Brand:

EUCHNER CET2-AR-CRA-CH-50X-SG-110082 Multicode Guard Locking Switch

Description

Overview

Machine builders who need a compact interlock that keeps a guard shut while power is applied will find the EUCHNER CET2-AR-CRA-CH-50X-SG-110082 a straightforward answer. It is a member of the CET-AR range of RFID safety switches with guard locking, and it is configured with multicode evaluation, an open-circuit current locking mechanism and two M12 plug connectors. The order number is 110082.

The word multicode matters. Instead of learning one unique actuator, this switch only checks that the approaching actuator is a type the system can detect. The coding level is therefore low, and every suitable actuator is accepted. That keeps commissioning simple and makes actuator replacement trivial, which is attractive on repetitive machine series and on service stock where spares are shared.

Seven Star LLC is an independent supplier serving Oman and the GCC. We can quote the EUCHNER CET2-AR-CRA-CH-50X-SG-110082 together with the matching actuator and M12 cables for Omani and GCC projects.

EUCHNER CET2-AR-CRA-CH-50X-SG-110082 at a glance

Parameter Value
Series CET-AR, RFID transponder coding, with guard locking
Order number 110082
Coding Multicode (low coding level)
Locking principle Open-circuit current, power on to lock
Unlocking By spring force when solenoid power is removed
Connections 2 x M12 plug connector, 5-pin and 8-pin
Monitoring output OUT for guard locking
Locking force Fmax / Fzh 6500 N / 5000 N
Safety classification Category 4, PL e, SIL 3
PFH, guard lock monitoring 3.1 x 10 to the power of minus 9 per hour
Supply UB 24 V DC, minus 15 % to plus 15 %
Solenoid supply UCM 24 V DC, minus 15 % to plus 10 %
Current ICM / IB 450 mA / 80 mA
Solenoid power 11 W at 100 % duty
Safety outputs 2 semiconductor outputs, p-switching, short-circuit proof
Output current per safety output 1 to 200 mA
Discrepancy time Max 10 ms
Off-state current Max 0.25 mA
Risk time Max 400 ms, plus 5 ms per extra device
Ambient temperature minus 20 to plus 55 degrees C
Degree of protection IP67 inserted and screwed tight
Mechanical life 2 x 10 to the power of 6 operations
Housing / ramp Die-cast aluminium / stainless steel

Understanding open-circuit current locking

With the open-circuit current principle the guard stays locked as long as the solenoid is powered. When the supply to the guard locking solenoid is interrupted, a spring unlocks the guard. EUCHNER also calls this electrical guard locking. The consequence is simple and important: if power disappears, the door can be opened.

That makes this version appropriate where the hazard stops quickly or where a separate means prevents access to a still-moving machine, for instance a drive with a short run-down time controlled by a safety function. When a load can coast for a long time and a person might be hurt if the guard opens at a power failure, the risk assessment normally points to the closed-circuit variants of the family. Selecting between the two is a design decision for the machine builder.

How EUCHNER CET2-AR-CRA-CH-50X-SG-110082 differs from other CET-AR variants

Set next to the 129491 version, the EUCHNER CET2-AR-CRA-CH-50X-SG-110082 replaces the Unicode coding with multicode, replaces the spring-locked bolt with an open-circuit current solenoid, and replaces the single 19-pin M23 connector with a pair of M12 connectors. The 8-pin connector X1 carries the enable inputs IA and IB, supply UB, the safety outputs OA and OB, the monitoring output OUT and the reset input. The 5-pin connector X2 carries the solenoid supply UCM with its 0 V and the two LED inputs.

The protection class is IP67, whereas the M23 versions are listed at IP65 and IP67. There is no teach-in input, no door position output and no escape release in this configuration, so the page shows fewer signals to wire. The electrical performance and the safety figures, Category 4, PL e and SIL 3, are the same as other CET-AR units.

Typical applications

Smaller guarded cells in the Gulf region often use switches of this style: robotic loading cells in fabrication shops, laboratory automation, bottle and can packaging lines, and testing rigs used by contractors who service pumps and valves for oil and gas plants. The switch is also found on utility workshop machines such as honing, winding or balancing equipment where the guard locking prevents the door opening during a short but dangerous run-down.

