0.10 to 0.15 l/min.

What distinguishes this code is the SAE flange connection (S) in combination with EPDM: size 40 is the only size where the high-pressure version has the same pulse volume of 5.1300 cm3 as the standard version, so the pulse data are identical whereas pressure may differ (250 bar standard, 480 bar high-pressure).

Where SVC 40 K1E1S2SH is employed in Oman and the GCC

Highly viscous products for instance heavy oils, resins and adhesives can be handled since the meter operates up to 2 500 000 mm2/s depending on flow.

Hydraulic test benches and pump test stands use screw meters for their pulsation-free signal and very low pressure loss; resolution of 194.90 pulse/l suits short test cycles.

Fuel-oil and lube-oil consumption on engines, gensets and turbines in the Gulf can be measured with SVC 40 K1E1S2SH over 4.0 to 600 l/min without a straight run upstream.

In process plants, flow may be reported to a PLC through the pulse output, a 4 to 20 mA analogue version or an IO-Link version, depending on the electronics letter in the code.

Selection and compatibility notes for SVC 40 K1E1S2SH

Signal chain: 2 sensors, standard pre-amplifier S (24 V), Hirschmann appliance socket H; supply voltage and connector are fixed by the last letters of the code.

Flow window: stay within 4.0 to 600 l/min, since the data sheet derives resolution and pulse frequency from that range.

Mounting orientation matters only for the starting flow: 0.10 l/min horizontal against 0.02 l/min vertical.

Connection SAE flange: SAE flanges bolt onto SAE-standard pipe flanges, saving threaded adapters.

Installation and commissioning of SVC 40 K1E1S2SH

Wire the pre-amplifier per the data sheet pin assignment and check that the counter can follow 1950 Hz at highest flow.

Commission by comparing the counted pulses against a reference volume; a DAkkS-traceable calibration with a measurement accuracy characteristic can be requested.

Flush the line before fitting the meter and consider a filter ahead of it, since the screw spindles are precision parts.

Maintenance of SVC 40 K1E1S2SH

Note the code SVC 40 K1E1S2SH from the nameplate when asking for a replacement so that the bearing, seal and electronics letters match.

If readings drift, check for air in the line and compare with a reference at the same viscosity.

SVC 40 K1E1S2SH FAQ summary

What flange does KRACHT SVC 40 K1E1S2SH have? Code S means SAE flange connections.

What is the flow range of SVC 40 K1E1S2SH? 4.0 to 600 l/min with a starting flow of 0.10 l/min horizontal and 0.02 l/min vertical.

What is the temperature range of SVC 40 K1E1S2SH? -30 to 120 degrees C with EPDM sealing and standard electronics.

Documents and quotation

Use the attached KRACHT SVC screw type flow meter catalogue PDF, which contains the type key, operating parameters, electronics and drawings, when you check SVC 40 K1E1S2SH against your drawing.

To request a quotation, send an RFQ that names the exact code SVC 40 K1E1S2SH, the quantity and the delivery place in Oman or the GCC. A photo of the name plate supports us verify each code position.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Other Models in the Svc Screw Flow Meter Range

Seven Star LLC supplies models from the Svc Screw Flow Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
KRACHT SVC 100 K1F1D2HH Screw Flow MeterTurbine & Positive Displacement FlowmetersView details
KRACHT SVC 250 K1L1D2SH Screw Flow MeterTurbine & Positive Displacement FlowmetersView details
KRACHT SVC 10 K1F1R2SH Screw Flow MeterTurbine & Positive Displacement FlowmetersView details
KRACHT SVC 40 K1E1S2SH Screw Flow MeterTurbine & Positive Displacement FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet KRACHT SVC 40 K1E1S2SH Screw Flow Meter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.

Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.

KRACHT company profile

Founded 1911, registered as Hillebrand & Kracht OHG
Headquarters Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971
Ownership Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company
Size About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco
Subsidiaries USA, China and Hungary (KRACHT Hidraulik Kft.)
Product families External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders

Milestones

  • 1911: Hillebrand & Kracht OHG is entered in the trade register.
  • 1971: The company moves into its present premises in Werdohl.
  • 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
  • 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.

KRACHT pumps, flow meters and valves listed

The listing follows four product groups, pumps, fluid measurement, valves and drives:

  • Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
  • Fluid measurement technology: gear type flow meters such as the VCA in aluminum
  • Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
  • Drive technology: KM hydraulic gear motors

Where KRACHT equipment is used

KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.

KRACHT products we list

Family Examples
Pumps BT / BTH Low-Speed Gear Pump, DT DuroTec Gear Pump for Abrasive Fluids, KD1 Gear Metering Pump, KF 0 Stainless Steel Process Gear Pump, KF Series Modular Gear Pump, KF-F Fuel Gear Pump Series, KF80RF2-D15 Gear Pump, KM Series Hydraulic Gear Motor and 2 more
Flowmeters Fluid Measurement Technology Series, SVC Screw Type Flow Meter, TM Turbine Flow Meter, VC 0.01 Micro Gear Type Flow Meter, VC Gear Type Flow Meter, VCA Aluminum Gear Flow Meter, VCM Gear Flow Meter
Safety Relief Valves DBD Directly Controlled Poppet Valve, DV B Hydraulically Pilot Controlled Valve, HV/HVF Pilot Operated Slide Valve, SPV 10 L1G 1 A 12 Pressure Relief Valve, SPV/SPVF Directly Controlled Slide Valve, Valve Technology Series
Hydraulic Valves & Components CNL Hydraulic Cylinder, DV S Pressure Stage Control Valve
Gear Units & Reducers Drive Technology Series

Ordering KRACHT parts: what we need

KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.

Frequently requested KRACHT models: KRACHT Pump Technology Series.

Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.

FAQ

Questions about the KRACHT SVC 40 K1E1S2SH Screw Flow Meter

Answers from our engineering team on installation, compatibility and integration.

01What flange does KRACHT SVC 40 K1E1S2SH have?
Code S means SAE flange connections. This is taken from the KRACHT datasheet for SVC 40 K1E1S2SH.
02What is the flow range of SVC 40 K1E1S2SH?
4.0 to 600 l/min with a starting flow of 0.10 l/min horizontal and 0.02 l/min vertical.
03What is the temperature range of SVC 40 K1E1S2SH?
-30 to 120 degrees C with EPDM sealing and standard electronics.
04What is the resolution of SVC 40 K1E1S2SH?
194.90 pulse/l, or 779.7 pulse/l with 4-fold evaluation, with a pulse volume of 5.1300 cm3.
05What is the pressure rating of SVC 40 K1E1S2SH?
250 bar in the standard version. This is taken from the KRACHT datasheet for SVC 40 K1E1S2SH.