Brand:

KRACHT TM 16 T F 040 A Turbine Flow Meter DN25 4-20 mA

Description

Why buyers look for KRACHT TM 16 T F 040 A

Many control systems in refineries, water plants and factories accept only current loops, and a pulse turbine then needs a converter in the cabinet. KRACHT TM 16 T F 040 A removes that step: it is a DN25 flanged turbine with PTFE bearings and integrated analogue electronics that deliver 4 to 20 mA straight from the meter body.

Reading the code: TM turbine meter, size 16 (up to 16 m3/h), T for PTFE bearings, F for flange connection, 040 for the 40 bar stage and A for the analogue electronics. The housing, flanges and rotor are stainless steel 1.4541 (X6CrNiTi18-10).

Measuring data and ratings of TM 16 T F 040 A

Parameter Value
Type code TM 16 T F 040 A
Nominal size 16 (16 m3/h maximum)
Flange DN25, nominal bore 25 mm
Measuring range, PTFE 26.7 to 266.67 l/min
Measuring range, carbide alternative 53.4 to 266.67 l/min
Typical accuracy plus/minus 0.5 percent
Length 153.5 mm
Dimension C 83.0 mm
Weight 3.70 kg
Pressure stage 040, up to 40 bar
Analogue output 0 to 24 mA, measuring range 4 to 20 mA, 16 bit
Supply 10 to 30 V DC, reverse polarity protection up to 30 V
Load on analogue output maximum 793 ohm at 24 V DC
Digital output up to 100 mA, short-circuit protected
Media temperature, analogue -40 to 80 C
Ambient temperature, analogue -40 to 60 C above 15 V supply, -40 to 80 C below 15 V
Power requirement 1.4 W without outputs loaded
Protection IP 65

Analogue electronics explained for TM 16 T F 040 A

The analogue module was developed for the current inputs found on control systems and measuring devices. The 4 to 20 mA span is not fixed to the full flow of the meter: it can be individualised so that, for example, a window of 8 to 40 l/min fills the whole loop, and the electronics include cable break detection.

A built-in LED reports the flow proportionally. It shines continuously green when there is no measurable flow, flashes green and red while the flow lies inside the measurable range, and turns continuously red when the maximum flow is exceeded. The five-pole M12x1 plug carries supply (brown, pin 1), analogue output (white, pin 2), ground (blue, pin 3), digital output (black, pin 4) and digital input (grey, pin 5).

Resolution is 16 bit, which is helpful when the loop is scaled to a narrow flow window. The digital output is high above the supply voltage minus 3 V and low below 3 V, and its 100 mA capability is short-circuit protected, so it can drive a small relay or alarm input directly while the analogue loop carries the flow value.

The unit is reverse-polarity protected up to 30 V DC. Power draw is a modest 1.4 W before the outputs are loaded, which is relevant for solar or battery-backed remote skids where every watt counts.

How TM 16 T F 040 A differs from similar KRACHT TM models

The size 16 PTFE bearing extends the lower limit to 26.7 l/min, half of the 53.4 l/min that applies with carbide, which makes this version better for plants with large turndown. Compared with the TM 8 H F 040 S (DN20, 141 mm, 2.60 kg, 26.6 to 133.33 l/min) it carries twice the flow, adds 12.5 mm of length and 1.10 kg of weight.

Compared with the TM 34 H F 040 L (DN40, 179 mm, 6.20 kg), the size 16 stays on a DN25 flange and uses analogue electronics rather than IO-Link. The analogue version also loses some thermal margin: its media limit is 80 C, not the 120 C of the standard pulse version.

Industrial uses of TM 16 T F 040 A in Oman and the GCC

At 266 l/min the meter fits lube oil circuits of compressors, jacket water loops, fuel transfer to day tanks, process water make-up and filter backwash lines. The current output goes through plain instrument cable to a remote DCS panel, so it is convenient where the control room is far from the skid.

Low pressure drop and a quiet measuring principle suit lines where pulsation from the meter itself would be unwelcome. Stay within 1.0 to 50 mm2/s and do not use it on abrasive slurries.

Installation and start-up of TM 16 T F 040 A

Fit the DN25 flange pair with correct gaskets, keep the housing horizontal within plus/minus 5 degrees and follow the arrow. Provide the flow-calming lengths the manufacturer mentions before and after the meter, and place a strainer upstream because the datasheet limits particle hardness to 100 HB and the PTFE bearing pair is meant for clean liquid.

Check supply polarity, ensure the loop resistor stays under 793 ohm at 24 V and, if the 4 to 20 mA span must be changed from the default, scale it before the plant is handed over.

Maintenance of TM 16 T F 040 A

PTFE bearings wear slowly in clean service. Watch the LED during start-up trips; a persistently red LED means you are above the configured range, while a green LED at known flow indicates a stuck rotor or a wiring fault. Compare the loop reading to a portable reference at planned intervals.

