- Automation & ControlView all 3,166 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: EUCHNER
EUCHNER TP2-528A024M Guard Locking Switch, Power Lock
Description
Overview
People who work inside a guarded cell want the door to open if the power fails, not stay shut. The EUCHNER TP2-528A024M is the TP series answer: a guard locking switch which holds the door only while its 24 V solenoid is powered. Remove power and a spring lets go. It has a light reinforced thermoplastic housing, lock monitoring contacts and an M20 x 1.5 cable entry, and no contacts for door position. Seven Star LLC is an independent supplier serving Oman and the GCC.
Locking by power in the EUCHNER TP2-528A024M
The product page calls this the open-circuit current principle, also known as electrical guard locking. When the solenoid is energised the bolt is held in the actuator, and when the supply is interrupted the spring pulls the bolt back so the door can be opened. For this reason the TP2 belongs on guards where the hazard stops immediately, for example a pneumatic press with no coasting, a test fixture or a robot cell with a safe stop. For hazards with run-down time the spring locked TP1 or TP3 is the better choice. Always confirm the choice with a documented risk assessment.
Data for EUCHNER TP2-528A024M
| Item | Product page value |
|---|---|
| Locking principle | Open-circuit current, power on to lock |
| Lock monitoring | Element 528: 1 positively driven + 1 NO contact |
| Door position contacts | None |
| Solenoid | 24 V AC/DC, minus 15 to plus 10 percent, 8 W |
| Contact categories | AC-15 4 A at 230 V; DC-13 4 A at 24 V |
| Switching voltage minimum | 12 V at 10 mA |
| Locking force | Fmax 1300 N, Fzh 1000 N |
| Forces | Actuating 10 N, extraction 20 N, retention 10 N |
| Housing and contacts | Reinforced thermoplastic; silver alloy, gold flashed |
| Cable entry | 3 x M20 x 1.5 |
| IP / ambient | IP67; minus 20 to plus 55 degrees C |
| Actuation frequency | 1200 per hour at most |
| B10d guard lock monitoring | 3 million operations, 20 years |
How EUCHNER TP2-528A024M differs from other TP variants
The TP1-538A024M also lacks door contacts but uses spring locking and two positively driven contacts. The TP3-2131A024M adds a door contact and is spring locked. This TP2 is the one that locks by power and releases in a power cut, and its lock monitoring element 528 offers a positively driven contact together with a NO contact for the controller. The code TP2-2121A024M and the connector versions TP2-528A024SR6 and TP2-4131A024M are other members of the same sub-family, each with different contact blocks.
Applications in Oman and the GCC
The TP2 is selected for doors where operators can be inside the area: test benches, hand-fed presses, labelling machines and assembly cells of light industry. Integrators often pair it with a coded sensor on the door to report position. Since the housing is plastic and sealed to IP67, it is also a candidate for humid coastal sites and cleaned areas where metal bodies would corrode.
Mounting and actuator choice
Choose a stainless steel actuator from the NP, GP and TP range. Increased-overtravel types reach 7 mm in the horizontal direction, while the standard rubber-bush actuator gives 2 mm horizontally and 1.5 mm vertically. Mount the head so the bolt moves smoothly and without side loads, rotate the approach direction in 90 degree steps as needed and secure the screws. Wire according to the 528 diagram, using a fuse not larger than 4 A gG, and test the auxiliary release.
Verification and upkeep
Cut the power and confirm that the guard can be opened, then reapply power and check that it locks and that the monitoring contact reports it. Inspect actuator wear and fixings regularly. The operating instructions require that the auxiliary release be sealed against abuse, and that the device not be repaired. Replace after the stated one million operations.
Specifying the EUCHNER TP2-528A024M
Quote the exact code EUCHNER TP2-528A024M, state the actuator and voltage, and confirm that locking on power matches the risk assessment of the machine.
Power failure behaviour and exits for the EUCHNER TP2-528A024M
The most important consequence of locking by power is what happens during a blackout: the spring withdraws the bolt, and the door can be opened at once. If the machine can still be moving, the controller must stop it before power is lost, or the design must provide another way to keep people away, such as a brake that applies when power fails. In a walk-in cell the same behaviour is a benefit, because an operator cannot be shut in by a failed supply. Many designers combine the TP2 with an uninterruptible power supply on the safety circuit so that a brief dip does not unlock the door and stop production, while a long failure still frees the door in a controlled way.
When several guard locks share a supply, think about inrush: each solenoid draws 8 W, and a bank of ten needs 80 W of reserve. Fuse each branch separately where possible, and keep the supply tolerance within minus 15 to plus 10 percent. Where several guards share a supply, number each guard on the drawing and the label. Commission the unit with the full machine cycle and record the result in the safety validation report. Mark the guard with a label explaining that it unlocks without power so that service staff know what to expect. Train operators as well: a door that opens during a stoppage is normal for this version, and nobody should treat it as a fault or try to override it.
Related items you may also need: EUCHNER MSC-CB-AC-FI8FO2 Modular Safety Controller Base Unit | EUCHNER CTM-LBI-BP-U-AZ-SA BiState Guard Locking Switch | EUCHNER STP-TW-3A-2131AC024M Twin Guard Locking Switch | All EUCHNER products.
Documents and quotation
The TP operating instructions are attached to this page and explain mounting, wiring and safety characteristics. Please send your RFQ with EUCHNER TP2-528A024M, the quantity and your delivery location in Oman or the GCC.
Other Models in the Tp Range
Seven Star LLC supplies models from the Tp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER TP1-538A024M Spring-Locked Guard Locking Switch | Safety Switches & Guard Locking | View details |
| EUCHNER TP2-528A024M Guard Locking Switch, Power Lock | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER TP2-528A024M Guard Locking Switch, Power Lock Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER TP2-528A024M Guard Locking Switch, Power
Answers from our engineering team on installation, compatibility and integration.
01Does the EUCHNER TP2-528A024M lock with power or by spring?
It locks while power is applied to the solenoid, using the open-circuit current principle, and releases by spring force without power.
02What contacts does the TP2-528A024M have?
Its 528 element provides one positively driven contact and one NO contact for guard lock monitoring; there are no door position contacts.
03What is the TP2-528A024M locking force?
The product page gives a maximum locking force of 1300 N and a holding force of 1000 N.
04What supply does the TP2-528A024M need?
The solenoid runs on 24 V AC or DC with minus 15 to plus 10 percent tolerance and consumes 8 W.
05How is the TP2-528A024M different from the TP1-538A024M?
The TP2 locks by applying power with a 528 element, whereas the TP1 is spring locked and its 538 element has two positively driven contacts.


















Reviews
There are no reviews yet.