KRACHT TM 8 H F 040 S at a glance

KRACHT TM 8 H F 040 S is the first flanged turbine in the TM line: a DN20 flange connection, a 40 bar pressure stage, carbide bearings and standard square-wave electronics, measuring 26.6 to 133.33 l/min of thin liquid. Nominal size 8 means a maximum flow of 8 m3/h.

The flange makes the difference for plant engineers. Instead of a threaded pipe fitting you get a body of 141 mm length and 2.60 kg that bolts between normal flanged pipework in utility and process lines, which is how most Gulf facilities lay out water, fuel and chemical headers.

The turbine is built around a rotor that turns in proportion to the flow, and the housing, flanges and rotor are stainless steel 1.4541 (X6CrNiTi18-10). Output goes out as square-wave pulses through the integrated pre-amplifier.

Technical specification of TM 8 H F 040 S

Parameter Value
Type code TM 8 H F 040 S
Nominal size 8 (8 m3/h)
Flange DN20, nominal bore 18 mm
Pressure stage 040, up to 40 bar
Measuring range, carbide 26.6 to 133.33 l/min
Measuring range, PTFE alternative (size 8) 13.3 to 133.33 l/min
Typical accuracy plus/minus 0.5 percent
Length 141 mm
Dimension C 80.0 mm
Weight 2.60 kg
Housing, flanges, rotor Stainless steel 1.4541
Bearings Carbide
Supply 10 to 30 V DC
Output PNP / NPN / push-pull square wave
Media temperature -40 to 120 C
Viscosity 1.0 to 50 mm2/s
Protection IP 65

Design and key features of TM 8 H F 040 S

A turbine rotor sits concentrically in the housing between a front stator and a rear stator. Flow turns the rotor in proportion to throughput; the sensor converts the passage into pulses and the pre-amplifier shapes them into a square wave of at least 80 percent of supply voltage, with a duty factor of 50 percent plus/minus 15.

KRACHT lists a large measuring range, a very low pressure drop, a high working pressure and low noise emission as the benefits of the series. The model is not bidirectional, and the flow direction is marked on the housing.

Differences between TM 8 H F 040 S and its neighbours

Against the size 16 flanged turbine (DN25, 153.5 mm long, 3.70 kg, 53.4 to 266.67 l/min) the TM 8 is smaller and lighter. Against the size 4 pipe-connection version (15 mm bore, 66.67 l/min, 0.25 kg) it handles roughly double the flow and uses a flange rather than an M30x2 thread.

The pressure stage also changes with the connection: pipe meters offer 320 bar, flanged meters carry the 040 stage only. Carbide bearings raise the bottom of the range to 26.6 l/min, whereas the PTFE alternative at this size reaches down to 13.3 l/min, so a low-flow duty may justify the T version instead.

Use cases for TM 8 H F 040 S in industry

A DN20 turbine at 133 l/min is common on cooling water injection, fuel oil transfer at small power plants, chemical feed and filling machines. Its square wave can feed batching controllers and flow totalisers used in water and wastewater plants and in manufacturing across the GCC.

It is not a meter for slurries, heavy oil or media with fibres. Stay inside the viscosity window of 1.0 to 50 mm2/s.

In Oman, a meter of this size is often specified on skid packages that must report consumption of diesel, lube oil or cooling water back to a plant controller, and where the buyer wants a compact stainless body that survives the ambient heat of an outdoor skid. The standard electronics tolerate ambient temperatures from -40 to 80 C, which covers desert installations when the housing is shaded.

Selection checks before ordering TM 8 H F 040 S

  • Viscosity 1.0 to 50 mm2/s and density 500 to 1500 kg/m3
  • Foreign matter at most 50 g per cubic metre, particles under 500 micrometres, hardness up to 100 HB
  • Maximum pressure 40 bar for this flange stage
  • Media at -40 to 120 C, ambient -40 to 80 C
  • Horizontal installation within plus/minus 5 degrees

If any of these fall outside, the datasheet recommends consulting the manufacturer or choosing another measuring principle.

Fitting and starting TM 8 H F 040 S

Place the DN20 flanges with matching gaskets and flow-calming pipe lengths, observe the arrow, and fill the line gently. On the four-pole M12 connector, supply is on pin 1 (brown), channel 1 on pin 2 (green) and ground on pin 4 (white).

Because the meter carries 2.60 kg, support the pipework so the flange does not take bending loads. Commission by checking that the counter registers pulses at a known flow.

The pre-amplifier output is short-circuit protected at 0.3 W per channel and the total power requirement is at most 0.9 W, so a normal 24 V instrument supply is sufficient. Resolution can be doubled by letting the evaluation use both state changes of every period, a setting made in the counter rather than in the meter.

