- Automation & ControlView all 3,128 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: EUCHNER
EUCHNER TZ1LE024M Guard Locking Safety Switch, 24 V
Description
Overview
When a machine guard has to stay shut until a hazardous movement has stopped, a guard locking switch is the component that holds the door and reports its state to the safety circuit. The EUCHNER TZ1LE024M is a TZ series safety switch with a spring-operated lock, a cable entry of M20 x 1.5, an auxiliary release on the front and the actuating head fitted on the left. It carries two positively driven contacts and two normally open contacts, split evenly between door monitoring and lock monitoring. Seven Star LLC is an independent supplier serving Oman and the GCC.
What the EUCHNER TZ1LE024M does in a safety circuit
The TZ works on the closed-circuit current principle, often called power to unlock. A spring pushes the locking bolt into the actuator whenever the solenoid has no power, so the guard stays locked even if the supply is lost. The solenoid must be energised to release the bolt, with a rated voltage of 24 V AC or DC, minus 15 percent to plus 10 percent, and a duty cycle of 100 percent. This makes the switch well suited to machines with run-down times, such as centrifuges, mixers, saws and presses, where an unexpected power failure must not release a door while parts are still moving.
Contacts and ratings of EUCHNER TZ1LE024M
| Characteristic | Data from the product page |
|---|---|
| Door monitoring contacts (SK) | Type 528: 1 positively driven contact plus 1 NO contact, slow-action |
| Lock monitoring contacts (UK) | Type 528: 1 positively driven contact plus 1 NO contact, slow-action |
| Guard locking principle | Closed-circuit current, locked by spring force |
| Solenoid voltage | 24 V AC/DC, minus 15 to plus 10 percent, 100 percent duty |
| Power consumption | 10 W |
| Utilisation categories | AC-15 4 A at 230 V; DC-13 4 A at 24 V (2 A above 70 degrees C) |
| Fuse | Maximum 4 A gG, 2 A gG above 70 degrees C |
| Rated insulation / impulse voltage | 250 V / 2.5 kV |
| Minimum switching load | 12 V at 10 mA; 1 mA at 24 V |
| Locking force | Fmax 2000 N; Fzh 1500 N |
| Actuating / extraction / retention force | 35 N / 30 N / 10 N |
| Approach speed | Maximum 20 m/min |
| Actuation frequency | Maximum 1200 per hour |
| Insertion depth | 52 mm |
| Cable entry | 1 x M20 x 1.5, wire cross section 0.34 to 1.5 mm2 |
| Housing and contacts | Anodised die-cast alloy; silver alloy, gold flashed |
| Protection / temperature | IP67; minus 25 to plus 80 degrees C |
| Mechanical life | 1 million operations |
How EUCHNER TZ1LE024M differs from other TZ variants
The letters in the code carry the differences. The L in LE means the head is fitted on the left; the matching TZ1RE024M has it on the right and otherwise identical ratings. The 1 selects a straight actuator entry in the TZ1 range, while TZ2 versions change the approach arrangement. The 024 states the 24 V solenoid, where 110 and 220 codes exist for mains voltages, and M states a cable gland instead of the M23, M26 or BHA connectors offered on other codes. Compared with the TZ1LE024MVAB, which uses 2131 and 3131 contact blocks, this switch has the smaller 528 contacts: one positively driven plus one NO per function.
Application notes for Oman and the GCC
Guard locking switches of this construction protect machine tools, packaging lines, bottling equipment, plastics and rubber machinery, woodworking saws and process mixers. In Oman and neighbouring countries they are specified by OEMs and maintenance teams of industrial estates and by engineering contractors upgrading older machines to current guard standards. The IP67 body and the temperature range up to 80 degrees C suit dusty halls and hot enclosures alike.
Installation and commissioning
Mount the switch on the fixed part of the frame and the actuator on the moving door so that the bolt enters the head in the intended direction, then check alignment before tightening, since the operating instructions allow only limited tolerance. Cable connection is made to terminals under the lid, using the M20 gland. Test the auxiliary release for correct operation and protect it against misuse, as the instructions require, by sealing or lacquer. Wire the solenoid to a controller which drives it only when the hazard has ended, and check the LED indicators, one red and one green, which can be assigned freely.
Service and inspection
Inspect the actuator and head for wear, loose screws and contamination at regular intervals. Check the correct function of the auxiliary release and the monitoring contacts during every safety inspection of the machine, and replace the unit when the stated mechanical life is reached. Do not repair or modify the switch. The B10d value for guard position monitoring is 3 million operations, with a mission time of 20 years, and the instructions describe the formulas for the performance level.
Actuator and ordering notes
The actuator is not included, so a TZ bolt must be ordered with the switch. State the full EUCHNER TZ1LE024M in your enquiry together with the actuator type and the supply voltage of your control circuit.
Choosing guard locking for a hazard with run-down time
Standards for interlocking devices ask designers to decide whether a guard may open immediately or only after the hazard has gone. If the machine stops quickly, a switch without locking can be enough. If spindles, blades or rotors keep turning for seconds, the guard must stay locked until the movement is finished, and the lock itself must be monitored. This is where the EUCHNER TZ1LE024M fits: the solenoid is released by the controller after a stop-time relay or standstill monitor confirms safe conditions, and the lock monitoring contact tells the safety circuit that the bolt is really in the locked position. Because the lock holds without power, a blackout cannot expose an operator to a coasting tool. If personnel must be able to leave a danger zone, the escape release variants of the series should be considered instead.
Related items you may also need: EUCHNER ZSM2100 Three-Position Enabling Switch | EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V | EUCHNER STP-TW-3A-2131AC024M Twin Guard Locking Switch | All EUCHNER products.
Documents and quotation
The operating instructions for the TZ series are attached to this page and describe mounting, wiring and the safety data. Please send your RFQ with EUCHNER TZ1LE024M, the quantity and your delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet EUCHNER TZ1LE024M Guard Locking Safety Switch, 24 V Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER TZ1LE024M Guard Locking Safety Switch, 24 V
Answers from our engineering team on installation, compatibility and integration.
01What is the solenoid voltage of the EUCHNER TZ1LE024M?
The solenoid is rated 24 V AC or DC, with a tolerance of minus 15 to plus 10 percent and a duty cycle of 100 percent.
02Is the TZ1LE024M power-to-unlock or power-to-lock?
It uses the closed-circuit current principle: a spring holds the guard locked and the solenoid must be energised to unlock it.
03What contacts does the TZ1LE024M provide?
Door monitoring has 1 positively driven contact plus 1 NO contact, and guard lock monitoring has the same combination, all slow-action.
04What locking force can the TZ1LE024M hold?
The product page lists a maximum locking force Fmax of 2000 N and a holding force Fzh of 1500 N.
05Does the TZ1LE024M include the actuator?
No. The actuator, called a bolt for series TZ, is a separate item and must be ordered together with the switch.


















Reviews
There are no reviews yet.