Crouzet 84137000N GN Solid State Relay 10 A 280 VAC 4-32 VDC
Description
Overview
The smallest relay in the Crouzet GN family is Crouzet 84137000N: a 10 A, single phase, panel-mount solid state relay for 24 to 280 VAC loads with zero cross switching and a 4 to 32 VDC control input. It shares the compact GN housing with the larger 25 to 125 A models, including the aluminium baseplate, the removable IP20 touch-safe cover and the green LED that shows when the input is on. Seven Star LLC is an independent supplier serving Oman and the GCC. We keep this page short on marketing and long on numbers, because the choice between a 10 A relay and its larger neighbours is a thermal and electrical one.
Facts that define Crouzet 84137000N
| Parameter | Crouzet datasheet value |
|---|---|
| Rated load current | 10 A rms with heat sinking |
| Operating voltage | 24 to 280 VAC, 47 to 63 Hz |
| Switching | Zero cross, for resistive loads |
| Transient voltage | 600 V peak |
| Minimum load current | 5 mA rms |
| Off-state leakage | 1 mA rms at rated voltage |
| Minimum dV/dt | 500 V per microsecond |
| Surge, 1 second | 45 A peak at 25 C |
| Surge, one cycle at 50 Hz | 120 A (50 Hz) / 126 A (60 Hz) minimum, 160 A typical |
| On-state drop | 1.2 V peak at rated current |
| I squared t for fusing, half cycle | 78 A2s minimum, 128 A2s typical |
| Junction to case thermal resistance | 2.3 C per W |
| Minimum heatsink at 40 C | 5.3 C per W |
| Control voltage | 4 to 32 VDC, on at 3 V, off at 1 V, 10 to 14 mA |
| Switching delay | Half cycle at most for turn-on and turn-off |
| Isolation | 4000 V rms input to output; 2500 V rms input and output to ground |
| Temperature | Operating minus 40 to plus 80 C; storage minus 40 to plus 100 C |
| Weight | 80 g typical |
| Housing / baseplate | UL94 V-0 housing, aluminium baseplate |
How 84137000N differs from other GN series variants
Three comparisons help most. Against 84137001N, only the control side changes: 20 to 265 VAC instead of 4 to 32 VDC. Against the 25 A relay 84137010N, the same 24 to 280 VAC output is kept but the current rises to 25 A and the minimum heatsink falls from 5.3 to 1.3 degrees per watt. Against the 50 A relay 84137120N, the output voltage range moves to 48 to 660 VAC and the one-second surge capability rises from 45 A to 230 A. If you only need to switch a small heater, a solenoid valve or a signal lamp bank, the 10 A relay is the economical match, as long as the heatsink is respected.
Choosing Crouzet 84137000N for a load
Start with the load. A resistive load of 2 kW at 230 VAC draws about 8.7 A, which is within the 10 A rating, but only with a heatsink that keeps the base plate cool. The datasheet gives a minimum heatsink of 5.3 degrees Celsius per watt at 40 degrees ambient for full current, and even the weakest accessory heatsink in the Crouzet list, 2.2 degrees per watt (26532756N), meets that requirement with margin. At lower current or lower ambient temperature a smaller sink may do, following the derating curves in the datasheet. For capacitive or very inductive loads, the datasheet points you instead to the instantaneous range, such as 84137210N with 25 A at 24 to 280 VAC and 4 to 32 VDC control.
Where Crouzet 84137000N is used in Oman and the GCC
In the field this relay does quiet work. In oil and gas and utilities it controls small heaters in analyser cabinets and instrument enclosures, switches anti-condensation heaters in switchgear and drives alarm beacons from PLC outputs. In water treatment it can pulse small dosing heaters and valves. Packaging and food machinery rely on it for sealing and heating elements that cycle every second, a duty where a mechanical relay would wear out. Summer temperatures in the Gulf reduce the margin available for cooling, so the thermal check matters more than in cooler climates.
