Brand: KRACHT
KRACHT SVC 100 K1F1D2HH Screw Flow Meter
Description
KRACHT SVC 100 K1F1D2HH overview
KRACHT SVC 100 K1F1D2HH is a KRACHT SVC screw type flow meter: two high-precision screw spindles on rolling-element bearings are turned by the liquid itself, and every pulse corresponds to 9.8200 cm3 passing the instrument in axial direction.
Because the spindles lead the flow straight through the housing, there is no pressure or flow pulsation from the measuring principle and no settling section is needed on either side, so the instrument may be installed close to pumps and valves.
All moving parts are lubricated by the measured medium. The instrument tolerates viscosities up to 2 500 000 mm2/s, depending on flow, with common accuracy of plus or minus 0.2 percent from 20 mm2/s.
With DIN flanges and the high-temperature pre-amplifier this size 100 meter is meant for hot fuel or lube oil lines up to 150 degrees C.
SVC 100 K1F1D2HH features
- Highest pressure of 140 bar in the standard version
- Measuring range 10.0 to 1 500 l/min, starting from 0.15 l/min (horizontal) or 0.03 l/min (vertical)
- Housing from spheroidal cast iron EN-GJS-400-15 with heat-treated steel spindles
- FKM with high-temperature electronics: medium temperature -30 to 150 degrees C
- Electronics: 2 sensors, high-temperature pre-amplifier H (24 V, media up to 150 degrees C), Hirschmann appliance socket H
- Very low pressure drop: temporary loss up to 25 bar, permanent up to 7 bar at half of highest flow
Technical data of SVC 100 K1F1D2HH
| Parameter | SVC 100 K1F1D2HH |
|---|---|
| Pressure loss limit | temporary 25 bar, permanent 7 bar at 50 percent of highest flow |
| Pulse frequency at Qmax | 2546 Hz |
| Precision | up to plus/minus 0.2 percent of measured quantity from 20 mm2/s; repeatability plus/minus 0.05 percent |
| Series | SVC screw type flow meter, nominal size 100 |
| Manufacturer | KRACHT GmbH, Werdohl, Germany |
| Resolution | 101.80 pulse/l (4-fold evaluation 407.30 pulse/l) |
| Sensors / electronics | 2 sensors, high-temperature pre-amplifier H (24 V, media up to 150 degrees C), Hirschmann appliance socket H |
| Pulse volume | 9.8200 cm3 per pulse |
| Order code | SVC 100 K1F1D2HH |
| Measuring range | 10.0 to 1 500 l/min |
| Medium temperature (this combination) | -30 to 150 degrees C (FKM with high-temperature pre-amplifier H) |
| Viscosity | up to 2 500 000 mm2/s depending on flow |
| Pressure limit | 140 bar (standard version) |
SVC 100 K1F1D2HH type key by position
| Position | Code and meaning |
|---|---|
| SVC | screw type flow meter |
| 100 | nominal size 100 |
| K | ball bearing |
| 1 | standard version, spheroidal cast iron EN-GJS-400-15 housing with steel spindles |
| F | FKM sealing |
| 1 | standard coated |
| D | DIN flange |
| 2 | 2 sensors |
| H | high-temperature pre-amplifier |
| H | Hirschmann appliance socket (standard) |
How SVC 100 K1F1D2HH differs from further SVC variants
The SVC range has five nominal sizes, 4, 10, 40, 100 and 250, with pulse volumes of 0.2550, 1.4180, 5.1300, 9.8200 and 18.2500 cm3. SVC 100 K1F1D2HH uses 9.8200 cm3.
Size 40 beside it manages 4.0 to 600 l/min and 250 bar, whereas SVC 100 K1F1D2HH spans 10.0 to 1 500 l/min and 140 bar, so the measuring range shifts by a factor of about 1.9.
Size 250 reaches 25.0 to 3 750 l/min with 40 bar; going from SVC 100 K1F1D2HH to that size cuts resolution from 101.80 to 54.80 pulse/l and starting flow rises from 0.15 to 0.90 l/min.
