- Automation & ControlView all 3,144 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: EUCHNER
EUCHNER TZ1LE024MVAB Guard Locking Safety Switch, 8 Contacts
Description
Overview
Some guards need more than the minimum pair of contacts, for instance when separate signals go to a safety relay, a PLC and a visual indicator. The EUCHNER TZ1LE024MVAB answers that need with the TZ guard locking housing and a richer contact layout: three positively driven contacts plus one normally open contact for door monitoring, and two positively driven contacts plus two normally open contacts for lock monitoring. It has a left-hand head, a 24 V solenoid, an M20 x 1.5 cable entry and an auxiliary release. Seven Star LLC is an independent supplier serving Oman and the GCC.
Contact layout of the EUCHNER TZ1LE024MVAB
The product page names the switching elements SK 2131 for the door and UK 3131 for the lock. The door side gives three positively driven contacts, which are opened by the movement of the actuator even if a contact welds, and one NO contact for signalling. The lock side has two positively driven plus two NO contacts. In practice, an installer can send one positively driven door contact and one lock contact to each channel of a two-channel safety relay, while the spare contacts go to a PLC for diagnostics or to a second relay for a muting or reset function. All contacts are slow-action types with silver alloy, gold flashed surfaces.
Technical values for EUCHNER TZ1LE024MVAB
| Parameter | Value |
|---|---|
| Door monitoring | SK 2131: 3 positively driven + 1 NO |
| Lock monitoring | UK 3131: 2 positively driven + 2 NO |
| Locking principle | Closed-circuit current (power to unlock), spring locked |
| Solenoid | 24 V AC/DC, minus 15 to plus 10 percent, 10 W |
| Contact rating | AC-15 4 A 230 V; DC-13 4 A 24 V; thermal current 4 A |
| Fuse | 4 A gG maximum (2 A gG above 70 degrees C) |
| Locking force | Fmax 2000 N, Fzh 1500 N |
| Cable entry | M20 x 1.5, cross section 0.34 to 1.5 mm2 |
| Degree of protection | IP67 |
| Ambient temperature | minus 25 to plus 80 degrees C |
| Approach speed | Up to 20 m/min |
| Mechanical life | 1 million operations |
How EUCHNER TZ1LE024MVAB differs from other TZ variants
The plain TZ1LE024M has the compact 528 contact blocks, offering only one positively driven and one NO contact on each function. The EUCHNER TZ1LE024MVAB replaces them with the 2131 and 3131 blocks, which means four door contacts and four lock contacts instead of two and two. The mounting dimensions, the 10 W solenoid and the locking force of 2000 N stay the same, so it can replace the simpler switch when a design change adds signals. Variants with RC18, SR6 or SR11 connectors also exist for plug-in replacement, and an ASi version offers bus connection with M12.
Typical applications in Oman and the GCC
Larger production cells are the usual home for this code: robot cells with several doors, injection moulding machines, palletisers and large machine tools in industrial zones of Muscat, Sohar and Salalah. There the safety system is often built around a configurable safety controller that reads several contacts per guard, and the extra contacts of the EUCHNER TZ1LE024MVAB save a separate monitoring switch. The IP67 housing and anodised die-cast construction survive dust, coolant mist and rough handling.
Wiring and set-up
Terminate the cable at the screw terminals in the housing, and draw up the circuit with the wiring diagram labelled SK 2131H and UK 3131H in the product documentation. Use conductor cross sections between 0.34 and 1.5 mm2, protect the circuit with a fuse not above 4 A gG, and respect the minimum switching load of 12 V at 10 mA so that the contacts remain reliable. The switch needs a TZ bolt, which is ordered separately. Align the bolt carefully, mount the unit securely and test both the monitoring contacts and the auxiliary release before putting the machine into service.
Maintenance and verification
Under the safety standards, the function of the interlock should be tested at regular intervals. Open the guard and confirm that the safety circuit drops, then close it, energise the solenoid and check that the bolt can be withdrawn only when intended. Keep the bolt opening clean, and replace the switch after its stated mechanical life. Do not attempt to repair the device. For performance level calculations use the B10d value of 3 million operations for guard position monitoring and the mission time of 20 years from the data sheet.
Compatibility and ordering information
Select this code if your safety controller needs the extra contacts, and select the plain TZ1LE024M if it does not. Confirm head position, voltage and connection style, then quote with the exact code EUCHNER TZ1LE024MVAB and name the bolt you need alongside it.
Safety function and design checks for the EUCHNER TZ1LE024MVAB
A guard locking switch is only one element in a safety function, and the designer must work out the achievable performance level from the data of every part in the chain. For the EUCHNER TZ1LE024MVAB, the data sheet supplies the B10d value of 3 million operations for guard position monitoring and a mission time of 20 years, so the contribution of the switch can be calculated with the usual formulas. Add the evaluation device, the wiring and the output contactors, and consider the diagnostic coverage achieved by the two-channel connection of the positively driven contacts. Also decide whether the guard locking function itself is a safety function: where locking protects people from a hazard, the solenoid control and the lock monitoring must be included in the calculation, and the design should avoid unintended unlocking through a single fault in the control wiring. These checks are described in the operating instructions, which also list the relevant standards.
It is good practice to write the chosen values on the machine documentation so that later modifications do not erode the safety level: number of operations per hour, supply voltage tolerance and the fuse rating. Keep spare actuators in stock as well, since a bent actuator is the most common cause of a guard door that refuses to close.
Related items you may also need: EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch, M12 | EUCHNER CES-IA-BR-U-C07-SA Non-Contact Safety Switch Set | EUCHNER STP-TW-3A-2131AC024M Twin Guard Locking Switch | All EUCHNER products.
Documents and quotation
The TZ operating instructions are attached to this page. They include mounting data, wiring and safety characteristics. Please send your RFQ with EUCHNER TZ1LE024MVAB, the quantity and your delivery location in Oman or the GCC.
Other Models in the Tz Range
Seven Star LLC supplies models from the Tz range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER TZ1LE024M Guard Locking Safety Switch, 24 V | Safety Switches & Guard Locking | View details |
| EUCHNER TZ1RE024M Guard Locking Switch, Head Right | Safety Switches & Guard Locking | View details |
| EUCHNER TZ1LE024MVAB Guard Locking Safety Switch, 8 Contacts | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER TZ1LE024MVAB Guard Locking Safety Switch, 8 Contacts Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER TZ1LE024MVAB Guard Locking Safety Switch, 8
Answers from our engineering team on installation, compatibility and integration.
01What contacts does the EUCHNER TZ1LE024MVAB provide?
Door monitoring SK 2131 has 3 positively driven plus 1 NO contact, and lock monitoring UK 3131 has 2 positively driven plus 2 NO contacts.
02How is the TZ1LE024MVAB different from the TZ1LE024M?
It uses the 2131 and 3131 contact blocks with four contacts per function, whereas the TZ1LE024M has the smaller 528 blocks with two contacts per function.
03What solenoid supply does the TZ1LE024MVAB use?
It uses a 24 V AC or DC solenoid, minus 15 to plus 10 percent, drawing 10 W with a 100 percent duty cycle.
04Is the TZ1LE024MVAB locked without power?
Yes. It follows the closed-circuit current principle, so spring force keeps the bolt locked until the solenoid is energised.
05What protection class is the TZ1LE024MVAB?
It is rated IP67 with an anodised die-cast alloy housing and an ambient range of minus 25 to plus 80 degrees C.


















Reviews