Care and checks for TM 8 H F 040 S

Inspect the carbide bearings if the pulse count drifts or the rotor feels rough. Calibration against a reference is suggested for accuracy-critical duties, and a strainer upstream protects the rotor from particles.

Ordering and related products

Related: TM 16 T F 040 A, TM 34 H F 040 L and TM 68 H F 040 S flanged meters, and TM 4 T R 320 S in pipe design. Ask for TM 8 H F 040 S by its full code so that bearing, flange and electronics are correct.

Documents and quotation

The datasheet accompanies this page. Send TM 8 H F 040 S with quantity as an RFQ to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.

Selection Notes for the KRACHT TM 8 H F 040 S

When comparing the KRACHT TM 8 H F 040 S with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the KRACHT turbine & positive displacement flowmeters range and confirm the correct order code before you commit.

Other Models in the Kracht Tm Turbine Range

Seven Star LLC supplies models from the Kracht Tm Turbine range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
KRACHT TM 1.1 H R 320 A Turbine Flow Meter 4-20 mATurbine & Positive Displacement FlowmetersView details
KRACHT TM 4 T R 320 S Turbine Flow Meter PTFE BearingTurbine & Positive Displacement FlowmetersView details
KRACHT TM 8 H F 040 S Flanged Turbine Flow Meter DN20Turbine & Positive Displacement FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet KRACHT TM 8 H F 040 S Flanged Turbine Flow Meter DN20 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.

Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.

KRACHT company profile

Founded 1911, registered as Hillebrand & Kracht OHG
Headquarters Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971
Ownership Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company
Size About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco
Subsidiaries USA, China and Hungary (KRACHT Hidraulik Kft.)
Product families External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders

Milestones

  • 1911: Hillebrand & Kracht OHG is entered in the trade register.
  • 1971: The company moves into its present premises in Werdohl.
  • 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
  • 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.

KRACHT pumps, flow meters and valves listed

The listing follows four product groups, pumps, fluid measurement, valves and drives:

  • Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
  • Fluid measurement technology: gear type flow meters such as the VCA in aluminum
  • Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
  • Drive technology: KM hydraulic gear motors

Where KRACHT equipment is used

KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.

KRACHT products we list

Family Examples
Pumps BT / BTH Low-Speed Gear Pump, DT DuroTec Gear Pump for Abrasive Fluids, KD1 Gear Metering Pump, KF 0 Stainless Steel Process Gear Pump, KF Series Modular Gear Pump, KF-F Fuel Gear Pump Series, KF80RF2-D15 Gear Pump, KM Series Hydraulic Gear Motor and 2 more
Flowmeters Fluid Measurement Technology Series, SVC Screw Type Flow Meter, TM Turbine Flow Meter, VC 0.01 Micro Gear Type Flow Meter, VC Gear Type Flow Meter, VCA Aluminum Gear Flow Meter, VCM Gear Flow Meter
Safety Relief Valves DBD Directly Controlled Poppet Valve, DV B Hydraulically Pilot Controlled Valve, HV/HVF Pilot Operated Slide Valve, SPV 10 L1G 1 A 12 Pressure Relief Valve, SPV/SPVF Directly Controlled Slide Valve, Valve Technology Series
Hydraulic Valves & Components CNL Hydraulic Cylinder, DV S Pressure Stage Control Valve
Gear Units & Reducers Drive Technology Series

Ordering KRACHT parts: what we need

KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.

Frequently requested KRACHT models: KRACHT Pump Technology Series.

Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.

FAQ

Questions about the KRACHT TM 8 H F 040 S Flanged Turbine Flow Meter

Answers from our engineering team on installation, compatibility and integration.

01What flange does KRACHT TM 8 H F 040 S have?
It has a DN20 flange connection with an 18 mm nominal bore, a length of 141 mm and a weight of 2.60 kg.
02What is the flow range of TM 8 H F 040 S?
With carbide bearings the range is 26.6 to 133.33 l/min at a typical accuracy of plus/minus 0.5 percent.
03What does 040 mean in TM 8 H F 040 S?
It is the pressure stage for operating pressures up to 40 bar, used only together with a flange connection.
04What electrical output does TM 8 H F 040 S provide?
A square-wave signal, PNP, NPN or push-pull, from a 10 to 30 V DC supply with up to 0.3 W per channel and IP 65 protection.
05Is TM 8 H F 040 S suitable for bidirectional flow?
No, it is unidirectional and the flow direction is marked on the housing; mount it horizontally within plus/minus 5 degrees.