Eaton ZB32-16 Overload Relay 10-16 A

Description

Eaton ZB32-16 thermal overload relay, 10 – 16 A

The Eaton ZB32-16 (catalog number 278452) is the lowest-range relay in the larger ZB32 frame. Its dial covers 10 to 16 A, a wider window than the ZB12-16, and it is 96 mm deep. It has one N/O and one N/C auxiliary contact, trips to Class 10 A and mounts directly onto the contactor. Seven Star LLC supplies the ZB32-16 in Oman and the GCC.

It is chosen when the starter is built on a mid-size contactor frame but the motor is modest, for instance when a design is standardised on one contactor size for several motor ratings.

Reading the model code ZB32-16

ZB is the Eaton Moeller thermal overload relay series. 32 after it is the frame size (the 12 or 32 reflects the largest current the frame covers), and the number after the hyphen, here 16, is the top of the adjustable range in amperes. The relay is therefore adjustable from 10 to 16 A. A relay from the same frame with a different suffix covers a different current band, so the suffix has to match the motor nameplate.

ZB32-16 technical specifications

Parameter Specification
Manufacturer / part number Eaton ZB32-16 (catalog number 278452)
Series / frame size Eaton Moeller ZB, ZB32
Overload release setting 10 – 16 A
Dimensions / weight 96 mm deep × 67 mm high × 45 mm wide; 0.146 kg
Heat dissipation 5.4 W total, 1.8 W per pole at 16 A
Short-circuit protection, type 2 35 A gG/gL
Short-circuit protection, type 1 63 A gG/gL
UL/CSA branch circuit fuse 100 kA with Class J fuse, max. 35 A (600 V)
Contacts 1 N/O and 1 N/C auxiliary contact
Trip class Class 10 A to IEC 60947-4-1
Phase-failure sensitivity Yes, per IEC/EN 60947 and VDE 0660 part 102
Features Test/off button, trip-free release, manual/auto reset pushbutton
Temperature compensation Continuous, residual error ≤ 0.25 %/K above 40 °C
Rated operational voltage 690 V max.
Impulse withstand voltage 6000 V AC; 4000 V for auxiliary and control circuits
Auxiliary contact ratings AC-15: 1.5 A at 120 V and 230 V, 0.9 A at 400 V; DC-13: 0.9 A at 24 V, 0.75 A at 60 V, 0.4 A at 110 V, 0.2 A at 220 V
Ambient temperature −25 to +55 °C; −25 to +40 °C enclosed
Mounting Direct mounting on the contactor
Main terminals M4, 1.8 Nm; Pozidriv 2 or 1 × 6 mm slotted; strip 10 mm
Control terminals M3.5, 1.2 Nm; strip 8 mm
Approvals listed on sheet CE, UL, CSA, VDE 0660, IEC/EN 60947-4-1

Data comes from the manufacturer specification sheet for this catalog number; verify against the rating plate on the delivered relay.

How the ZB32-16 protects the motor

Each phase passes through a bimetal strip. Motor current heats the strips; if the heating persists beyond the Class 10 A trip curve, the bimetals bend, move a release mechanism and switch the auxiliary contacts. The N/C contact (95/96) is wired into the contactor coil circuit to drop the motor out, and the N/O contact (97/98) can signal an alarm. Temperature compensation is continuous, so the trip point stays stable as the panel warms or cools. The relay is also sensitive to phase failure: an unbalanced current causes a faster trip, which protects the motor if one supply phase is lost.

The yellow dial sets the trip current inside the range. A test/off button checks the contact wiring, and the reset button can be set to manual or automatic. Trip-free release means the relay cannot be held closed against a fault by keeping the reset pressed.

Where the ZB32-16 fits in the system

The ZB32 frame fits the mid-size contactors from the DILM17 upwards, for example DILM17, DILM25 and DILM32 sizes, with ZB32-16 as the bottom of the range, followed by ZB32-24 and higher. Compared with ZB12-16, the ZB32-16 allows a lower setting down to 10 A and permits higher upstream fuses: the sheet gives 35 A gG/gL for type 2 and 63 A gG/gL for type 1 coordination. Confirm the combination in the manufacturer selection table.

Selection checklist for the ZB32-16

  • Set the dial to the motor nameplate current; the usable window is 10 – 16 A.
  • Use the N/C contact in the control circuit and keep the N/O for signalling only.
  • Check that the contactor frame accepts this relay by direct mounting; otherwise a separate mounting kit is needed.
  • Match the short-circuit device to the type 1 or type 2 values shown above.
  • Choose manual reset for pumps and conveyors where an unattended restart is a hazard.
  • Remember the relay protects the motor against overload, not against short circuit.

Installation and commissioning of the ZB32-16

Slide the relay onto the contactor terminals so the three power pins engage, then tighten the main screws to 1.8 Nm. Control wires go to terminals 95/96 and 97/98 with 1.2 Nm. After wiring, set the dial to the nameplate current, press test to confirm the N/C opens, then reset. During commissioning measure the actual motor current and trim the setting if it differs from the nameplate. Periodic checks should include terminal tightness and a trip test after any long outage.

Typical applications in Oman and the GCC

A relay set between 10 and 16 A is common on 400 V pumps and fans of 5.5 to 7.5 kW in a standardised starter design. Typical places are cooling-water pumps in power and desalination plants, fire-water jockey pumps, ventilation blowers and conveyors in plants around Sohar, Duqm and Salalah. Panels in outdoor enclosures benefit from shading, since relay heat adds to the panel load.

Family table around ZB32-16

Relay Setting range Frame
ZB12-16 12 – 16 A ZB12
ZB32-16 10 – 16 A ZB32
ZB32-24 16 – 24 A (see site listing) ZB32
ZB32-32 24 – 32 A (see site listing) ZB32

Information to send with an RFQ for the ZB32-16

  • Exact part number: ZB32-16
  • Quantity and delivery location
  • Motor power, voltage and nameplate current
  • Contactor type the relay will be mounted on
  • Starting method and whether manual or auto reset is needed

Documents and quotation

The manufacturer specification sheet for ZB32-16 is attached on this page for reference.

Send the part number ZB32-16 with the quantity and we will confirm availability and lead time. Seven Star LLC supplies Eaton products in Oman and the GCC from Muscat.

Other Models in the Eaton Zb Overload Range

Seven Star LLC supplies models from the Eaton Zb Overload range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton ZB12-16 Overload Relay 12-16 AContactors & Overload RelaysView details
Eaton ZB32-16 Overload Relay 10-16 AContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton ZB32-16 Overload Relay 10-16 A

Answers from our engineering team on installation, compatibility and integration.

01What is the setting range of the ZB32-16?
10 to 16 A, adjustable on the front dial, with Class 10 A tripping and phase-failure sensitivity.
02How does the ZB32-16 differ from the ZB12-16?
It is in the larger ZB32 frame, 96 mm deep, with a lower minimum of 10 A and higher permitted fuses of 35 A type 2 and 63 A type 1.
03What auxiliary contacts does the ZB32-16 have?
One N/O and one N/C, the N/C intended for the contactor coil circuit, rated 1.5 A at 230 V AC-15.
04Can the ZB32-16 reset automatically?
Yes. The reset pushbutton can be set for manual or automatic reset and the release is trip-free.
05What terminals does the ZB32-16 use?
M4 main terminals at 1.8 Nm and M3.5 control terminals at 1.2 Nm, with 1 to 6 mm² solid main conductors.