- Automation & ControlView all 2,240 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Industrial Computers
- Servo Drives
- Machine Vision
- Automation Software
- Robotics
Brand: Elster
Elster enCore FC1 Flow Computer – Honeywell Oil & Gas
Description
Overview
The Elster enCore FC1 is a high performance flow computer for oil and gas measurement applications, designed for gas and liquid measurement duties and the corresponding calculation algorithms. The name enCore, meaning Honeywell Elster new Core, refers to the backbone of the FC1 which carries the basic functionalities. A modular software system made of independent application function blocks (AFBs) turns the FC1 into a reliable, secure and high performance flow computer, and the same modularity in hardware means the widest range of applications can be covered.
The FC1 supports liquid measurement, PID control, turbine lubrication monitoring and soft PLC functions as application modules, widening its use from gas metering to station control. The enCore FC1 is a field-proven platform with a large installed base in gas metering stations
Engineering and Design
The enCore FC1 implements the widest range of calculation algorithms pursuant to AGA, ISO and API standards to fulfil all requested flow conversion requirements on natural gas and liquid streams. Multi-stream functionality and advanced logging properties are available, and the user-definable logging feature can use any desired amount of flash memory, so there are no restrictions in logging depth. By using cryptographic mechanisms, the unit can be securely updated and upgraded, even in a fiscal way.
Two housing sizes are offered: a one-third design width of 19 inches and a one-half design width of 19 inches, which differ in the number of I/O and communications boards (4 board slots versus 7 board slots). Input boards with integrated Ex-barriers allow small stations to be equipped with a high-end flow computer. The MFE7 input board provides seven multifunctional inputs (PT100, 4-20 mA or HART, digital pulse and status, and an RS485 channel), while the MFA8 output board provides digital and 0/4-20 mA analogue outputs. Predesigned device drivers connect analyzers, ultrasonic meters and transmitters, and the PC software offers Normal mode and Expert mode configuration.
The FC1 supports liquid measurement, PID control, turbine lubrication monitoring and soft PLC functions as application modules, widening its use from gas metering to station control. With its predesigned device drivers the FC1 connects to analyzers, ultrasonic meters and transmitters directly, and the service interface allows secure remote access for configuration and diagnostic work. The FC1 hardware can be ordered with integrated Ex barriers for small stations, reducing cabinet complexity, and the USB front panel port gives service engineers a fast configuration path at the site without opening the cabinet.
Key Features
- Multi-stream oil and gas flow computer
- Calculation algorithms per AGA, ISO, API and GPA
- Modular hardware: 4 or 7 board slot versions
- Cryptographically secure field upgrades
- User-definable flash logging depth
- Integrated Ex-barrier I/O board option
- Predesigned drivers for analyzers and ultrasonic meters
Applications
The enCore FC1 is used in natural gas transmission and distribution stations, custody transfer and fiscal metering, gas and liquid measurement applications, pipeline station automation, and remote metering stations where secure data logging, multiple user levels and audit trails are required.
Specifications
| Type | modular oil and gas flow computer |
| Calculations | AGA, ISO, API, GPA |
| Housing | 1/3 or 1/2 of 19 inch width (4 or 7 board slots) |
| Communications | Ethernet (HTTP/MMS/Modbus/NTP), serial channels, USB front panel |
| Input board (MFE7) | 7 multifunctional inputs: PT100, 4-20 mA/HART, pulse/status, RS485 |
| Output board (MFA8) | 8 multifunctional outputs, 0/4-20 mA analogue |
| Ex | optionally integrated intrinsic safety barriers |
| Power | 24 V DC ±20% (typ. 5 W, max. 12 W) |
| Software | Normal mode and Expert mode configuration |
| Housing size | 19 in design, 3U height, 1/3 or 1/2 width, 170 mm depth |
| Display | 4.3 in full-colour wide screen (480 × 272 px), LED backlight, touch screen |
| Power consumption | Typ. 5 W, max. 12 W |
| Operating temperature | -20 to +50 °C |
| Input board (ExMFE5) | 5 multifunctional inputs (Ex version) |
| Communication board (ESER4) | 3 serial channels, 1 Ethernet port |
| Serial protocols | Modbus (ASCII, RTU), Uniform, Encoder, Printer |
| Archive capacity | Flexible, up to 900 values per archive |
| Standards and approvals | MID, PTB, API Chapter 21, OIML R117 |
Hardware Platform and Display
Honeywell describes the enCore FC1 as a 19 in design, 3U high, available in 1/3 or 1/2 width with a depth of 170 mm. The front carries a 4.3 in full-colour wide screen (480 × 272 px) with LED backlight and touch screen. The unit is powered from 24 V DC ±20%, with a typical consumption of 5 W and a maximum of 12 W, and the specified ambient temperature range is -20 to +50 °C.
