- Automation & ControlView all 3,053 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Metrohm
Metrohm 912 Conductometer Portable Conductivity Meter
Description
Overview
The Metrohm 912 Conductometer is a battery-powered conductivity meter for people who measure water and process liquids away from a bench as often as on one. It reads conductivity, total dissolved solids, salinity and temperature from a single analog input, and it is housed in a plastic case certified to IP67. Seven Star LLC is an independent supplier serving Oman and the GCC. The article number covered on this page is 2.912.0010, the basic instrument; Metrohm also lists kits with a sensor and carrying case and a laboratory version with stand plate, which are described below.
Measuring performance of the Metrohm 912 Conductometer
At the heart of the meter is a measuring input that Metrohm develops and produces in Switzerland. It covers conductance from 0.1 microsiemens up to 500 millisiemens, which means one instrument can follow ultrapure rinse water at the low end and brine or seawater at the high end. Resolution is four significant digits. Accuracy is stated as plus or minus 0.5 percent from 0.1 to 16 microsiemens and again from 16 microsiemens to 1 millisiemens, then plus or minus 1.0 percent from 1 to 500 millisiemens. Two-wire and four-wire sensors are supported so that the entire range can be covered with a suitable cell, and results can be shown in whichever unit the method calls for, including conductivity, TDS and salinity.
Specification table for Metrohm 912 Conductometer
| Item | Value |
|---|---|
| Measuring inputs | 1, analog, for conductivity / TDS / salinity / temperature |
| Conductance range | 0.1 microsiemens to 500 mS |
| Resolution | 4 significant digits |
| Accuracy | plus or minus 0.5 percent at 0.1 to 16 microsiemens; plus or minus 0.5 percent at 16 microsiemens to 1 mS; plus or minus 1.0 percent at 1 to 500 mS |
| Display | 3.5 inch colour display with backlight |
| Memory | 10,000 measured values |
| Power supply | rechargeable lithium-polymer battery, 3.7 V, 3,000 mAh |
| Protection class | IP67, tested for submersion up to 30 minutes |
| Dimensions W/H/D | 208 / 92 / 34 mm |
| Weight | 400 g |
| GLP data | user ID, timestamp and electrode ID stored with results |
| Interface | USB for export to PC or printer |
| Operating levels | user mode and expert mode, PIN protected |
Built for the field and the lab
The brochure for the 912, 913 and 914 family stresses three working situations. Outdoors, the battery gives all-day power and can be topped up from a car socket or an external power bank; notes such as location and sample name can be stored with each measurement. In a process plant, the meter checks key parameters in situ and the results are processed later in the laboratory. On the bench, a stand plate with support rod turns it into a benchtop instrument so that results can be printed immediately. The casing is made of a robust plastic that survives drops from elevation, and a compact carrying case holds the meter with all accessories.
Documentation and data security
Results are saved with date, time, sample identification and user name for documentation that fits good laboratory practice. Two user levels with password protection keep stored values from being altered, and the expert mode guards parameters against accidental changes by routine users. The meter recognises a stable measurement signal on its own, which removes operator judgement from the moment a reading is taken. A sensor pool manages the connected cells and lets the lab define its own acceptance criteria for calibrations. Data go to a PC as CSV or in PC/LIMS format over USB, and reports can be printed on dot matrix, thermal or A4 printers.
Article numbers and how 912 Conductometer differs from the 914
Three articles are listed for this meter: 2.912.0010 is the instrument alone, 2.912.0110 adds a conductivity sensor in a carrying case with accessories, and 2.912.0210 is the laboratory version with stand plate. The 912 has one analog input for conductivity only. The 914 pH/Conductometer adds a second galvanically separated analog input so that pH and conductivity can be measured simultaneously in the same sample, and its pH range of minus 13 to plus 20 with 0.001 resolution is not available on the 912. Choose the 912 when conductivity is the only parameter, and the 914 when pH is needed as well.
Where conductivity meters earn their keep in Oman
Desalination plants, cooling-water systems, boiler feedwater, wastewater treatment works and agricultural irrigation all depend on quick conductivity checks. A sudden rise in conductivity in a reverse osmosis permeate points to a damaged membrane; a drift in cooling tower water signals that blowdown is overdue; a high figure in irrigation water warns of salt damage to crops. With IP67 protection and a battery pack, the 912 can go from one sampling point to the next in summer heat without a mains outlet or a protective case.
Choosing sensors for the 912
Because the input accepts two-wire and four-wire cells, the choice of sensor depends on the sample. Low-conductivity water such as boiler feed and rinse water needs a cell with a small cell constant and short cabling, while saline samples and process brines work better with a four-wire cell that eliminates polarization and cable resistance errors at high conductance. The brochure notes that almost any Metrohm sensor can be connected, so existing cells in your laboratory remain usable, and the kit article with the sensor and carrying case is a convenient starting point for a new field programme.
Using the meter correctly
Select a cell constant that suits the expected range, calibrate with a traceable standard near the working value, and rinse the cell between samples so carry-over does not distort the next figure. Pay attention to temperature, because conductivity changes with temperature; the meter measures it with the sensor and applies compensation according to the method selected. Charge the battery fully before a long field day and download stored values regularly.
Related items you may also need: Metrohm 2035 Process Analyzer | Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 905 Titrando Potentiometric Titrator | All Metrohm products.
Points to confirm for the Metrohm 912 Conductometer
- If the Metrohm 912 Conductometer is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Metrohm 912 Conductometer request we confirm the exact code and lead time in writing.
- Dimensions, ratings and connection data for the Metrohm 912 Conductometer are in the datasheet attached to this page.
- The Metrohm 912 Conductometer belongs to our portable water quality meters range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Metrohm 912 Conductometer on critical service often hold a spare unit in the store.
Documents and quotation
The Metrohm brochure for the 912, 913 and 914 handheld meters is attached to this page and includes the ordering list for sensors, carrying case and printers. Send your RFQ with the model name, the article number, quantity, the type of sensor you need and your delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Metrohm 912 Conductometer Portable Conductivity Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.
Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.
Metrohm company profile
| Founded | 1943, Herisau, Switzerland |
|---|---|
| Founder | Bertold Suhner |
| Headquarters | Herisau, Switzerland |
| Ownership | Metrohm Foundation |
| Product families | Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes |
Metrohm instruments listed here
The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.
Metrohm products we list
| Family | Examples |
|---|---|
| Liquid Analytical Systems | 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr… |
Ordering Metrohm equipment: what we need
Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.
Facts checked against Metrohm's published company history, October 2026.
Browse Metrohm products by category: Liquid Analytical Systems.
FAQ
Questions about the Metrohm 912 Conductometer Portable Conductivity
Answers from our engineering team on installation, compatibility and integration.
01What conductivity range does the Metrohm 912 Conductometer cover?
The product page gives the conductance range as 0.1 microsiemens up to 500 mS with four significant digits of resolution.
02Is the Metrohm 912 Conductometer waterproof?
The housing is rated IP67, and the brochure states that even complete submersion for up to 30 minutes cannot cause damage.
03Which article numbers exist for the 912 Conductometer?
The brochure lists 2.912.0010 for the meter alone, 2.912.0110 with conductivity sensor and carrying case, and 2.912.0210 for the laboratory version with stand plate.
04How many results can the 912 Conductometer store?
It has an internal memory of 10,000 measured values, stored with user ID, timestamp and electrode ID for GLP-compliant records.
05Does the 912 measure pH as well?
No. It has one analog conductivity input; the 914 pH/Conductometer adds a second input so pH and conductivity can be measured together.


















Reviews
There are no reviews yet.