EUCHNER NZ1VZ-3131E-M Metal Safety Switch, 2 + 2 Contacts
Description
Overview
When a safety relay needs more than a single break path from a guard door, the EUCHNER NZ1VZ-3131E-M is the metal-body answer. It keeps the proven NZ.VZ housing of anodized die-cast alloy, but its 3131 slow-action element offers two positively driven contacts and two normally open contacts in one head. That makes it a convenient single device for a dual-channel door circuit that also reports its position to a controller. Seven Star LLC is an independent supplier serving Oman and the GCC.
Reading the EUCHNER NZ1VZ-3131E-M order code
NZ1VZ points to the NZ.VZ safety switch with one M20 x 1.5 entry. The block 3131 names the contact arrangement, which the manufacturer lists as two positively driven contacts and two normally open contacts. The letter E refers to the head design and M to the cable-gland thread. The article number linked to the code is 082122. The switch is supplied without an actuator.
Key data table for EUCHNER NZ1VZ-3131E-M
| Item | Value |
|---|---|
| Contact arrangement | 3131, 2 positively driven plus 2 NO contacts |
| Switching principle | Slow-action |
| Approach direction | Horizontal, rotatable in 90 degree steps |
| Rated currents | AC-15 4 A at 230 V; DC-13 4 A at 24 V; thermal 4 A |
| Fuse | up to 4 A gG |
| Insulation / impulse voltage | 250 V / 2.5 kV |
| Minimum load | 12 V at 10 mA |
| Cable entry | 1 x M20 x 1.5 |
| Actuating / extraction / retention force | 35 N / 35 N / 8 N |
| Insertion depth | 52 mm |
| Mechanical life | 2 x 10 to the sixth cycles |
| Protection | IP67 |
| Temperature | minus 25 to plus 80 degrees C |
| B10D / mission time | 4.5 million / 20 years |
Why choose the 3131 element over 528 or 2131
Compared with the NZ1VZ-528E-M, which has one positively driven contact and one normally open contact, the EUCHNER NZ1VZ-3131E-M doubles both paths. This lets one switch serve two safety channels while the two normally open contacts supply door-closed signals to a PLC or to a second relay. The NZ1VZ-2131E-M carries three positively driven contacts and one normally open contact, so it is the better pick when three break paths are needed rather than two. All three share the 52 mm insertion depth, the 35 N actuating force and the IP67 enclosure, so they can be exchanged on the same bracket without changing the actuator.
Typical uses in Oman and the GCC
The two-and-two layout is popular on machines where a monitored guard feeds a dual-channel relay and a separate controller needs to know that the door is closed. Examples include plastic injection moulding cells, can and bottle filling lines, rotating screens at wastewater plants, packaging machinery in food factories and the guards of workshop lathes and presses. The metal body suits harsh handling and the occasional impact, and the IP67 rating handles washdown and dusty halls.
Actuators and door geometry
Pair the switch with the right actuator for the door type. The straight stainless-steel ACTUATOR-Z-G gives 4 mm of overtravel, ACTUATOR-Z-GN gives 16 mm, and radius actuators are listed for doors hinged left, right, at the top or at the bottom. A solid stainless version is available where cleaning chemicals are aggressive. The actuator is not included with the switch, so add it to the enquiry and state the door radius if a hinged type is required.
Installation and testing
Fix the body to a rigid part of the frame and turn the head to the required approach direction before connecting conductors of 0.34 to 1.5 square mm. Wire the two positively driven contacts to the safety relay inputs, and the normally open contacts to the monitoring input. Because the switch is not an end stop, fit a separate door stop. After installation, check each contact with a meter while opening the door, then verify the relay response and record the result in the commissioning log.
Plan the cable routing so that the head cannot be pulled by a heavy loop, and label both channels clearly on the terminal block, which saves time during fault finding later.
Service hints
Look for a loose actuator, a damaged slot guide, or a head that has moved. Keep the cable gland tight, replace brittle seals and clean away chips. If a door slams, soften the stop rather than letting the actuator take the shock, because the retention force is only 8 N and the insertion depth of 52 mm is intended to be reached gently.
Safety function and diagnostic coverage
A positively driven contact is one whose opening is forced by the actuator movement, even if a contact element has welded, and that is why the EUCHNER NZ1VZ-3131E-M can be used in circuits that must reach a high performance level. The manufacturer gives a B10D value of 4.5 million cycles for guard position monitoring and a mission time of 20 years, measured at DC-13 with 100 mA at 24 V. Designers insert these values into the calculation for the whole safety function, together with the data of the relay and the wiring. With two positively driven contacts routed to separate relay inputs and cross-fault detection in the relay, the structure meets the demand of dual-channel monitoring on one door.
Keep in mind that the values only hold when the stated load is respected, so avoid inductive loads directly on the contacts and use the relay or a contactor with suppression as the load instead.
Ordering the EUCHNER NZ1VZ-3131E-M
Send the complete code and the article number if known. Many users order an actuator, two cable glands and a spare switch at the same time. If the existing installation uses a different contact block, quote that code as well so that substitutions can be checked against the manufacturer documentation.
Related items you may also need: EUCHNER RPS-M-2131SR175M Emergency Stop Rope Pull Switch | EUCHNER CES-IA-BR-U-C07-SA Non-Contact Safety Switch Set | EUCHNER ZSM2100 Three-Position Enabling Switch | All EUCHNER products.
Documents and quotation
The operating instructions for the NZ.VZ safety switch are attached to this page. Please send your RFQ with EUCHNER NZ1VZ-3131E-M, the quantity, any actuator requirement and the delivery location in Oman or the GCC.
Other Models in the Nzvz Range
Seven Star LLC supplies models from the Nzvz range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| EUCHNER NZ1VZ-528E-M Metal Safety Switch, 1 NC + 1 NO, M20 | Safety Switches & Guard Locking | View details |
| EUCHNER NZ1VZ-3131E-M Metal Safety Switch, 2 + 2 Contacts | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet EUCHNER NZ1VZ-3131E-M Metal Safety Switch, 2 + 2 Contacts Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER NZ1VZ-3131E-M Metal Safety Switch, 2 + 2
Answers from our engineering team on installation, compatibility and integration.
01What contacts does the EUCHNER NZ1VZ-3131E-M provide?
It provides a 3131 slow-action element with two positively driven contacts and two normally open contacts in one metal head.
02Is the EUCHNER NZ1VZ-3131E-M supplied with an actuator?
No. The actuator is ordered separately, for instance ACTUATOR-Z-G with 4 mm overtravel or ACTUATOR-Z-GN with 16 mm overtravel.
03What is the electrical rating of the NZ1VZ-3131E-M?
It is rated AC-15 4 A at 230 V and DC-13 4 A at 24 V, with a thermal current of 4 A and a fuse of up to 4 A gG.
04How is the NZ1VZ-3131E-M different from the NZ1VZ-2131E-M?
The 3131 version has two positively driven plus two normally open contacts, while the 2131 version has three positively driven plus one normally open contact.
05What environmental data applies to the NZ1VZ-3131E-M?
The anodized die-cast housing is IP67 and the switch operates and can be stored from minus 25 to plus 80 degrees C.