EUCHNER NX1-2131A-M Metal Safety Switch, 3 Pos.+1 NO
Description
Overview
The EUCHNER NX1-2131A-M is a compact metal safety switch from the NX range, designed for guards that open in more than one direction. Its head can approach horizontally or vertically and can be turned in 90 degree steps, so one housing covers sliding, lifting and hinged doors. Inside is a 2131 slow-action contact block with three positively driven contacts and one normally open contact, and the cable entries number three, which helps when conductors enter from different sides. Seven Star LLC is an independent supplier serving Oman and the GCC.
Decoding NX1-2131A-M
NX is the series with the die-cast housing that has been cathodically dipped for corrosion protection. The 1 denotes the cable-gland version, 2131 is the contact set, A refers to the head variant and M to the M20 x 1.5 thread of the three cable entries. The article number is 092624. No actuator is supplied, so the choice is made from the NX and TX actuator range, such as ACTUATOR-X-GQ or the bent and hinged types.
Technical specification of EUCHNER NX1-2131A-M
| Parameter | Data |
|---|---|
| Contacts | 3 positively driven plus 1 NO, slow-action |
| Approach direction | Horizontal and vertical, 90 degree steps |
| Utilization category | AC-15 4 A at 230 V; DC-13 4 A at 24 V |
| Thermal current / fuse | 4 A / up to 4 A gG |
| Voltage ratings | 250 V insulation, 2.5 kV impulse |
| Minimum switching | 12 V, 1 mA at 24 V |
| Connection | 3 x M20 x 1.5, 0.34 to 1.5 square mm |
| Actuating / extraction / retention | 40 N / 50 N / 10 N |
| Insertion depth | 32 mm |
| Actuation frequency | up to 6700 per hour |
| Mechanical life | 2 million cycles |
| Protection / temperature | IP67 / minus 20 to plus 80 degrees C ambient |
| Materials | Cathodically dipped die-cast alloy; silver alloy contacts, gold flashed |
| B10D / mission | 4.5 million cycles / 20 years |
Where the EUCHNER NX1-2131A-M sits among NX1 types
Only a few NX1 codes exist, which makes the differences easy to state. The NX1-2121A-M has four positively driven contacts and no normally open contact. The NX1-3131A-M gives two positively driven and two normally open contacts. The EUCHNER NX1-2131A-M has three positively driven contacts and one normally open contact, and a lamp version, the NX1-2131AL024-M, adds a 24 V indicator. Against the NZ.VZ switches, the NX has a shorter insertion depth of 32 mm, a lighter actuating force of 40 N and a much higher allowed switching frequency of 6700 per hour compared with 1200 per hour.
Application notes for Gulf industry
High switching frequency and a small installation footprint make the switch attractive on automated machinery. Typical examples are robotic palletising cells, bottling and canning lines, packing machines, machining centres and conveyor transfer stations. The cathodically dipped finish resists the humid, salty air found in coastal Omani sites. Where the same machine uses several doors, fitting the same NX type everywhere keeps spares simple.
Actuators and overtravel
With ACTUATOR-X-GQ the usable overtravel is 1 mm, and with ACTUATOR-X-GNQ it reaches 8 mm. The bent versions X-WQ and X-WNQ suit doors where the actuator must approach at an angle, while the radius actuators X-LR-N and X-OU-N follow hinged doors on the left or right and on the top or bottom. All are made of stainless steel and come with two safety screws.
Mounting and wiring practice
Select the approach direction first, then fix the body with the fixing screws provided. The three entries let you separate the safety conductors from a signal cable, and unused entries should be closed with certified plugs to keep the IP67 rating. Use conductors between 0.34 and 1.5 square mm, protect the circuit with a fuse of at most 4 A gG and test the monitoring function with the door at both ends of its tolerance range.
Care of the switch
Because the actuating frequency may be high, inspect the actuator and the entry funnel more often than on rarely used guards. Replace the actuator when its tip is worn, look for oil or coolant creeping into the head and make sure the actuator is still fixed with the tamper-resistant safety screws. A permanent contact test during each maintenance round is useful.
Reliability data for safety calculations
The manufacturer lists a B10D value of 4.5 million cycles for monitoring the guard position and a mission time of 20 years for the EUCHNER NX1-2131A-M, valid for DC-13 loads of 100 mA at 24 V. These figures are used together with the architecture of the circuit to derive the performance level under EN ISO 13849-1 or the safety integrity under EN IEC 62061. Three positively driven contacts give designers freedom: two can be taken to the two channels of a relay while the third serves a second function, for example a redundant input of a safety PLC. The remaining normally open contact is a convenient door-closed signal that is not part of the safety chain.
When the switching frequency is high, count the real number of cycles per year and compare it with the B10D value, since the useful life of the function is limited by whichever comes first, the mission time or the cycle count.
Choosing between metal and plastic housings
If the environment is mechanically rough or the machine is cleaned with strong jets, the metal housing of the NX is preferred. In clean, lightweight installations a plastic housing from the SGP or NP families may be adequate and lighter. The NX also keeps a small cross-section, which helps on narrow door frames, and its head orientation can be adjusted without special tools.
Ordering information for EUCHNER NX1-2131A-M
Quote the full code and indicate whether a straight, bent or hinged actuator is required. Cable glands for M20 x 1.5 thread can be added to the same order. When the switch replaces an older NX, let us know the old code so that the contact block can be compared.
Related items you may also need: EUCHNER TX1B-A024M Guard Locking Safety Switch | EUCHNER RPS-M-2131SR175M Emergency Stop Rope Pull Switch | EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V | All EUCHNER products.
Documents and quotation
The manufacturer operating instructions for the NX safety switch are attached and show the dimensions, contact diagram and technical data. Send your RFQ with EUCHNER NX1-2131A-M, the required quantity and the delivery destination in Oman or the GCC.
Datasheets & Documents
- Datasheet EUCHNER NX1-2131A-M Metal Safety Switch, 3 Pos.+1 NO Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER NX1-2131A-M Metal Safety Switch, 3 Pos.+1 NO
Answers from our engineering team on installation, compatibility and integration.
01How many cable entries does the EUCHNER NX1-2131A-M have?
It has three M20 x 1.5 cable entries, so conductors can enter from different sides of the metal housing.
02What contact set does the EUCHNER NX1-2131A-M carry?
The 2131 slow-action block provides three positively driven contacts and one normally open contact.
03How is the NX1-2131A-M different from the NX1-3131A-M?
The 3131 has two positively driven and two normally open contacts, whereas the 2131 has three positively driven and one normally open contact.
04What overtravel can be used with the NX1-2131A-M?
With ACTUATOR-X-GQ the overtravel is 1 mm, and with ACTUATOR-X-GNQ it is 8 mm. The actuator is ordered separately.
05What switching frequency does the NX1-2131A-M allow?
The manufacturer states up to 6700 actuations per hour, with a mechanical life of 2 million cycles and IP67 protection.


















Reviews