Description
Direction detection in a compact meter: VCA 0.2 U5F4R2SH
KRACHT VCA 0.2 U5F4R2SH is the only size in the VCA family that combines a plastic plain bearing with two sensors. The two channels are offset by 90 degrees plus/minus 30, so the evaluating electronics can tell which way the oil flows and count four edges per tooth instead of one.
The ordering code reads VCA 0.2, U plastic plain bearing, 5 aluminium housing with steel gears, F FKM seals, 4 hard-coated surface, R pipe connection, 2 two sensors, S standard pre-amplifier and H Hirschmann socket.
Compared with a single-channel meter the extra sensor costs very little in installation effort, because both channels leave through the same plug. The advantage is robustness against sensor noise: if a counter sees both channels change in a consistent order, spurious pulses caused by vibration at standstill can be ignored, which is helpful on machines where the oil column oscillates when a pump stops.
Technical data of VCA 0.2 U5F4R2SH
| Parameter | Value |
|---|---|
| Type code | VCA 0.2 U5F4R2SH |
| Geometric tooth volume | 0.200 cm3 |
| Measuring range | 0.25 to 10 l/min |
| Measuring unit starting at | 0.04 l/min at 100 mm2/s |
| Resolution per channel | 5,000.00 pulses per litre |
| Maximum pressure | 200 bar |
| Maximum pressure loss | 10 bar |
| Weight | 0.6 kg |
| Channels | 2, offset 90 degrees plus/minus 30 |
| Typical accuracy | plus/minus 1.0 percent from 20 mm2/s |
| Media and ambient temperature | -10 to 80 C |
| Viscosity | up to 4,000 mm2/s |
| Supply | 12 to 30 V DC |
| Output | PNP / NPN square wave |
| Protection | IP 65 |
The datasheet also gives pressure drop curves with viscosity as the parameter. For this size the curve family runs up to 10 l/min, so check your oil’s viscosity at its coldest operating temperature against the chart before finalising the line pressure.
Differences between VCA 0.2 U5F4R2SH and other VCA models
Two numbers separate it from the VCA 0.1: the pressure loss limit is 10 bar rather than 16 bar and the maximum pressure is 200 bar rather than 240 bar. The start-up flow of 0.04 l/min is quoted at 100 mm2/s because the plastic plain bearing is meant for thicker oil, whereas the ball-bearing sizes quote 20 mm2/s.
Against the VCA 2 it has the same 200 bar rating and 0.6 kg weight class but a range ten times smaller (10 versus 65 l/min) and a resolution ten times larger (5,000 versus 500 pulses per litre).
Using the two channels of VCA 0.2 U5F4R2SH
Pin 2 carries channel 1 (green) and pin 3 carries channel 2 (yellow); pin 1 is supply (brown) and pin 4 is 0 V (white). When the flow reverses, the order in which the two pulse trains appear flips, which is the information a counter needs to subtract reverse volume from forward volume.
With 4-fold evaluation every rising and falling edge of both channels is used, so the effective resolution climbs to four times the standard 5,000 pulses per litre. Standard evaluation uses only the rising edge of channel I.
On a positioning rig, the controller can integrate the signed pulse count to derive the piston travel indirectly, because a known volume of oil corresponds to a known stroke. The VCA 0.2 offers enough resolution for that task and the dual-channel signal supplies the sign, which is the reason hydraulic test engineers specify it.
Where VCA 0.2 U5F4R2SH fits in Oman and GCC plants
Reciprocating drives, hydraulic cylinders and positioning rigs often move oil back and forth, and a unidirectional meter would add both directions together. A dual-channel gear meter solves that, and it is also valued on lubricant return lines and test stands where flow reversal occurs during cycling.
The aluminium housing keeps weight low for machine-mounted installations, while the pipe connection simplifies integration into tubing.
It also suits fuel return lines of diesel engines where the difference between supply and return flow is the consumption, and the direction information keeps the totals honest if the return line backflows during shutdown.
Selection notes for VCA 0.2 U5F4R2SH
Use clean oil within 4,000 mm2/s. The datasheet describes the plastic plain bearing for this nominal size only; if the oil is very thin or the process needs high precision at the low end, the ball bearing sizes 0.04 and 0.1 are better. Check the 10 bar pressure-loss limit against your viscosity chart.
ATEX/IECEx versions exist in the product line; confirm with your supplier if a hazardous area applies.
The plastic plain bearing is intended for lubricating media and gives a quieter, more tolerant operation with contaminated oil than a ball bearing, but it should not be used with media that attack the plastic. When in doubt, send the medium data to the supplier with your RFQ.
Installing VCA 0.2 U5F4R2SH
Mount in any position and in any flow direction. Connect the pipe thread, route the cable away from power cables to keep the square-wave signals clean, and verify with a scope or counter that both channels pulse while the oil flows. A load per channel of 0.3 W is short-circuit protected.
Label both signal wires clearly at the terminal. A common commissioning error is swapping the channels, which makes the forward direction count negative; if this happens, exchange the two wires or invert the direction in the counter configuration.
Service and ordering
Keep the filter in good condition and record the counter against a reference at intervals. Related models: VCA 0.1 K5F4R1SH and VCG 2 M1F1P2SH, which share the two-channel concept.
Because there are two independent channels, a failed sensor can be diagnosed quickly: if one channel pulses and the other does not, the pre-amplifier or sensor in the plug is the likely culprit rather than the gears.
Documents and quotation
The datasheet is attached to this page. Send VCA 0.2 U5F4R2SH with your quantity as an RFQ to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Other Models in the Kracht Vca Gear Range
Seven Star LLC supplies models from the Kracht Vca Gear range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10 l/min | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.2 U5F4R2SH Dual-Channel Gear Flow Meter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
| KRACHT VCA 2 M4F4P1SH Plate-Mounted Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 5 K5F4R1SH Gear Flow Meter up to 200 l/min | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350 bar | Turbine & Positive Displacement Flowmeters | View details |
Datasheets & Documents
- Datasheet KRACHT VCA 0.2 U5F4R2SH Dual-Channel Gear Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VCA 0.2 U5F4R2SH Dual-Channel Gear Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What range does KRACHT VCA 0.2 U5F4R2SH measure?
0.25 to 10 l/min, with the unit starting at 0.04 l/min at a viscosity of 100 mm2/s.
02Can VCA 0.2 U5F4R2SH detect flow direction?
Yes, the 2 in the code selects two sensors with a 90 degree offset, and the datasheet describes dual-channel output for the VCA 0.2.
03What is the pressure rating of VCA 0.2 U5F4R2SH?
Maximum pressure is 200 bar and the maximum permissible pressure loss is 10 bar.
04Which bearing does VCA 0.2 U5F4R2SH use?
A plastic plain bearing, code U, which the datasheet offers only for nominal size 0.2.
05What is the resolution of VCA 0.2 U5F4R2SH?
5,000.00 pulses per litre per channel, rising to four times that with 4-fold evaluation.