Brand: KRACHT
KRACHT VCA 2 M4F4P1SH Plate-Mounted Gear Flow Meter
Description
KRACHT VCA 2 M4F4P1SH as a manifold-mounted flow meter
KRACHT VCA 2 M4F4P1SH is the plate-mounting version of the VCA size 2: instead of screwing tubes into the body, the meter is bolted onto a connection plate or a hydraulic block, which is how hydraulic power units and test stands are built. It measures 1.00 to 65 l/min with a tooth chamber volume of 2.000 cm3 and delivers 500 pulses per litre.
The code resolves to VCA 2 (size 2), M (multi-layer plain bearing), 4 (aluminium housing with stainless steel gears), F (FKM seals), 4 (hard-coated surface), P (plate mounting), 1 (single sensor), S (standard pre-amplifier) and H (Hirschmann socket).
Technical specification of VCA 2 M4F4P1SH
| Parameter | Value |
|---|---|
| Type code | VCA 2 M4F4P1SH |
| Geometric tooth volume | 2.000 cm3 |
| Measuring range | 1.00 to 65 l/min |
| Measuring unit starting at | 0.04 l/min at 100 mm2/s |
| Resolution | 500.00 pulses per litre |
| Maximum pressure | 200 bar |
| Weight | 1.9 kg |
| Plate mounting tightening torque | 13 Nm |
| Bearing | Multi-layer plain bearing |
| Housing / gears | Aluminium / stainless steel |
| Typical accuracy | plus/minus 1.0 percent from 20 mm2/s |
| Maximum pressure loss | 16 bar |
| Viscosity | up to 4,000 mm2/s |
| Media and ambient temperature | -10 to 80 C |
| Sound pressure level | up to 60 dB(A) |
| Supply | 12 to 30 V DC, PNP / NPN |
| Protection | IP 65 |
Position of VCA 2 M4F4P1SH within the VCA range
Size 2 is one of only two VCA sizes, together with 0.2, for which the type key offers plate mounting alongside the pipe thread. At 1.9 kg it is more than three times heavier than the VCA 0.2 yet only a third of the weight of the VCA 5 at 6.0 kg. The pressure rating of 200 bar matches the VCA 0.2, while the VCA 5 carries only 100 bar.
The pulse density of 500 per litre is far lower than the 5,000 of the VCA 0.2, which is the trade-off of the larger tooth chamber, so for slow flows the pulse rate is lower. The cast iron cousin of this meter, the VCG 2, offers the same 1.00 to 65 l/min range but a 350 bar rating and two sensors.
On a practical level, the plate version saves tubing and leak points, which is attractive for compact skid builders in the Gulf where space inside enclosures is limited and every threaded joint is a potential weeping point under thermal cycling.
Applications for VCA 2 M4F4P1SH
Plate mounting suits hydraulic power packs, lubrication skids and component test benches where the meter sits on a manifold between pump and consumer. Typical Omani and GCC uses include hydraulic press testing, gearbox and pump end-of-line testing at workshops, and oil consumption monitoring on diesel generators.
Because it is a displacement meter it does not need inlet and outlet straight runs, which saves space on compact skids.
A concrete example is an end-of-line test of a hydraulic pump after repair. The pump is run on a test bench at several speeds, and the meter on the delivery manifold records the volume per revolution. At 65 l/min the VCA 2 covers pumps of moderate size, and its 500 pulses per litre mean that a one-second gate on the counter resolves roughly 8 pulses at the top of the range and about half a pulse at the 1 l/min bottom, so a longer gate is used at low flow.
In lubrication systems, the same meter verifies that a circulating oil supply to a turbine or compressor train delivers the commissioning flow. A total of delivered oil, stored by the PLC, shows when the reservoir has to be topped up and provides a basis for oil consumption benchmarking between machines on a site.
Selection and compatibility
The multi-layer plain bearing is intended for lubricating oils. Check viscosity against the pressure loss chart; the limit is 16 bar. The meter can be mounted in any position and accepts any flow direction, but a single sensor will not report direction, so use two-sensor types when you need it. If the plant is in a hazardous area, ask for an ATEX/IECEx version.
The datasheet notes that a pipe connection with G1 dimension is also offered for size 2, so confirm plate versus pipe when you place an order.
The starting flow of 0.04 l/min is quoted at 100 mm2/s. Thinner oil will leak slightly past the gears at very low flow, which explains why accuracy is quoted from 20 mm2/s upward. If your process runs at low viscosity and low flow, discuss the duty with the supplier before choosing this size.
Mounting VCA 2 M4F4P1SH on a plate
Prepare a flat, clean connection plate with the correct port pattern and O-rings, place the meter, and tighten the screws with a torque wrench to 13 Nm. Wire the Hirschmann socket: pin 1 supply (brown), pin 2 channel 1 (green), pin 4 0 V (white), pin 3 unused. A supply of 12 to 30 V DC is allowed, reverse polarity protected.
Run the system at low pressure first, vent the air and watch that pulses appear. Verify the pulse constant of 500 per litre in the controller.
Use new O-rings on the connection plate at each refit and keep the sealing faces free from scratches. Because the meter is aluminium, avoid over-tightening and follow the 13 Nm figure. Connect the cable so that its entry points downward to keep condensation out of the plug.
Maintenance routine
Replace the filter element on schedule, check the plug seal for IP 65 integrity and compare the totaliser against a reference after major oil changes. Unusual noise above the 60 dB(A) class or a rising start-up flow suggests wear.
Ordering and related
Quote VCA 2 M4F4P1SH with quantity. Related: VCA 0.2 U5F4R2SH, VCA 5 K5F4R1SH and VCG 2 M1F1P2SH.
Documents and quotation
The datasheet is attached. Send an RFQ for VCA 2 M4F4P1SH to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Other Models in the Kracht Vca Gear Range
Seven Star LLC supplies models from the Kracht Vca Gear range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT VCA 0.04 K4F4R1SH Micro Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.1 K5F4R1SH Gear Flow Meter 0.08-10 l/min | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 0.2 U5F4R2SH Dual-Channel Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCA 2 M4F4P1SH Plate-Mounted Gear Flow Meter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
| KRACHT VCA 5 K5F4R1SH Gear Flow Meter up to 200 l/min | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350 bar | Turbine & Positive Displacement Flowmeters | View details |
Datasheets & Documents
- Datasheet KRACHT VCA 2 M4F4P1SH Plate-Mounted Gear Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VCA 2 M4F4P1SH Plate-Mounted Gear Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What range does KRACHT VCA 2 M4F4P1SH measure?
1.00 to 65 l/min with a measuring unit starting at 0.04 l/min at 100 mm2/s.
02How is VCA 2 M4F4P1SH mounted?
The P in the code means plate mounting, tightened with a torque of 13 Nm on a connection plate or manifold.
03What is the pulse resolution of VCA 2 M4F4P1SH?
500.00 pulses per litre for the tooth volume of 2.000 cm3.
04What pressure can VCA 2 M4F4P1SH withstand?
Maximum pressure is 200 bar with a maximum permissible pressure loss of 16 bar.
05How heavy is VCA 2 M4F4P1SH?
It weighs 1.9 kg with its aluminium housing and stainless steel gears.


















Reviews