Control input behaviour of Crouzet 84137000N
The input is a current limiter, so a PLC transistor output or a 24 VDC relay contact can drive it without a series resistor. The datasheet states a turn-on threshold of 3 VDC, a must-turn-off level of 1 VDC and an input current that stays between 10 and 14 mA across the range. Turn-on and turn-off both complete within half a mains cycle for this zero cross type, which is why the relay waits for the next zero crossing of the load voltage before conducting. That behaviour keeps switching noise low and extends heater life. If the control signal is used below minus 20 degrees Celsius, add 1 V to the minimum turn-on voltage, as the datasheet note instructs.
Wiring Crouzet 84137000N
The load goes to terminals 1 and 2 and the control to 3 (plus) and 4 (minus). The control terminals take 0.75 to 2.5 mm2 conductors, torque 1.2 to 2 N.m, while the load terminals take 1.5 to 10 mm2 solid or 1.5 to 6 mm2 stranded wire with 2 to 3 N.m. Fix the base with the mounting screws at 1.2 to 1.8 N.m over a thin, even layer of thermal grease (26532003) or a thermal pad. A DIN rail adapter (26532764N) is available for rail mounting. Place a semiconductor fuse sized against the 78 A2s minimum I squared t rating in the load circuit.
Commissioning and maintenance
Energise the control with the load disconnected and check that the LED lights between 4 and 32 VDC. Then connect the load and measure the heatsink temperature after thirty minutes at working load; a stable, moderate reading confirms the sizing. Re-torque terminals after the first week and at each outage. Remember the 1 mA off-state leakage: a small neon or LED indicator wired across the load can glow faintly even when the relay is off, and the load must be isolated by a disconnect before maintenance.
Related items you may also need: Siemens 3RT2024-1AP00 SIRIUS Contactor 12 A 5.5 kW | Schneider Electric LC1F185M7 TeSys F 185 A Contactor 220 V AC | Siemens 3RT2023-1AP00 SIRIUS Contactor 9A 4 kW | All Crouzet products.
Documents and quotation
The Crouzet GN series datasheet is attached to this page. To receive a quotation for Crouzet 84137000N, send your RFQ with the quantity, load voltage and current, and any heatsink or DIN rail adapter you need. We reply with availability and lead time for Oman and the GCC.
Datasheets & Documents
- Datasheet Crouzet 84137000N GN Series Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Crouzet is a French maker of control, switching and motion components whose roots go back to a small workshop founded in 1921 by Édouard Crouzet in the Valence area of south-eastern France. Over the following century the name grew from precision mechanics into timers, relays, counters, motors, switches and, from the 1990s on, programmable smart relays. The company today builds electrical control products for industrial machines, buildings and utilities, as well as aerospace and rail components, and it is still based in Valence.
Crouzet company profile
| Founded | 1921, by Édouard Crouzet, in the Valence area, Drôme, France |
|---|---|
| Headquarters | Valence, France |
| Ownership | Part of the InnoVista Sensors group; earlier owned by Schneider Electric (2000 to 2014) |
| Core technology | Programmable smart relays (Millenium), solid state relays, timer, monitoring and counter relays, DC and stepper motors, limit switches and microswitches |
| Typical applications | Pump and fan control, heating, machine sequencing, building services, railway and aerospace equipment |
| Standards | Millenium controllers follow IEC/EN 61131-2 and carry CE, cULus and, on Millenium 3, UL, CSA and GL marks |
Milestones
- 1921: Édouard Crouzet founds the company near Valence.
- 1932-33: The workshop moves to Bourg-lès-Valence.
- 1966: The business becomes Crouzet Automatismes, a public limited company, and its shares are listed on the stock exchange in 1969.
- 2000: Schneider Electric acquires Crouzet Automatismes.
- 2014: Schneider Electric sells its Custom Sensors and Technologies business, in which Crouzet was a brand.