The input and output boards are selected per application. ExMFE5 provides five multifunctional inputs with integrated Ex protection, MFE7 provides seven (PT100, 4-20 mA/HART, digital and RS485), and MFA8 provides eight multifunctional outputs (LF/status digital and 0/4 to 20 mA analogue). The ESER4 communication board offers three serial channels and one Ethernet port. Ethernet protocols are MMS, Modbus and NTP; serial protocols include Modbus (ASCII, RTU), Uniform, Encoder and Printer.
Why Seven Star LLC
Seven Star LLC supplies the Honeywell Elster enCore FC1 flow computer for gas metering stations in Oman and the GCC, including configuration support, I/O board selection and spare parts.
Request a Quote for Elster enCore FC1 Flow Computer – Honeywell Oil & Gas
Contact Seven Star LLC for the Elster enCore FC1 flow computer for your metering station | Inquiry Form
Related Products
- OMNI 4000/7000 Series
- Elster® enCore ZM1 Flow Computers
- ABB Flow-X/M modules Flowcomputer
- KROHNE SUMMIT 8800 Flow Computer
- NI cRIO-9053 CompactRIO Real-Time Controller
- OMNI 6000 Flow Computer with Operator Display
Where the Elster enCore FC1 is used
- Gas metering stations
- Liquid measurement stations
- Multi-stream measurement skids
- Station control
- Turbine lubrication monitoring
Selection checklist for the Elster enCore FC1
- Gas or liquid duty
- Number of streams
- Housing width
- Number of board slots
- Input signal types
- Output needs
- Connected analyzers and meters
- Logging depth
Installation, commissioning and maintenance notes for the Elster enCore FC1
Mount the flow computer in the panel and fit the input and output boards. Connect the meters, the transmitters and the analyzers and load the configuration. Check the inputs and the logs at regular intervals.
Requesting a quotation for the Elster enCore FC1
Please send the streams, the meter types and the signals. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
Elster enCore FC1 device type
It is a flow computer for oil and gas measurement.
Elster enCore FC1 maker
It is made by Honeywell Elster.
Elster enCore FC1 name
The name enCore means the Honeywell Elster new Core.
Elster enCore FC1 backbone
The core of the FC1 carries the basic functions.
Elster enCore FC1 software
The software is modular and made of independent application function blocks.
Elster enCore FC1 hardware
The hardware is modular too, so many applications can be covered.
Elster enCore FC1 duties
It handles gas and liquid measurement duties.
Elster enCore FC1 PID control
PID control is available as an application module.
Elster enCore FC1 soft PLC
Soft PLC functions are available as application modules.
Elster enCore FC1 installed base
It is a field-proven platform with a large installed base in gas metering stations.
Elster enCore FC1 multi-stream
Multi-stream functions are available.
Elster enCore FC1 logging
User-definable logging can use any amount of flash memory.
Elster enCore FC1 logging depth
There is no restriction on logging depth.
Elster enCore FC1 updates
Cryptographic mechanisms allow secure updates and upgrades.
Elster enCore FC1 housing sizes
Two housing sizes are offered, one-third and one-half of a 19 inch design width.
Elster enCore FC1 slots
The smaller housing has 4 board slots and the larger one has 7.
Elster enCore FC1 input board
The MFE7 input board provides seven multifunctional inputs.
Elster enCore FC1 input types
The inputs cover PT100, 4-20 mA or HART, digital pulse and status, and an RS485 channel.
Elster enCore FC1 output board
The MFA8 output board provides digital and 0/4-20 mA analogue outputs.
Elster enCore FC1 drivers
Predesigned device drivers connect analyzers, ultrasonic meters and transmitters.
Elster enCore FC1 PC software
The PC software offers Normal mode and Expert mode configuration.
Elster enCore FC1 small stations
Small stations can be fitted with a high-end flow computer.
Elster enCore FC1 support
Seven Star LLC gives local technical support with selection.
Station records for the Elster enCore FC1
Record the configuration, the board layout and the date of each check.
Choosing the right Elster enCore FC1 housing
Choose the housing from the number of inputs, outputs and communications boards the station needs.
See also: Elster EK280 Gas Volume Conversion Device.
