- Automation & ControlView all 3,043 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: EUCHNER
EUCHNER NP1-648AS-M Compact Safety Switch, EN 50047
Description
Overview
The EUCHNER NP1-648AS-M is a small safety switch in the NP series, shaped to fit the old EN 50047 mounting pattern that many existing limit-switch positions still use. That makes it a practical retrofit part where a guard has been monitored by a standard limit switch and a safer, actuator-coded device is needed without drilling new holes. Its housing is reinforced thermoplastic, and the 648 slow-action element offers two positively driven contacts and one normally open contact. Seven Star LLC is an independent supplier serving Oman and the GCC.
Meaning of the code NP1-648AS-M
NP is the compact plastic safety switch family. The 1 shows cable-gland connection, 648 names the contact arrangement, AS marks mounting according to EN 50047 (the neighbouring AB version uses a 40 mm hole spacing), and M indicates a single M20 x 1.5 entry. The article number is 082280, and the actuator must be ordered separately.
Electrical and mechanical data for EUCHNER NP1-648AS-M
| Characteristic | Manufacturer value |
|---|---|
| Contacts | 648: 2 positively driven plus 1 NO, slow-action |
| Mounting | According to EN 50047 |
| Utilization category | DC-13 4 A 24 V; AC-15 4 A 230 V |
| Voltage ratings | 250 V insulation, 2.5 kV impulse |
| Minimum load | 24 V at 10 mA; 30 mA at 24 V |
| Fuse and cross-section | up to 4 A gG; 0.34 to 1.5 square mm |
| Connection | 1 x M20 x 1.5 |
| Actuating force | 5 N; extraction force 15 N; retention 2 N |
| Insertion depth | 28 mm horizontal, 29.5 mm vertical |
| Actuation rate | up to 7000 per hour |
| Mechanical life | 1 million cycles |
| Protection / temperature | IP67 / minus 20 to plus 80 degrees C |
| B10D, mission time | 3 million cycles, 20 years |
How EUCHNER NP1-648AS-M differs from other NP variants
All NP1 versions share the plastic body but vary in mounting and contacts. The NP1-628AS-M carries one positively driven and one normally open contact, the NP1-638AS-M two positively driven contacts, and the EUCHNER NP1-648AS-M adds a normally open contact on top of two positively driven ones. Replace AS with AB and the mounting changes to a 40 mm spacing. The NP2-648AS uses a six-pin SR6 plug connector, and the NP3 versions use an M12 plug. Within the family the minimum load of 24 V at 10 mA is higher than on the SGP and NZ.VZ types, so check the relay input before substituting.
Applications
With an actuating force of only 5 N, the switch is ideal for light covers and flaps, such as maintenance hatches on conveyors, covers of laboratory machines, pump guards, dosing units, printing machines and small assembly stations. In Oman it frequently replaces limit switches on existing machinery, because the EN 50047 mounting pattern lets it use the same holes. The reduced size also suits narrow door posts in panel-built machines.
Actuators
The NP actuators are the P-type range. With ACTUATOR-P-GT the overtravel is 2 mm in the horizontal and 1.5 mm in the vertical approach, and with ACTUATOR-P-GNT the horizontal overtravel grows to 7 mm. Because the retention force is just 2 N, the actuator is held by the door and not by the switch, so mounting must keep the door from rebounding into the slot.
Installation and commissioning
Verify that the existing hole pattern really matches EN 50047, then fix the body and set the head direction. Wire the two positively driven contacts to the safety relay and take the normally open contact to a signalling input. Remember that the minimum load of 24 V and 10 mA is intended for low-energy circuits; a relay input drawing less may need a different type. Test the actuator in both horizontal and vertical movement if the door can be opened in both ways.
Maintenance
The mechanical life of 1 million cycles is half that of the larger EUCHNER switches, so on doors opened many times each day keep a record of the cycle count and plan replacement well before the figure is reached. Check seals, keep the slot clean and look for hairline cracks in the plastic body.
Safety function planning for the EUCHNER NP1-648AS-M
The data for the EUCHNER NP1-648AS-M enter the calculation of the complete safety function together with the relay, the contactors and the wiring. The manufacturer documents a B10D of 3 million cycles for monitoring the guard position and a mission time of 20 years at a load of 100 mA and 24 V in DC-13 use. Because the mechanical life is 1 million cycles, the cycle count on busy doors should be tracked, and the switch replaced before that figure is reached.
Two positively driven contacts connected to separate inputs of a safety relay form a two-channel structure that can detect a single fault, and the normally open contact gives the controller a door-closed message that does not take part in the safety chain. Record the actuator type, the overtravel and the date of installation in the machine file.
Fault finding in service
When a machine stops without reason, first check the actuator alignment and make sure that the door is closing fully. A dented door frame, a loose hinge or a worn stop can leave the actuator only part way into its slot. Look at the terminals for loose conductors, measure the contact resistance with the door closed, and compare the readings of both channels. If moisture is found inside the head, replace the switch and fix the leak path, which is often an open cable entry. Do not bypass the contacts, even temporarily, because a forgotten bridge is a serious hazard.
Keep at least one spare switch and a few actuators in the maintenance store, as these items are small and quickly replaced once the cause of a fault has been found.
Ordering the EUCHNER NP1-648AS-M
Send the full code and say whether the old equipment used a limit switch. Where possible, supply the model of the earlier switch, the hole spacing and the type of actuator needed. Spare actuators and cable glands can be included in the same enquiry.
Related items you may also need: EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch, M12 | EUCHNER ZSB054784 Three-Stage Enabling Switch with +/- Buttons | EUCHNER ESM-BA301 Safety Relay | All EUCHNER products.
Documents and quotation
The manufacturer operating instructions covering the NP safety switch are attached to this page. Please send your RFQ with EUCHNER NP1-648AS-M, the quantity and the delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet EUCHNER NP1-648AS-M Compact Safety Switch, EN 50047 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER NP1-648AS-M Compact Safety Switch, EN 50047
Answers from our engineering team on installation, compatibility and integration.
01What mounting standard does the EUCHNER NP1-648AS-M follow?
The AS suffix means mounting according to EN 50047, so it fits the hole pattern of many standard limit switches. The AB version uses 40 mm spacing.
02What contacts does the EUCHNER NP1-648AS-M offer?
The 648 slow-action element provides two positively driven contacts and one normally open contact.
03What actuating force does the NP1-648AS-M need?
The actuating force is only 5 N, the extraction force is 15 N and the retention force is 2 N, which suits light covers.
04What overtravel is available for the NP1-648AS-M?
With ACTUATOR-P-GT it is 2 mm horizontal and 1.5 mm vertical, and with ACTUATOR-P-GNT the horizontal overtravel is 7 mm.
05What is the minimum switching load of the NP1-648AS-M?
The manufacturer lists a minimum of 24 V at 10 mA and 30 mA at 24 V, so check that the connected input draws enough current.


















Reviews