- Automation & ControlView all 2,957 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: KRACHT
KRACHT TM 68 H F 040 S DN50 Turbine Flow Meter
Description
The largest KRACHT turbine meter: TM 68 H F 040 S
KRACHT TM 68 H F 040 S is the top of the TM size range. Nominal size 68 corresponds to 68 m3/h, which is 1133.33 l/min, on a DN50 flange. It has carbide bearings, the 040 pressure stage and the standard electronics that deliver a square-wave signal for any counter or PLC input.
No other TM size comes near it: it weighs 8.30 kg, is 198 mm long and measures from 227.0 l/min. This makes it the natural choice for main headers and transfer lines, while the smaller sizes serve branch lines and dosing.
Data table for TM 68 H F 040 S
| Parameter | Value |
|---|---|
| Type code | TM 68 H F 040 S |
| Nominal size | 68 (68 m3/h) |
| Flange | DN50, bore 50 mm |
| Measuring range, carbide | 227.0 to 1133.33 l/min |
| PTFE alternative at size 68 | 227.0 to 1133.33 l/min |
| Typical accuracy | plus/minus 0.5 percent |
| Length | 198.0 mm |
| Dimension C | 95.0 mm |
| Weight | 8.30 kg |
| Pressure stage | 040, up to 40 bar |
| Media temperature | -40 to 120 C |
| Ambient temperature | -40 to 80 C |
| Supply | 10 to 30 V DC |
| Output | PNP / NPN / push-pull square wave |
| Maximum power requirement | 0.9 W |
| Housing, rotor, flanges | Stainless steel 1.4541 |
| Protection | IP 65 |
Differences between TM 68 H F 040 S and smaller TM turbines
At size 68 the PTFE and carbide ranges match at 227.0 to 1133.33 l/min, so the bearing letter makes no difference to the range here, in contrast with sizes 8, 16 and 34 where PTFE lowers the minimum. The weight rises steeply: 8.30 kg compared with 3.70 kg for the DN25 size 16 and 6.20 kg for the DN40 size 34.
Compared with the IO-Link TM 34 H F 040 L this meter is purely a pulse device, but its media limit of 120 C is much higher than the 80 C of the IO-Link electronics. It also shares the plus/minus 0.5 percent accuracy of all sizes from 2.2 upwards.
Where TM 68 H F 040 S belongs in a plant
A DN50 turbine at over 1000 l/min is suited to fuel oil headers, seawater cooling take-off loops that are treated and clean, filling stations, water treatment backwash and large lube oil circuits. The pulses are accepted by flow computers and batch controllers used in oil and gas terminals and in industrial plants throughout Oman.
The datasheet’s low pressure drop and low noise emission are valuable on big flows, but the medium must still be a thin liquid up to 50 mm2/s.
In power stations and desalination units the meter is also used to confirm the delivery of chemicals and fuel in batches: the controller counts pulses and closes the valve once the programmed volume has passed. Doubling the resolution by using both state changes of every period gives finer batch cut-off at the cost of a higher input frequency, which the counter must be able to process.
Fitting TM 68 H F 040 S
Prepare a flanged spool with DN50 counter flanges and gaskets, install the meter horizontally within plus/minus 5 degrees in the flow direction, and support the 8.30 kg body independently of the pipe stress. Straight lengths for flow conditioning matter more at high flow, so follow the manufacturer’s arrangement.
Electrical hookup uses the four-pole M12x1: supply on pin 1, channel 1 on pin 2, ground on pin 4. Pulse amplitude is at least 80 percent of the supply voltage and the duty factor lies at 50 percent plus/minus 15.
After wiring, fill the pipe slowly and vent it; a rotor of this size can be damaged by air hammer or by a sudden start of a large pump. Verify that the first batch reading agrees with tank-level change or a reference meter before releasing the line to production.
Compatibility and selection notes for TM 68 H F 040 S
Make sure the medium has density 500 to 1500 kg/m3, viscosity 1.0 to 50 mm2/s, solids below 50 g per cubic metre and particles of hardness up to 100 HB. Choose a filter that protects the rotor. If the control system needs 4 to 20 mA, the same hydraulics are available with the A code; for IO-Link, ask for L.
Large turbines are sensitive to the inlet profile. A disturbed flow from a partly closed valve or a pipe elbow immediately upstream shifts the effective calibration, so keep the manufacturer’s flow-calming sections and avoid throttling valves just before the meter. A meter installed in a line that is sometimes empty should be fitted where the pipe stays full, since an empty run lets the rotor spin without liquid damping.
Service and calibration of TM 68 H F 040 S
The datasheet advises calibration for high-precision applications. Inspect the carbide bearings at planned shutdowns and compare the reading with a reference on the same line.
A rising threshold for the lowest detectable flow, a visible loss of accuracy at the low end of the 227.0 l/min range, or an audible rub are the usual signs that the bearings or rotor need replacement. Store the meter dry and capped if it is removed for a long period.
Ordering and FAQ summary
Quote the complete code and ask for related sizes if the plant has several lines, for example TM 34 H F 040 L, TM 16 T F 040 A and TM 8 H F 040 S.
Documents and quotation
The datasheet is attached to this page. Send an RFQ for TM 68 H F 040 S with the quantity to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.
Installation and Commissioning Planning
Planning ahead shortens downtime when a KRACHT TM 68 H F 040 S goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the KRACHT equipment can be planned around it.
Typical Questions From Maintenance Teams
Maintenance engineers replacing a KRACHT TM 68 H F 040 S usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed turbine & positive displacement flowmeters, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.
Other Models in the Kracht Tm Turbine Range
Seven Star LLC supplies models from the Kracht Tm Turbine range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT TM 1.1 H R 320 A Turbine Flow Meter 4-20 mA | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 4 T R 320 S Turbine Flow Meter PTFE Bearing | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 8 H F 040 S Flanged Turbine Flow Meter DN20 | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 16 T F 040 A Turbine Flow Meter DN25 4-20 mA | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 34 H F 040 L IO-Link Turbine Flow Meter DN40 | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT TM 68 H F 040 S DN50 Turbine Flow Meter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet KRACHT TM 68 H F 040 S DN50 Turbine Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT TM 68 H F 040 S DN50 Turbine Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What is the measuring range of KRACHT TM 68 H F 040 S?
The datasheet gives 227.0 to 1133.33 l/min for nominal size 68 at a typical accuracy of plus/minus 0.5 percent.
02How heavy is TM 68 H F 040 S?
The DN50 flanged body weighs 8.30 kg and is 198.0 mm long, so support it properly in the pipe run.
03What signal does TM 68 H F 040 S output?
A square-wave signal with PNP, NPN or push-pull output from the integrated pre-amplifier on a 10 to 30 V DC supply.
04Which temperature range applies to TM 68 H F 040 S?
Media from -40 to 120 C and ambient from -40 to 80 C for the standard electronic version.
05What pressure can TM 68 H F 040 S handle?
The 040 pressure stage means operating pressure up to 40 bar.


















Reviews
There are no reviews yet.