Because the housing is die-cast aluminium and the ramp is stainless steel, it tolerates the dust and coolant mist typical of machine shops. The degree of freedom of plus or minus 5 mm in X and Y and plus or minus 4 mm in Z gives some tolerance on door alignment, which is helpful on large sliding guards that move slightly with temperature.

Actuators, cables and compatibility

The actuator is ordered separately. EUCHNER lists the CET-A-BWK-50X (order 096327) and the CET-A-BWR-50X-170115, which has improved properties for harsh surroundings including contamination and swarf. Both include four M5x16 safety screws. For the cables, the product page shows M12 female-to-male cables with 5 pins in lengths such as 1.5 m, 5 m, 10 m and 20 m, in PUR or PVC, with some in the AIDA standard.

Wiring for the EUCHNER CET2-AR-CRA-CH-50X-SG-110082 follows the pin tables on the data sheet. X1.1 is enable input IB and X1.2 is UB, then X1.3 and X1.4 are OA and OB, X1.5 is OUT, X1.6 is IA, X1.7 is 0 V UB and X1.8 is RST. On X2, pin 1 is 0 V UCM, pins 2 and 3 are LED 1 and LED 2, pin 4 is UCM and pin 5 is not used because this version has no feedback loop and no teach-in input.

Commissioning checklist

  • Check that UB and UCM are both within their tolerance bands and fused externally within 0.25 to 8 A and 0.5 to 8 A.
  • Confirm that outputs with inductive loads have a free-wheeling diode.
  • Wait for the ready delay of 10 s after switching on before testing the guard.
  • Close the door and verify that the solenoid locks it only while powered, then remove power and confirm the guard releases.
  • Measure the safety output levels: HIGH is UB minus 1.5 V to UB, and LOW is 0 to 1 V.
  • Record the risk time of max 400 ms plus 5 ms per additional device in the stopping time documentation.

Care and servicing

Keep the ramp area clear of swarf and sticky deposits. Look over the cable entries and M12 connectors for damage and make sure the knurled nuts are tight, since the degree of protection depends on screwed-tight connections. If a door starts to bind, realign the actuator rather than forcing it, as the approach speed should stay below 20 m/min.

Replacing a unit is simple because multicode needs no teach-in. Even so, run the function test every time a switch or actuator is exchanged, and document it for the safety file.

Related items you may also need: EUCHNER STP-TW-3A-2131AC024M Twin Guard Locking Switch | EUCHNER ZSB054784 Three-Stage Enabling Switch with +/- Buttons | EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch, M12 | All EUCHNER products.

Documents and quotation

The CET-AR data sheet supplied with this page lists the dimensions, electrical values and safety figures. To obtain a price and lead time for the EUCHNER CET2-AR-CRA-CH-50X-SG-110082, send an RFQ to Seven Star LLC with the part number CET2-AR-CRA-CH-50X-SG-110082, the required quantity and your site location in Oman or the GCC, and state whether you also need actuators, M12 cables and a safety relay.

Other Models in the CET AR Range

Seven Star LLC supplies models from the CET AR range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 Guard Locking Safety SwitchSafety Switches & Guard LockingView details
EUCHNER CET2-AR-CRA-CH-50X-SG-110082 Multicode Guard Locking SwitchSafety Switches & Guard LockingYou are viewing this model
Datasheets & Documents
  • PDF Datasheet EUCHNER CET2-AR-CRA-CH-50X-SG-110082 Multicode Guard Locking Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CET2-AR-CRA-CH-50X-SG-110082 Multicode

Answers from our engineering team on installation, compatibility and integration.

01What is the main difference of the CET2 110082 compared with Unicode CET versions?
It uses multicode evaluation with a low coding level, so any suitable CET actuator is detected, and no actuator needs to be taught in.
02Will the door open if the power fails?
Yes. This variant uses the open-circuit current principle, so the guard is locked while the solenoid is powered and a spring unlocks it when power is interrupted.
03What connectors does this switch have?
It has two M12 plug connectors, one 5-pin for the solenoid supply and LEDs, and one 8-pin for the supply, inputs, safety outputs and the OUT monitor.
04Which safety level does the device reach?
EUCHNER lists Category 4 and PL e for guard lock monitoring, with SIL 3 under EN IEC 62061, using two redundant semiconductor outputs.
05Is the actuator included in the delivery?
No. Order the actuator separately, for example the CET-A-BWK-50X or the CET-A-BWR-50X-170115 listed by EUCHNER for the CET series.