Brand:

EUCHNER CES-A-C5E-01 Non-Contact Unicode Safety Switch

Description

Overview

The EUCHNER CES-A-C5E-01 is a non-contact safety switch that reads a coded actuator by transponder technology and carries its own evaluation electronics. Instead of wiring two mechanical contacts to a relay, the installer connects an 8-pin M12 cable and receives two redundant semiconductor safety outputs plus a separate monitoring output. The device uses unicode evaluation, which means that each actuator is individually coded and the switch accepts only the actuator that has been taught in. Seven Star LLC is an independent supplier serving Oman and the GCC.

What the letters in EUCHNER CES-A-C5E-01 stand for

CES-A is the series of rectangular non-contact switches with integrated electronics. C5 names the housing size and the unicode coding, E marks the version with category 3, and 01 identifies the plug and cable arrangement. Compare this with CES-A-W5H-01, where W5 means multicode and H marks category 4. The manufacturer article number of the unicode switch is 077750. Actuators are separate parts: CES-A-BBA, CES-A-BCA and CES-A-BPA are named for use with this series, and each gives its own switching distance.

Specification of EUCHNER CES-A-C5E-01

Parameter Value
Coding Unicode, additional actuators can be taught in
Safety rating Category 3, PL e, PFH 4.29 x 10 to the minus 8
Safety outputs LA / LB Two p-switching semiconductor outputs, 1 to 400 mA each
Monitoring output OUT Semiconductor, up to 20 mA
Operating voltage 18 to 27 V DC, regulated
Current consumption 80 mA
Discrepancy time up to 120 ms between outputs
Response (risk) time up to 180 ms
Ready delay up to 3 s
Connection M12, 8-pin, shield connectable
Dimensions 131 x 40 x 40 mm
Housing Plastic PBT
Protection IP65 / IP67
Ambient / storage minus 20 to plus 55 / minus 25 to plus 70 degrees C
Minimum distance between switches 80 mm
Mission time 20 years

How EUCHNER CES-A-C5E-01 differs from other CES-A-C5 and W5 variants

The CES-A-C5H-01 uses the same unicode principle but is rated category 4, and the CES-A-C5H-01-EX is an ATEX version with a protective plate for zones 2 and 22. The CES-A-W5H-01 changes the coding to multicode and also achieves category 4. The EUCHNER CES-A-C5E-01 is the category 3 unicode choice, and its PFH value of 4.29 x 10 to the minus 8 is roughly ten times higher than the 3.7 x 10 to the minus 9 listed for the multicode category 4 switch. For many guard doors category 3 is enough, and the lower rating can reduce cost without losing PL e.

Why unicode evaluation matters

A unicode switch is paired with one actuator, which makes manipulation with a spare actuator much harder. If a new actuator must be fitted, it is taught in by a defined procedure, and the earlier one is then no longer accepted. This is the approach recommended when protection against tampering is part of the risk assessment, for instance on machines operated by many people or in areas where bypassing is a known problem.

Typical use cases in Oman and the GCC

Non-contact switches have no mechanical wear and survive washdown, dust and vibration. They are well suited to hinged and sliding guards on packaging lines, bottling plants, automated warehouse systems, pump skid cabinets, small presses and robotic cells. In hot regions the allowed ambient range up to plus 55 degrees C should be checked for cabinets in direct sunlight.

Operating distance and mounting

The switching distance depends on the actuator. With CES-A-BBA or CES-A-BCA, and with CES-A-BPA, the manufacturer gives separate operating-distance diagrams, and when the actuator approaches from the side the minimum distance to the switch must be kept at 4 mm or 6 mm, depending on the actuator, so that the side lobes are not entered. Also leave at least 80 mm between neighbouring switches and keep the dwell time of an actuator inside and outside the range to at least 0.5 s so that internal self-tests can run.