Size 100 is designed for 140 bar only, against 250 bar for sizes 10 and 40, and has no high-pressure version. The H electronics raise the medium ceiling from 120 degrees C (standard S) to 150 degrees C.
Where SVC 100 K1F1D2HH is used in Oman and the GCC
Transfer and loading lines that run near the 140 bar limit of the standard version can use the instrument directly as the measuring principle causes only a very low pressure drop.
Fuel-oil and lube-oil consumption on engines, gensets and turbines in the Gulf can be measured with SVC 100 K1F1D2HH over 10.0 to 1 500 l/min without a straight run upstream.
Highly viscous products including heavy oils, resins and adhesives may be handled since the device functions up to 2 500 000 mm2/s depending on flow.
In process plants, flow may be reported to a PLC through the pulse output, a 4 to 20 mA analogue version or an IO-Link version, depending on the electronics letter in the code.
Selection and compatibility notes for SVC 100 K1F1D2HH
Pressure limit 140 bar, permanent pressure loss up to 7 bar at 50 percent of highest flow, and temporary loss up to 25 bar.
Connection DIN flange: DIN flanges connect to DIN-standard pipework used in European-style process plants.
Sealing FKM combined with the electronics offers -30 to 150 degrees C (FKM with high-temperature pre-amplifier H); check that against the medium and the line temperature before ordering.
Mounting orientation matters only for the starting flow: 0.15 l/min horizontal against 0.03 l/min vertical.
Installation and commissioning of SVC 100 K1F1D2HH
Flush the line before fitting the instrument and consider a filter ahead of it, as the screw spindles are precision parts.
Install SVC 100 K1F1D2HH with the connection DIN flange; no inlet or outlet straight lengths are needed and the unit may be mounted in any position.
Wire the pre-amplifier per the catalogue pin assignment and check that the counter can follow 2546 Hz at highest flow.
Maintenance of SVC 100 K1F1D2HH
If readings drift, check for air in the line and compare with a reference at the same viscosity.
Maintenance is limited to keeping the medium clean and checking the connector and FKM sealing for leaks.
SVC 100 K1F1D2HH FAQ summary
What is the pressure rating of KRACHT SVC 100 K1F1D2HH? 140 bar.
What is the flow range of SVC 100 K1F1D2HH? 10.0 to 1 500 l/min with a starting flow of 0.15 l/min horizontal.
How hot can the medium be for SVC 100 K1F1D2HH? Up to 150 degrees C with FKM sealing and the high-temperature pre-amplifier.
Documents and quotation
A PDF copy of the KRACHT SVC screw type flow meter catalogue is attached to this listing; it spans type key, operating parameters, electronics and drawings relevant to SVC 100 K1F1D2HH.
Please include SVC 100 K1F1D2HH, the required quantity and the destination country in your RFQ; if you hold the old unit, add a picture of its type plate.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Other Models in the Svc Screw Flow Meter Range
Seven Star LLC supplies models from the Svc Screw Flow Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT SVC 100 K1F1D2HH Screw Flow Meter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
| KRACHT SVC 250 K1L1D2SH Screw Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT SVC 10 K1F1R2SH Screw Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
Datasheets & Documents
- Datasheet KRACHT SVC 100 K1F1D2HH Screw Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT SVC 100 K1F1D2HH Screw Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What is the pressure rating of KRACHT SVC 100 K1F1D2HH?
140 bar. This is taken from the KRACHT datasheet for SVC 100 K1F1D2HH.
02What is the flow range of SVC 100 K1F1D2HH?
10.0 to 1 500 l/min with a starting flow of 0.15 l/min horizontal.
03How hot can the medium be for SVC 100 K1F1D2HH?
Up to 150 degrees C with FKM sealing and the high-temperature pre-amplifier.
04What connection does SVC 100 K1F1D2HH have?
DIN flanges (code D). This is taken from the KRACHT datasheet for SVC 100 K1F1D2HH.
05What is the pulse volume of SVC 100 K1F1D2HH?
9.8200 cm3 per pulse, giving 101.80 pulse/l.


















Reviews
There are no reviews yet.