Brand:

EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 Guard Locking Safety Switch

Description

Overview

The EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 is a transponder-coded safety switch with guard locking from EUCHNER, built for movable guards that must stay shut while a hazardous machine movement is still running. It reads an RFID actuator through a stainless steel ramp head, holds the door with a spring-loaded bolt and only releases it when the solenoid receives power. That behaviour is known as the closed-circuit current principle, or power to unlock, and it is the reason this variant is chosen when a power failure must never open a door above a rotating or coasting load.

This particular order number, 129491, is a configured version with a C number of C2467. According to the EUCHNER product page that code stands for a Unicode device without a teach-in input, combined with a long escape release and a lockout mechanism. Each of those three details changes how the unit behaves on site, so they are explained in the sections below rather than hidden in the order code.

Seven Star LLC supplies the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 for projects across Oman and the GCC. Seven Star LLC is an independent supplier serving Oman and the GCC. Contact us with the full part number when you need the exact configuration, because several near-identical CET codes exist and they are not interchangeable.

Key features of the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491

  • RFID transponder coding with Unicode evaluation: each actuator is uniquely coded and the switch only accepts the actuator that was taught in last.
  • Closed-circuit current guard locking, so the guard is held by spring force and unlocked by solenoid force.
  • Two redundant semiconductor safety outputs, OA and OB, with internal monitoring and test pulses.
  • Separate monitoring outputs: OUT reports the guard locking state and OUT D reports the door position.
  • Locking force Fmax of 6500 N, and a rated holding force Fzh of 5000 N, calculated as Fmax divided by 1.3.
  • Die-cast aluminium housing with a stainless steel ramp and degree of protection IP65 and IP67 when inserted and screwed tight.
  • 19-pin M23 plug connector (RC18) with a freely configurable red LED 1 and green LED 2 in addition to the STATE and DIA diagnostic LEDs.
  • Horizontal approach direction that can be turned in 90 degree steps at installation.

Technical specifications of EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491

Parameter Value
Product family CET-AR transponder-coded safety switch with guard locking
Order number 129491
C number C2467
Coding Unicode, no teach-in input
Guard locking principle Closed-circuit current (power to unlock)
Locking force Fmax / Fzh 6500 N / 5000 N
Safety rating Category 4, PL e (EN ISO 13849-1), SIL 3 (EN IEC 62061)
PFH value, guard lock monitoring 3.1 x 10 to the power of minus 9 per hour
Mission time 20 years
Operating voltage UB 24 V DC, minus 15 % to plus 15 %, reverse polarity protected
Solenoid voltage UCM 24 V DC, minus 15 % to plus 10 %
Current consumption ICM 450 mA, IB 80 mA
Solenoid power / duty cycle 11 W / 100 %
External fuse 0.5 to 8 A (UCM), 0.25 to 8 A (UB)
Safety outputs OA / OB Semiconductor, p-switching, short-circuit proof, 1 to 200 mA each
Discrepancy time / turn-on time Max 10 ms / 400 ms
Monitoring outputs OUT and OUT D p-switching, 1 to 50 mA
Risk time (EN 60947-5-3) Max 400 ms, plus 5 ms per additional device
Ready delay / switching frequency 10 s / max 0.5 Hz
Tolerances X / Y / Z plus or minus 5 mm / 5 mm / 4 mm
Approach speed Max 20 m/min
Ambient temperature (UB 24 V DC) minus 20 to plus 55 degrees C
Storage temperature minus 25 to plus 70 degrees C
Degree of protection IP65 / IP67
Mechanical life 2 x 10 to the power of 6 operations
Connection 1 x plug connector M23, 19-pin, RC18
Escape release 105 mm long, tool-free
Housing / ramp material Die-cast aluminium / stainless steel

How CET3-AR-CRA-AH-50F-SH-C2467-129491 differs from other CET-AR variants

The CET family is large, and the suffix of each code matters. Compared with the multicode CET2 version 110082, the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 uses Unicode coding, which means the switch recognises one taught-in actuator instead of any actuator of the correct type. Where the CET2 unit uses the open-circuit current principle with two M12 connectors and IP67, this unit uses a spring-locked bolt, one 19-pin M23 connector and IP65 or IP67.

Compared with the CET1 version 110943, whose C number is C2312, the C2467 configuration removes the teach-in input J on pin 13, which must instead be tied to 0 V, and it adds the lockout bar. EUCHNER states that the lockout bar is not a safety function and that a device fitted with it has no auxiliary release. Check this carefully when a drawing calls for an auxiliary release key.

Where the switch is used in Oman and the GCC

Guard locking with a power-to-unlock bolt suits machines whose dangerous motion continues after the stop command: crushers, mixers, centrifuges, long conveyor transfer stations, packaging lines and automated pipe handling cells. In the Gulf region these appear in fabrication yards, bottling and food plants, water treatment skid assembly and the workshops that support oil and gas maintenance. The high Fzh value of 5000 N is useful on heavy sliding doors and on hinged doors that are pushed by operators or by stray material.

