Description
KRACHT TM 34 H F 040 L summary
KRACHT TM 34 H F 040 L is a DN40 flanged turbine flow meter that speaks IO-Link. Nominal size 34 gives a maximum flow of 34 m3/h, carbide bearings handle clean thin liquids from 113.0 to 566.67 l/min, and the L electronics report measured values with units to an IO-Link master while still falling back to square-wave pulses in SIO mode.
That dual personality is the selling point. The meter can serve a classic PLC counter input or a modern IO-Link infrastructure without exchanging hardware.
Specification of TM 34 H F 040 L
| Parameter | Value |
|---|---|
| Type code | TM 34 H F 040 L |
| Nominal size | 34 (34 m3/h) |
| Flange | DN40, bore 37 mm |
| Measuring range, carbide | 113.0 to 566.67 l/min |
| Typical accuracy | plus/minus 0.5 percent |
| Length | 179.0 mm |
| Dimension C | 90.0 mm |
| Weight | 6.20 kg |
| Pressure stage | 040, up to 40 bar |
| Media temperature, IO-Link | -40 to 80 C |
| Ambient temperature, IO-Link | -40 to 50 C, higher on request |
| Supply voltage | 10 to 30 V DC |
| Signal output | Push-pull, up to 25 mA |
| Power requirement | maximum 2 W |
| IO-Link manufacturer ID | 0x0524 |
| IO-Link device ID | 0x000001 |
| Bit rate | COM3, 230.4 kbit/s |
| Minimum cycle time | 500 microseconds |
| Protection | IP 65 |
IO-Link functions of TM 34 H F 040 L
IO-Link is standardised in IEC 61131-9 and gives a point-to-point connection with continuous monitoring from the control level down to the meter. Commissioning is simplified by the IODD (IO Device Description) file, which describes the device parameters to the master.
In IO-Link mode the module outputs the measured values directly with their units, for example the pulse count and volume in litres, so the controller no longer needs scaling constants. The device reports IO-Link version V1.1, supports SIO mode, indexed service data and data storage, which allows a replacement meter to inherit its parameters automatically.
If no IO-Link master has activated the link, the meter works in SIO mode and emits the same two-state-change square wave as a standard pre-amplifier, at an amplitude of at least supply voltage minus 2 V for high and at most 2 V for low.
How TM 34 H F 040 L differs from other TM variants
The flange size distinguishes the family: DN20 for size 8, DN25 for size 16, DN40 here and DN50 for size 68. Within these, the TM 34 H F 040 L is distinguished by its IO-Link electronics, which lower the permissible media temperature to 80 C and the ambient temperature to 50 C compared with 120 C and 80 C for the standard pulse version.
Against the TM 16 T F 040 A its range is more than twice as large and the bearings are carbide, which lifts the minimum from 26.7 to 113.0 l/min. Against the TM 68 H F 040 S it is about a half of the capacity, 2.1 kg lighter at 6.20 kg versus 8.30 kg, and 19 mm shorter.
Use of TM 34 H F 040 L in plants in the GCC
A 34 m3/h turbine suits transfer lines for diesel, light fuel oil, water and cooling media. The IO-Link link is attractive in modular skid builds, where the master sits in a distributed I/O cabinet and the machine builder wants parameter backup and diagnostics from the same cable.
Process industries in Oman use such meters for blending lines, additive dosing in refineries, and utility metering in water treatment and power stations when a stainless, low-maintenance meter is required.
Because the electronics are limited to 50 C ambient, outdoor installations in the Gulf summer should be shaded or the manufacturer should be asked about the higher-temperature option mentioned in the datasheet.
Selection and installation of TM 34 H F 040 L
Plan for 6.20 kg of weight, supporting the pipe. Install horizontally within plus/minus 5 degrees with correct flow direction, keep to the maximum 40 bar and allow for the flow-calming sections that the manufacturer prescribes.
Wire the four-pole M12x1: pin 1 brown, pin 2 white, pin 3 blue, pin 4 black. Load the IODD in the master, check that the meter is in IO-Link mode and verify the first volume reading against a reference. Keep ambient temperature below 50 C.
The connection plug carries two LEDs, L1 in green and L2 in red, whose flashing patterns show the IO-Link state and the channel 1 status. A quick glance at the plug therefore tells the electrician whether the master has taken over the link before anyone opens the controller. Keep the IODD file with the commissioning records so that a later technician can restore the parameter set.
Maintenance and replacement for TM 34 H F 040 L
Carbide bearings give long life in clean media. Because IO-Link supports data storage, replacing the meter during a shutdown can be as simple as plugging in an identical code and allowing the master to restore parameters.
Related products and FAQ summary
Neighbours in the series: TM 16 T F 040 A, TM 68 H F 040 S and TM 8 H F 040 S. Quote TM 34 H F 040 L in full when sending your RFQ, because the last letter decides the electronics. If the plant standard is IO-Link, ask whether the same size is needed in several lines so that spare meters can be rationalised, and confirm the DN40 counter flanges and gaskets at the same time.
Documents and quotation
The KRACHT TM datasheet is attached. For TM 34 H F 040 L send an RFQ with quantity to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Ordering Checklist for the KRACHT TM 34 H F 040 L
Before you ask for a quotation for the KRACHT TM 34 H F 040 L, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the turbine & positive displacement flowmeters already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.
Installation and Commissioning Planning
Planning ahead shortens downtime when a KRACHT TM 34 H F 040 L goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the KRACHT equipment can be planned around it.
Other Models in the Kracht Tm Turbine Range
Seven Star LLC supplies models from the Kracht Tm Turbine range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT TM 1.1 H R 320 A Turbine Flow Meter 4-20 mA | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 4 T R 320 S Turbine Flow Meter PTFE Bearing | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 8 H F 040 S Flanged Turbine Flow Meter DN20 | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 16 T F 040 A Turbine Flow Meter DN25 4-20 mA | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 34 H F 040 L IO-Link Turbine Flow Meter DN40 | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet KRACHT TM 34 H F 040 L IO-Link Turbine Flow Meter DN40 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT TM 34 H F 040 L IO-Link Turbine Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What does the L in KRACHT TM 34 H F 040 L mean?
L selects the IO-Link electronic version, which calculates measured values internally and can also run as a pulse output in SIO mode.
02What is the measuring range of TM 34 H F 040 L?
With carbide bearings, nominal size 34 covers 113.0 to 566.67 l/min at plus/minus 0.5 percent typical accuracy.
03What IO-Link data does TM 34 H F 040 L report?
The datasheet lists manufacturer ID 0x0524, device ID 0x000001, IO-Link V1.1, COM3 at 230.4 kbit/s and a minimum cycle time of 500 microseconds.
04What are the temperature limits of TM 34 H F 040 L?
For the IO-Link version media temperature is -40 to 80 C and ambient is -40 to 50 C, with higher ambient temperatures on request.
05Which flange does TM 34 H F 040 L have?
A DN40 flange in the 040 stage for pressures up to 40 bar, 179.0 mm long and 6.20 kg in weight.