Wiring and commissioning

Supply the switch from a regulated 18 to 27 V DC source that is protected by an external fuse between 0.25 and 8 A, and protect the safety circuit with a 0.4 A medium slow-blow fuse. Both safety outputs LA and LB must be evaluated by the downstream safety controller. After power-up the outputs remain off during the ready delay of up to 3 s. Teach the actuator following the manual, check both LEDs, and test by removing the actuator and confirming the outputs drop within the response time.

Safety data and what it means for validation

The manufacturer states Category 3 and PL e for the guard position monitoring function of the EUCHNER CES-A-C5E-01, with a PFH of 4.29 x 10 to the minus 8 per hour and a mission time of 20 years. These are the numbers a machine designer inserts into the safety function calculation together with the data for the downstream safety controller and any contactors. Because both semiconductor outputs are electrically decoupled and tested internally, the switch can be connected directly to the inputs of a safety PLC or safety relay that accepts OSSD-type signals, without an extra evaluation unit. The monitoring output can be wired to a standard PLC input for diagnostics, but it must never be used as part of the safety chain.

When the application also needs protection against casual manipulation, the unicode coding is an advantage, since a spare actuator taken from another machine is not accepted. Teach-in of a replacement actuator is a controlled procedure, described in the operating instructions, and should be recorded in the maintenance system.

Troubleshooting guide

If the outputs do not switch on, check first that the supply voltage lies between 18 and 27 V DC and that the ready delay of 3 s has elapsed. Confirm that the actuator is the one taught in, that it is within the distance diagram and that no steel part is shifting the active range. A flashing diagnostic LED indicates an error condition; the manual lists the flash codes. Look for damaged cable insulation, loose M12 connectors and wrong pin assignment, and make sure the shield is connected as recommended.

Maintenance

There are no moving parts, so service is limited to cleaning the active face, tightening the fixings and checking the cable. Make sure no ferrous chips or metal covers shift the actuating range, and confirm periodically that the safety controller reports a clean diagnostic state. The ambient limit and the UL note about a Class 2 power supply must be respected.

Ordering notes

Give the complete code and say which actuator you plan to use, since it is not included. Add an 8-pin M12 cable if one is required. For replacement of an older switch, send its nameplate so that the supply voltage and output type can be compared.

Related items you may also need: EUCHNER ZSB054784 Three-Stage Enabling Switch with +/- Buttons | EUCHNER CTM-LBI-BP-U-AZ-SA BiState Guard Locking Switch | EUCHNER STP-TW-3A-2131AC024M Twin Guard Locking Switch | All EUCHNER products.

Documents and quotation

The manufacturer operating instructions for the non-contact CES-A switch family are attached. Please send your RFQ with EUCHNER CES-A-C5E-01, the number of pieces, the actuator you need and the destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet EUCHNER CES-A-C5E-01 Non-Contact Unicode Safety Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CES-A-C5E-01 Non-Contact Unicode Safety

Answers from our engineering team on installation, compatibility and integration.

01Is the EUCHNER CES-A-C5E-01 a unicode or multicode switch?
It is a unicode switch: each actuator is individually coded and the switch only accepts a taught-in actuator, although further actuators can be taught in.
02What safety category does the EUCHNER CES-A-C5E-01 reach?
It is rated Category 3 and PL e according to EN ISO 13849-1, with a PFH of 4.29 x 10 to the minus 8 and a mission time of 20 years.
03What supply and connection does the CES-A-C5E-01 use?
It runs from 18 to 27 V DC regulated with 80 mA current consumption and connects through an 8-pin M12 plug with shield connection.
04What is the minimum spacing between two CES-A-C5E-01 switches?
The manufacturer gives a minimum distance of 80 mm between switches, and an actuator should stay inside or outside the range for at least 0.5 s.
05How is the CES-A-C5E-01 different from the CES-A-W5H-01?
The C5E is unicode and category 3, while the W5H is multicode and category 4 with a lower PFH value.