The lockout bar is a practical addition on large walk-in cells where a technician could be inside while a colleague closes the door. It lets the person inside block the bolt mechanically as an organisational aid. Because it is not a safety function, the risk assessment still needs a proper access procedure, but it reduces the chance of someone being shut in.

Selection and compatibility notes

An actuator is not part of the delivery. The EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 works only with the CET actuators designated for it. The page lists the CET-A-BWK-50X, order number 096327, and the CET-A-BWR-50X-170115 with improved properties for harsh surroundings such as swarf or contamination. Each actuator comes with four M5x16 safety screws. Because the device is Unicode coded, a replacement actuator has to be taught in during commissioning, and the last taught-in actuator is the only one accepted.

Mounting is possible in any orientation. The tolerance window of plus or minus 5 mm in X and Y and plus or minus 4 mm in Z lets the actuator enter the ramp even when the door sags slightly. Keep the approach speed below 20 metres per minute, and avoid using the guard as a door stop, because the locking bolt is not intended to absorb the energy of a slammed door.

For connection, EUCHNER lists a range of M23 cables with an angled or straight 19-pin connector and cable lengths from 1.5 m upward. Confirm the exact cable code against your terminal plan before ordering.

Wiring and commissioning

The 19-pin connector carries both supply voltages and all signals. Pin 1 supplies the solenoid at 24 V DC and pin 18 is its 0 V, while pin 6 and pin 19 feed the electronics. Enable inputs IA and IB sit on pins 2 and 3, the safety outputs OA and OB on pins 4 and 5, and the reset input on pin 7. The door position output OUT D is on pin 8 and the guard lock output OUT is on pin 10. Pin 12 is functional earth and must be tied to 0 V, as must pin 13 for this teach-in-free version. Pin 14 must stay open and must not be connected to 0 V.

Commissioning begins with the actuator taught in under the procedure in the operating instructions, followed by a check that both safety outputs reach the HIGH level of UB minus 1.5 V only when the door is closed and locked. Allow the 10 second ready delay after power-up before testing. Outputs driving inductive loads need a free-wheeling diode, and the supply for UCM should be fused externally within the stated range.

Inspection and maintenance

Inspect the ramp and actuator at regular intervals for chips, paint or sticky residue that could stop the bolt entering fully. Check that the mounting screws are tight and that the actuator has not shifted relative to the ramp. Look at the STATE and DIA LEDs after each service because they report the status and diagnostics of the unit, and clear any error before returning the machine to production.

Do not use the escape release as a routine opening method. It is intended to free a person inside the danger zone without tools, and any use should be logged, with the lock function checked afterwards. When a unit has reached the end of its rated mechanical life of two million operations, replace the whole switch and actuator as a matched set.

Related products and ordering notes

For safety evaluation, CET units are often combined with a safety relay or a modular controller that reads OA and OB. Where the stated discrepancy time and risk time matter, these figures should be used in the stopping-time calculation for the machine. If your application does not need a Unicode coded switch, ask us about the multicode CET2 or the CET1 configuration with teach-in, noting that each has different connectors.

When you request a quotation for the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491, quote the full code including the order number 129491 and the C number, plus the quantity and the actuator you need. We can then confirm the configuration against the manufacturer data.

Related items you may also need: EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V | EUCHNER MGB2-H-BA1A3-R Handle Module | EUCHNER MSC-CB-AC-FI8FO2 Modular Safety Controller Base Unit | All EUCHNER products.

Checklist before ordering the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491

  • Before ordering the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
  • Our team confirms the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 code, condition and lead time in writing before any order is placed.
  • The datasheet attached to this page is the reference for the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 dimensions, ratings and wiring.
  • The EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 is listed in our safety switches & guard locking range and ships to sites across Oman and the GCC.
  • Spare quantities of the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 are worth planning for critical duty so that a failure does not stop production.

Documents and quotation

The data sheet for the CET-AR family accompanies this page, and the full operating instructions are available from the manufacturer’s download area. Send your RFQ with the part number EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491, the quantity and the delivery destination, and Seven Star LLC will return a quotation with the lead time. Please also state whether you need actuators and cables so that the whole interlock set arrives together.

Datasheets & Documents
  • PDF Datasheet EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 Guard Locking Safety Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CET3-AR-CRA-AH-50F-SH-C2467-129491 Guard

Answers from our engineering team on installation, compatibility and integration.

01What does the C2467 code mean on this CET3 switch?
The EUCHNER page describes C2467 as a Unicode device without a teach-in input, with a long escape release and a lockout mechanism. It is a configured variant of the CET-AR series.
02Does this switch lock the door when power is lost?
Yes. It works on the closed-circuit current principle, so the bolt is held by spring force and the solenoid must be energised to unlock the guard.
03Is an actuator included with the switch?
No. The actuator must be ordered separately. EUCHNER lists the CET-A-BWK-50X and the CET-A-BWR-50X-170115 as suitable actuators for the CET family.
04What safety level can this device reach?
The product page states Category 4 and PL e under EN ISO 13849-1, and SIL 3 under EN IEC 62061, based on two redundant semiconductor safety outputs.
05Does the lockout bar replace a safety function?
No. EUCHNER states the lockout bar is not a safety function, and the device with the lockout bar has no auxiliary release.