Datasheets & Documents
- Datasheet Elster enCore FC1 Flow Computer – Honeywell Oil & Gas Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Elster is a gas metering and combustion control brand founded on 1 October 1848 in Berlin, where it began by making gas lamps. It built a factory in Mainz in 1876 and later merged with the Dutch flow specialist Instromet in 2005. Melrose bought the Elster group in 2012, and Honeywell acquired it in 2015–2016, so Elster products are now sold by Honeywell.
Seven Star LLC sources and supplies Elster ultrasonic flow meters, gas flow computers and station communication units for pipeline and utility operators in Oman.
Elster company profile
Founded1 October 1848, Berlin, GermanyHeadquartersMainz-Kastel, Germany (historic group base)OwnershipHoneywell, since the end of 2015 / January 2016Related brandsInstromet, Kromschröder and American Meter, all part of the former Elster groupProduct familiesTurbine, rotary and ultrasonic gas meters, volume correctors and flow computers, gas pressure regulators and safety shut-off valves, Kromschröder burner controls and valves
Milestones
1848: Elster is founded in Berlin and starts producing gas lamps.1876: The factory in Mainz is built.2005: Elster and Instromet merge.2012: Melrose acquires the Elster group.2016: Honeywell completes its purchase of Elster from Melrose.
Elster product families listed here
The Elster flow meter on this page is the Q.Sonic plus, a multipath ultrasonic gas meter for custody transfer measurement, listed together with a USM display unit. Flow computers come from two device series. The enCore series is represented by the enCore FC1 and the enCore ZM1. The gas-net series is represented by the gas-net F1 flow computer and the gas-net D2, a data forwarding unit for the DSfG station interface used in German-standard gas metering systems.
Where Elster gas metering equipment is used
Elster gas meters and flow computers work at transmission and distribution metering stations, city gate and pressure reduction stations, power plant and industrial fuel gas inlets, and gas storage sites. The flow computer converts measured volume to base conditions using pressure, temperature and gas quality data, records the fiscal archives and passes data to the SCADA system.
Elster products we list
FamilyExamplesFlowmetersIRM-3 DUO Rotary Gas Meter DN100 to DN200, Q.Sonic plus Ultrasonic Gas Flow Meter, Quantometer Q/Q75 Turbine Gas Meter DN50…, RABO Rotary Gas Meter DN32 to DN150, TRZ2 Turbine Gas Meter DN50 to DN150, Honeywell Elster USM QP Ultrasonic Flow…Flow ComputersEK280 Gas Volume Conversion Device, enCore FC1 Flow Computer, gas-net F1 Flow Computer for Gas Measure…, Elster® enCore ZM1 Flow ComputersIndustrial CommunicationsGas-Net D2 DSfG-DFU Data Forwarding UnitGas Analyzer SystemsGasLab Q2 Real-Time Natural Gas Quality…
Ordering Elster meters and flow computers: what we need
For an ultrasonic meter: nominal size, pressure rating and flange standard, flow range, gas composition, operating pressure and temperature, the metrological approval required and the flow calibration expected. For a flow computer: device type, the serial number and software version of the existing unit, the I/O boards fitted, the meters and transmitters connected, the conversion and compressibility method (for example AGA 8) and the communication protocols. A photo of the type plate and the parameter printout shorten the check against the manufacturer's documentation considerably.
Facts checked against Elster's own milestone timeline and the Honeywell acquisition announcements, October 2026.
Browse Elster products by category: Flow Computers, Flowmeters, Industrial Communications.
FAQ
Questions about the Elster enCore FC1 Flow Computer
Answers from our engineering team on installation, compatibility and integration.
01What is the Elster enCore FC1?
The enCore FC1 is a modular oil and gas flow computer designed for gas and liquid measurement applications. It is built on the Honeywell Elster 'new Core' platform with independent application function blocks for reliable and secure flow computing.
02Which calculation standards does the FC1 support?
The FC1 implements the widest range of calculation algorithms pursuant to AGA, ISO, API and GPA standards to fulfil all required flow conversion requirements for natural gas and liquid measurement.
03Can the FC1 be updated in the field?
Yes. The FC1 can be securely updated and upgraded using cryptographic mechanisms, including in a fiscal way, via USB or TCP/IP with partial software upgrades.
04What I/O options are available?
The modular hardware accepts MFE7 input boards with PT100, 4-20 mA/HART (seven multifunctional inputs in total), pulse/status and RS485 channels, and MFA8 output boards with eight multifunctional outputs, with integrated Ex-barriers available for small stations.
05What communications are supported?
The FC1 provides Ethernet with HTTP, MMS, Modbus and NTP protocols, serial channels, a USB front panel interface, and predesigned device drivers for analyzers, ultrasonic meters and transmitters.


















Reviews