Brand:

EUCHNER SGP1E-2131A-M Plastic Safety Switch, 3+1 Contacts

Description

Overview

Not every guard needs a metal body, and for dry machine rooms and clean production halls the EUCHNER SGP1E-2131A-M offers a lighter option. This safety switch has a housing of reinforced thermoplastic, a 2131 slow-action contact block with three positively driven contacts and one normally open contact, and three M20 x 1.5 cable entries. Its approach direction may be horizontal or vertical and can be rotated in 90 degree steps. Seven Star LLC is an independent supplier serving Oman and the GCC.

What SGP1E-2131A-M means

SGP is the plastic-housing series that shares its actuator range with the SGA, STA, STP and STM switches. The 1 indicates cable-gland connection, E is the head variant, 2131 the contact arrangement and M the cable thread. Article number 097706 identifies the version. As with all switches in the line, the actuator is not included, and the matching S-type actuators are chosen from the accessory list.

Datasheet values of EUCHNER SGP1E-2131A-M

Property Value
Housing Reinforced thermoplastic
Contacts 3 positively driven, 1 NO; slow-action, silver alloy gold flashed
Utilization category AC-15 4 A 230 V; DC-13 4 A 24 V
Thermal current 4 A, fuse up to 4 A gG
Rated voltages 250 V insulation, 2.5 kV impulse
Minimum load 12 V at 10 mA, 1 mA at 24 V
Connection 3 x M20 x 1.5
Forces Actuating 25 N, extraction 25 N, retention 10 N
Insertion depth 24.5 mm
Actuation rate up to 6700 per hour
Mechanical life 2 million cycles
Protection / temperature IP67 / minus 20 to plus 80 degrees C
B10D, mission time 3 million cycles, 20 years

How EUCHNER SGP1E-2131A-M differs from other SGP variants

The SGP family comes in a short list. The SGP1E-2121A-M carries four positively driven contacts, while the SGP1E-3131A-M carries two positively driven and two normally open contacts. The SGP2E-2131ASR11 has the same contact set as the EUCHNER SGP1E-2131A-M but is connected through an 11-pin SR11 plug connector instead of cable glands, and the SGP3E-538ASFM5C2628 uses an M12 plug with a 538 element. The SGP-TW-1E-2131AC-M is a twin version with two actuating heads for double doors. Compared with the metal NX1 switches the SGP has a lower B10D of 3 million cycles but the same 6700 per hour actuation limit and lower forces.

Fitting it to the right machine

The low actuating force of 25 N suits light doors and covers in packaging machines, laboratory equipment, food processing, textile and printing machinery, and enclosed conveyor sections. In the Gulf, plastic switches are common inside air-conditioned control rooms and indoor production halls where chemicals or heavy impact are not expected. For outdoor skids with sand and heat, a metal switch may be more suitable.

Actuator choices

The S-type range includes a standard actuator, an actuator with rubber bush, a version for insertion funnels, and hinged radius types. With the actuator ACTUATOR-S-GT-SN the overtravel is 5 mm, which tolerates modest door play. Two safety screws are supplied with each actuator, and they should be tightened with the stated torque so that the actuator cannot be removed without tools.

Installation checklist

Mount the switch on a flat, rigid surface using the fixing holes, choose the head orientation and fit the actuator so that it enters the funnel without scraping. Conductors of 0.34 to 1.5 square mm go into the terminal block, and unused entries must be sealed. After wiring, check the contact states with the guard open and closed, and run the safety relay through a full test sequence.

Routine care

Look at the actuator tip and the entry slot for scratches, make sure the plastic body has not cracked, and verify the screws. Because plastic can age in strong sunlight and aggressive solvents, replace any switch showing discolouration or brittleness. Record the date of replacement in the maintenance system against the mission time of twenty years.

Why a positively driven contact matters here

A positively driven contact opens by force from the actuator even if another contact in the same block has welded. Three of them in the EUCHNER SGP1E-2131A-M give design freedom: two can feed the two channels of a safety relay and the third can serve a diagnostic input. The normally open contact reports the door position to a controller. This combination replaces two separate devices on many simple doors.

Planning the safety function around the EUCHNER SGP1E-2131A-M

A switch is only one link in a safety function, so the data of the EUCHNER SGP1E-2131A-M must be combined with the logic unit, the output devices and the wiring. The documented B10D of 3 million cycles for guard position monitoring, together with a mission time of 20 years, lets the designer estimate the dangerous failure rate once the annual number of door openings is known. For a door that opens fifty times per shift the cycle count stays far below the limit, and the mission time becomes the governing figure. If the door opens several times each minute, count the cycles instead and plan replacement before the B10D based service interval expires.

Use the positively driven contacts in a two-channel scheme with a safety relay that detects cross-circuits, and keep the signalling contact outside the safety chain. Document the actuator type and the overtravel in the machine file, because the safety distance of the door and the actuator geometry form part of the validation.

Common field problems and remedies

Nuisance trips are usually caused by door sag, vibration or a misaligned actuator, not by the switch itself. If the signal flickers, check that the actuator has full insertion and that the door cannot bounce, then look for loose terminals. Water in the head normally enters through an unused cable entry or a worn gland, so seal every opening to keep the IP67 rating. Where cables are routed across hinges, add strain relief so that conductors are not fatigued. Finally, never bridge or defeat the contacts for convenience; the housing and the tamper-resistant actuator screws are designed to make such manipulation hard.

Ordering notes

State the complete code, the actuator type and the number of cable glands. If your machine needs a plug connector or twin function, mention it, because these are different codes. Seven Star LLC can quote the switch with spare actuators and accessories for delivery in Oman and the GCC.

Related items you may also need: EUCHNER ESM-TE301 Time-Delayed Safety Contact Expansion | EUCHNER ZSM2100 Three-Position Enabling Switch | EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch, M12 | All EUCHNER products.

Documents and quotation

The manufacturer operating instructions for the SGP safety switch are attached to this page. Send your RFQ with EUCHNER SGP1E-2131A-M, the quantity, the actuator you need and the delivery location.

Datasheets & Documents
  • PDF Datasheet EUCHNER SGP1E-2131A-M Plastic Safety Switch, 3+1 Contacts Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER SGP1E-2131A-M Plastic Safety Switch, 3+1

Answers from our engineering team on installation, compatibility and integration.

01What housing material does the EUCHNER SGP1E-2131A-M use?
The housing is made of reinforced thermoplastic with IP67 protection and an ambient range of minus 20 to plus 80 degrees C.
02What contacts does the EUCHNER SGP1E-2131A-M have?
It has a 2131 slow-action block with three positively driven contacts and one normally open contact, with gold-flashed silver alloy surfaces.
03How is the SGP1E-2131A-M different from the SGP2E-2131ASR11?
Both share the 2131 contact set, but the SGP2E version connects through an 11-pin SR11 plug, whereas the SGP1E uses three M20 x 1.5 cable entries.
04Which overtravel is possible with the SGP1E-2131A-M?
With the actuator ACTUATOR-S-GT-SN the overtravel is 5 mm. The actuator is not supplied with the switch.
05What reliability values does the SGP1E-2131A-M list?
The manufacturer gives a B10D of 3 million cycles for guard position monitoring, a mission time of 20 years and a mechanical life of 2 million cycles.