- Today: The range covers logic controllers, solid state relays, timer and monitoring relays, counters, motors and switches.
How a smart relay works
A Millenium logic controller replaces a handful of timers, counters and auxiliary relays with a single programmable box. Field signals from push buttons, float switches or 0 to 10 V sensors arrive on the input terminals. A program, drawn as function blocks, SFC (Grafcet) or Ladder in the free M3 Soft or Crouzet Soft software, combines those signals with timers, counters, comparators and a real-time clock. The result is written to relay or transistor outputs that drive contactors, valves and lamps. The program lives in flash memory and is retained for ten years without power, and a small LCD with a keypad lets operators read states and adjust the parameters you choose to expose. The expandable models add communication and extra I/O modules at the side, and the Evo bases add faster counting, twelve-bit analogue inputs and, in the E versions, Ethernet with Modbus TCP. Selection tip: count inputs and outputs first, then check the supply voltage code, because the last digits of the part number define it.
Where Crouzet products are used in Oman and the GCC
These controllers and relays suit the utility and process plants of the region: booster and transfer pump stations, desalination and wastewater auxiliaries, heat tracing and heater control in oil and gas facilities, HVAC and district cooling plants, and packaging and food machinery. Compact DIN-rail housings and the stated operating range of minus 20 to plus 55 degrees Celsius for Millenium 3 make them practical for panels exposed to Gulf summers.
Crouzet models we list
| Family | Examples |
|---|---|
| Millenium 3 Essential logic controllers | 88970041 (CD12), 88970141 (XD10), 88970161 (XD26) |
| Millenium Evo logic controllers | 88975101 (XDP24), 88975111 (XDP24-E, Ethernet) |
| GN series solid state relays | 84137000N (10 A, 280 VAC), 84137120N (50 A, 660 VAC) |
Ordering Crouzet products: what we need
Send the exact part number from the nameplate or the datasheet, the quantity and the supply or load voltage, because many codes differ only in the last digits. For controllers, say whether you need programming software, a USB or serial cable, a memory cartridge or a communication module; for solid state relays, include the load current and whether a heatsink or DIN rail adapter is needed. Seven Star LLC is an independent supplier serving Oman and the GCC, and we confirm availability and lead time against your RFQ.
Facts checked against the company website, manufacturer datasheets and catalogues, and the French Wikipedia entry on the Crouzet brand, November 2026.
Browse Crouzet products by category: Logic Controllers, Contactors & Overload Relays.
FAQ
Questions about the Crouzet 84137000N GN Solid State Relay 10 A 280 VAC
Answers from our engineering team on installation, compatibility and integration.
01What is the load rating of Crouzet 84137000N?
It switches up to 10 A rms on 24 to 280 VAC at 47 to 63 Hz with zero cross turn-on. The datasheet notes that heat sinking is required, and the minimum load current is 5 mA rms.
02Which control voltage does Crouzet 84137000N use?
The control input is 4 to 32 VDC. It turns on at 3 VDC, must see 1 VDC or less to turn off, draws a minimum of 10 mA and a maximum of 14 mA, and is protected against reversed control polarity down to minus 32 VDC.
03What heatsink is needed for Crouzet 84137000N?
For rated current at 40 degrees Celsius the datasheet gives a minimum heatsink of 5.3 degrees Celsius per watt. All five accessory heatsinks in the datasheet, from 0.9 to 2.2 degrees per watt, are better than this figure.
04How does Crouzet 84137000N differ from the 84137001N?
The code ending in 000N uses a 4 to 32 VDC control input, while the one ending in 001N uses a 20 to 265 VAC control input. Both are 10 A, 24 to 280 VAC zero cross relays in the same GN housing.
05Does Crouzet 84137000N protect against voltage spikes?
The datasheet lists built-in overvoltage protection for the zero cross versions and a transient voltage rating of 600 V peak for this 280 VAC unit. The output may self trigger between 450 and 600 V peak, so it is not suited to capacitive loads.