Ordering and summary of FAQs for TM 16 T F 040 A

Ordering requires the complete code and the scaling you want. Alternatives in the family include TM 8 H F 040 S, TM 34 H F 040 L, TM 68 H F 040 S and the pipe-connection TM 1.1 H R 320 A, which has the same analogue electronics.

Documents and quotation

The KRACHT TM datasheet is attached. Send an RFQ for TM 16 T F 040 A with the quantity and the required measuring span to Seven Star LLC, an independent supplier serving Oman and the GCC and not affiliated with the manufacturer.

Documentation and Compliance

Industrial buyers often need more than the hardware. When you order the KRACHT TM 16 T F 040 A, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that KRACHT turbine & positive displacement flowmeters items can be checked against the bill of materials quickly.

Other Models in the Kracht Tm Turbine Range

Seven Star LLC supplies models from the Kracht Tm Turbine range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
KRACHT TM 1.1 H R 320 A Turbine Flow Meter 4-20 mATurbine & Positive Displacement FlowmetersView details
KRACHT TM 4 T R 320 S Turbine Flow Meter PTFE BearingTurbine & Positive Displacement FlowmetersView details
KRACHT TM 8 H F 040 S Flanged Turbine Flow Meter DN20Turbine & Positive Displacement FlowmetersView details
KRACHT TM 16 T F 040 A Turbine Flow Meter DN25 4-20 mATurbine & Positive Displacement FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet KRACHT TM 16 T F 040 A Turbine Flow Meter DN25 4-20 mA Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.

Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.

KRACHT company profile

Founded 1911, registered as Hillebrand & Kracht OHG
Headquarters Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971
Ownership Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company
Size About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco
Subsidiaries USA, China and Hungary (KRACHT Hidraulik Kft.)
Product families External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders

Milestones

  • 1911: Hillebrand & Kracht OHG is entered in the trade register.
  • 1971: The company moves into its present premises in Werdohl.
  • 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
  • 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.

KRACHT pumps, flow meters and valves listed

The listing follows four product groups, pumps, fluid measurement, valves and drives:

  • Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
  • Fluid measurement technology: gear type flow meters such as the VCA in aluminum
  • Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
  • Drive technology: KM hydraulic gear motors

Where KRACHT equipment is used

KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.

KRACHT products we list

Family Examples
Pumps BT / BTH Low-Speed Gear Pump, DT DuroTec Gear Pump for Abrasive Fluids, KD1 Gear Metering Pump, KF 0 Stainless Steel Process Gear Pump, KF Series Modular Gear Pump, KF-F Fuel Gear Pump Series, KF80RF2-D15 Gear Pump, KM Series Hydraulic Gear Motor and 2 more
Flowmeters Fluid Measurement Technology Series, SVC Screw Type Flow Meter, TM Turbine Flow Meter, VC 0.01 Micro Gear Type Flow Meter, VC Gear Type Flow Meter, VCA Aluminum Gear Flow Meter, VCM Gear Flow Meter
Safety Relief Valves DBD Directly Controlled Poppet Valve, DV B Hydraulically Pilot Controlled Valve, HV/HVF Pilot Operated Slide Valve, SPV 10 L1G 1 A 12 Pressure Relief Valve, SPV/SPVF Directly Controlled Slide Valve, Valve Technology Series
Hydraulic Valves & Components CNL Hydraulic Cylinder, DV S Pressure Stage Control Valve
Gear Units & Reducers Drive Technology Series

Ordering KRACHT parts: what we need

KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.

Frequently requested KRACHT models: KRACHT Pump Technology Series.

Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.

FAQ

Questions about the KRACHT TM 16 T F 040 A Turbine Flow Meter DN25 4-20

Answers from our engineering team on installation, compatibility and integration.

01What output does KRACHT TM 16 T F 040 A have?
It provides an analogue 0 to 24 mA output with a 4 to 20 mA measuring range at 16 bit resolution, plus a digital output up to 100 mA.
02What is the measuring range of TM 16 T F 040 A?
With PTFE bearings the datasheet gives 26.7 to 266.67 l/min for nominal size 16 at plus/minus 0.5 percent typical accuracy.
03What does the LED on TM 16 T F 040 A show?
Continuous green means no measurable flow, flashing green and red means flow in the measuring range, and continuous red means the maximum flow is exceeded.
04What flange and pressure does TM 16 T F 040 A use?
A DN25 flange in the 040 stage, rated for operating pressures up to 40 bar, with a length of 153.5 mm and a weight of 3.70 kg.
05Up to what temperature can TM 16 T F 040 A be used?
The analogue version is rated for media from -40 to 80 C, and ambient from -40 to 60 C above 15 V supply or -40 to 80 C below 15 V.