Fluke 323 True-RMS Clamp Meter, 400 A

Description

323 400 A true-RMS clamp meter explained

The Fluke 323 True-RMS Clamp Meter (323) is an entry-level true-RMS clamp meter that measures up to 400 A AC and 600 V, with resistance and continuity. Its slim jaw and large display are intended for tight cable compartments. Seven Star LLC supplies 323 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The 323 is the base model of the 320 series. The table decodes its key facts.

Element Value Meaning
323 Model Basic model of the 320 series
400 A Current range AC only
True-RMS AC response Non-linear loads read correctly
CAT III 600 V / CAT IV 300 V Safety rating Dual rating

323 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 323
AC current 400.0 A, 2% ± 5 digits (45 Hz to 65 Hz)
DC current Not measured
AC voltage 600.0 V, 1.5% ± 5 digits
DC voltage 600.0 V, 1.0% ± 5 digits
Resistance 400.0 Ω / 4000 Ω, 1.0% ± 5 digits
Continuity ≤ 70 Ω
Maximum conductor 30 mm (600 MCM)
Size / weight 207 x 75 x 34 mm / 265 g
Category rating CAT III 600 V, CAT IV 300 V
Warranty Two years

Data are from the manufacturer product page for the Fluke 323.

How the Fluke 323 True-RMS Clamp Meter works

The 323 senses AC current through the jaw by induction, so the circuit is not broken. True-RMS processing handles distorted loads such as electronic drives within the stated frequency band. Test leads are used for voltage, resistance and continuity.

The hold function freezes the display, which helps when the jaw sits in a position where the screen cannot be read. The slim body is meant to reach into narrow wiring compartments.

Key features

  • Slim ergonomic design
  • Large easy-to-read display
  • Hold function
  • Soft carrying case and two-year warranty
  • Voltage, resistance and continuity

Where 323 fits and related Fluke models

The 323 has no DC current, frequency, temperature or min/max. The 325 adds all of these, and the 355 targets currents to 2000 A. For wireless use and higher accuracy, the 374 FC and 375 FC are the step up.

If your work is only load verification on AC feeders, the 323 is sufficient.

Selection checklist for 323

Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.

  • AC-only current: pick the 325 for DC.
  • Maximum conductor diameter 30 mm.
  • Rated CAT III 600 V / CAT IV 300 V.
  • Case and leads are included.

Safe use, care and maintenance of 323

  • Close the jaw fully and check that the faces are clean. Dirt or rust on the jaw faces causes reading errors, and a jaw that does not close completely should be taken out of service.
  • Clamp only one conductor at a time. Two conductors of a single-phase pair or a three-phase set cancel each other and the 323 will show a value close to zero.
  • Verify the clamp on a known live circuit before and after any test that decides whether equipment is safe to touch.
  • Replace batteries when the low-battery indicator appears and remove them for long storage. Inspect the test leads for damage before each use of the voltage and resistance functions.
  • Keep the jaw and display free of dust. In dusty Gulf sites, use the supplied case and wipe the instrument after switchgear room work.
  • Respect the maximum conductor size and never clamp bare busbars unless the rating and your site procedure allow it. Treat the clamp as a measuring tool, not a switch or an isolator.
  • Allow the instrument to reach ambient temperature after moving it from an air-conditioned vehicle into a hot plant area, so that condensation does not form inside the housing and the display settles.
  • Schedule periodic calibration through your quality system, and keep the certificate with the instrument record so that readings used for reports remain traceable.

Typical applications of 323 in Oman and the GCC

Clamp meters are used for load checks on motors, feeders, chillers and pump drives. In Oman, maintenance teams at oil and gas plants, power and water utilities, desalination units and petrochemical sites use them for current surveys without opening circuits. A clamp reading showing a motor drawing more than its nameplate current points to a mechanical overload, a supply imbalance or a failing winding, while a reading near zero on a running pump suggests a lost phase or dry running. Because the circuit stays intact, these checks can be done on live equipment under a permit, which keeps downtime low during the hot summer months when cooling and pumping loads peak.

The 323 serves facility maintenance and electrical contractors verifying that loads draw current. In Oman it fits commercial buildings, camps and light industrial plants where a basic AC clamp is enough for pump, fan and compressor checks.

323 compared with nearby models

Model Current range DC current Temperature
323 400 A AC No No
325 400 A AC/DC Yes Yes
355 2000 A Yes No

See each model page for additional functions.

Information to send with an RFQ for 323

To prepare an accurate quotation, please send:

  • Exact model 323 and the quantity required.
  • Maximum conductor size and expected current, so the jaw or flexible probe option can be confirmed.
  • Whether wireless or smartphone use is needed on site.
  • Any extra accessories such as a hanging strap, leads or a case.
  • Calibration traceability paperwork if required on delivery.
  • Delivery point in Oman or elsewhere in the GCC and the required date.

Storage, handling and spares for the Fluke 323

Store the Fluke 323 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.

  • Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
  • Use only leads and accessories rated for the same or a higher measurement category than the work you do.
  • Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
  • Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.

If your team uses several units of the Fluke 323, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.

Documents and quotation

Send the part number 323 and we will confirm which manufacturer documents are available for this model.

For a quotation, send the part number 323, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.

Other Models in the Fluke 320 Series Clamp Range

Seven Star LLC supplies models from the Fluke 320 Series Clamp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Fluke 323 True-RMS Clamp Meter, 400 AElectrical Testers & MultimetersYou are viewing this model
Fluke 325 True-RMS Clamp Meter with TemperatureElectrical Testers & MultimetersView details
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 323 True-RMS Clamp Meter, 400 A

Answers from our engineering team on installation, compatibility and integration.

01What current can the Fluke 323 measure?
It measures up to 400.0 A AC through the jaw, with 2% plus 5 digits accuracy from 45 Hz to 65 Hz and 2.5% from 65 Hz to 400 Hz.
02Does the 323 measure DC current?
No. The 323 is an AC-current clamp; for DC current choose the 325 or a higher model in the range.
03Is it true-RMS?
Yes, it provides True-RMS AC current and voltage readings, so loads with distorted waveforms are measured correctly.
04What is the largest conductor it fits?
The jaw takes conductors up to 30 mm (600 MCM); larger cables need a flexible-probe clamp meter.
05What warranty applies?
The manufacturer lists a two-year warranty and includes a soft carrying case and test leads in the box.