- Automation & ControlView all 3,138 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: EUCHNER
EUCHNER TZ1RE024M Guard Locking Switch, Head Right
Description
Overview
Handing matters on a safety switch: if the head faces the wrong way relative to the door hinge, the cable run and the bolt approach both become awkward. The EUCHNER TZ1RE024M solves that for guards that are best served from the right-hand side, because its actuating head is fitted on the right. In every other respect it is the same guard locking switch as the left-hand TZ1LE024M, with a spring lock, a 24 V solenoid and an auxiliary release on the front. Seven Star LLC is an independent supplier serving Oman and the GCC.
Meaning of RE in the EUCHNER TZ1RE024M code
Read the code from the left. TZ is the series, 1 is the version with the standard approach direction, R states that the actuating head sits on the right, and E marks the type of door and lock monitoring contact block. Then 024 gives the 24 V AC or DC solenoid and the final M indicates one M20 x 1.5 cable entry. The head can also be turned in steps of 90 degrees, according to the description, so the horizontal approach direction can be adapted at installation, and the product page refers to the closed-circuit current principle used by all of these codes.
Data sheet values for EUCHNER TZ1RE024M
| Item | Value |
|---|---|
| Actuating head | Fitted on the right, adjustable in 90 degree steps |
| Door monitoring | 1 positively driven contact + 1 NO contact (type 528) |
| Lock monitoring | 1 positively driven contact + 1 NO contact (type 528) |
| Solenoid | 24 V AC/DC, minus 15 to plus 10 percent, 10 W, 100 percent duty |
| Thermal rated current | 4 A (2 A above 70 degrees C) |
| Switching categories | AC-15 at 4 A 230 V; DC-13 at 4 A 24 V |
| Locking force | 2000 N maximum, 1500 N holding force |
| Release | Auxiliary release on the front, tool or key operated |
| Cable entry | M20 x 1.5 |
| Degree of protection | IP67 |
| Ambient temperature | minus 25 to plus 80 degrees C |
| Life | 1 x 10 to the sixth operations; up to 1200 actuations per hour |
Left or right, and how EUCHNER TZ1RE024M differs from other TZ variants
Compared with TZ1LE024M the only change is the side of the head, and the same bolt series TZ-A is used on both. Against the TZ1RE024MVAB, which has the 2131 and 3131 contact blocks, this switch gives fewer contacts but a simpler wiring plan. Variants ending 110M or 220M change the solenoid to mains voltage, and codes with RC18, SR6, SR11 or BHA replace the cable gland with a plug connector for faster replacement. Pick the right-hand head when the hinge is on the opposite edge of the door or the cable duct comes from the right.
Where it is used
This switch type is found on guard doors of machines that coast down after the drive is switched off, for example grinders, spindles, mixers and conveyors feeding robots. Contractors and machine builders in the Gulf region use the TZ because the locking is maintained when the supply fails, and because the housing is protected to IP67 against dust and spray. It is a common sight on sawmills and food equipment too.
Mounting the right-hand head
Position the switch so the bolt meets the head squarely and the door does not strike the housing. Orient the head before tightening, then wire the contacts to the safety relay or controller according to the wiring diagram for contact types 528H. Keep the supply at the stated tolerance and fuse it to 4 A gG at most. Protect the auxiliary release from misuse, check the red and green LEDs, and verify that the lock engages when the door is closed and the solenoid is de-energised.
Routine checks
At each inspection, test the door and lock monitoring contacts by opening the guard, confirm the release works and examine the head opening for dirt or metal chips. Replace the bolt if its tip is worn. The safety values for guard position monitoring include a B10d of 3 million with a mission time of 20 years, which designers use when calculating performance level.
Selecting EUCHNER TZ1RE024M
The bolt is not part of the delivery. Confirm the door hinge side, the solenoid voltage and whether a connector version is preferred, then quote with the exact code EUCHNER TZ1RE024M.
Practical points when specifying a right-hand TZ
Machine builders often standardise on one hand for all doors, but real layouts rarely allow it. Doors hinged on the left, doors with a cable duct on the right side of the frame, and covers at the end of a conveyor each favour a particular head position. Specifying the EUCHNER TZ1RE024M where the right-hand head is the natural choice saves a bracket and avoids a cable crossing the door opening. Think also about the actuator: a straight bolt suits a door that closes straight in, whereas a door that swings on a hinge may need a radius or bent actuator from the accessory list. Before ordering, sketch the door movement, mark the bolt path, and check that the lead-in has enough tolerance for the door to sag slightly over the years.
The same quantities used to design the circuit should be recorded on the machine documentation: the solenoid supply of 24 V, the fuse rating of 4 A gG at most, the maximum approach speed of 20 m/min and the maximum of 1200 operations per hour. The operating instructions also remind users that a risk assessment must be done for the machine, and that the safety function depends on the complete system, including the evaluation device, wiring and the stop-time of the hazard, not on the switch alone. Keep the instructions with the machine file so that later maintenance staff know the original assumptions.
Related items you may also need: EUCHNER STP-TW-3A-2131AC024M Twin Guard Locking Switch | EUCHNER MSC-CB-AC-FI8FO2 Modular Safety Controller Base Unit | EUCHNER RPS-M-2131SR175M Emergency Stop Rope Pull Switch | All EUCHNER products.
Documents and quotation
The TZ operating instructions are attached to this page, covering installation, electrical connection and safety data. Please send your RFQ with EUCHNER TZ1RE024M, the quantity and your delivery location in Oman or the GCC.
Other Models in the Tz Range
Seven Star LLC supplies models from the Tz range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER TZ1LE024M Guard Locking Safety Switch, 24 V | Safety Switches & Guard Locking | View details |
| EUCHNER TZ1RE024M Guard Locking Switch, Head Right | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER TZ1RE024M Guard Locking Switch, Head Right Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER TZ1RE024M Guard Locking Switch, Head Right
Answers from our engineering team on installation, compatibility and integration.
01How does the EUCHNER TZ1RE024M differ from the TZ1LE024M?
The R in RE places the actuating head on the right, while the LE type has it on the left; the electrical data and ratings are the same.
02Can the head of the TZ1RE024M be rotated?
Yes. The description states the approach direction is horizontal and can be adjusted in 90 degree steps.
03What supply does the TZ1RE024M solenoid need?
It needs 24 V AC or DC with a tolerance of minus 15 to plus 10 percent and draws 10 W at 100 percent duty cycle.
04What cable entry does the TZ1RE024M have?
It has one cable entry of M20 x 1.5 for wire cross sections from 0.34 to 1.5 mm2.
05Does the TZ1RE024M have an auxiliary release?
Yes. A front auxiliary release lets personnel unlock the guard with a tool or key after a malfunction such as power failure.


















Reviews
There are no reviews yet.