AMETEK 700-0001-022 Drexelbrook 3/8 in PTFE Level Probe
Description
AMETEK 700-0001-022 overview
AMETEK 700-0001-022 is the plain, no-frills rod in the Drexelbrook range of RF level sensing elements: a 3/8 inch outside diameter rod covered in PTFE, intended for general purpose service in non-coating conductive liquids of low viscosity. In the manufacturer selection table it is the first entry, which tells you how often it is the default answer when a tank holds clean water, a dilute aqueous solution or a similar well-behaved conductive process fluid. 700-0001-022 carries the three-digit sensing element code 301 in the Universal IV model number, and the same rod appears as code 301 in the Z-tron IV point level switch family.
A probe like 700-0001-022 does one thing: it forms one plate of a capacitor whose other plate is the vessel wall or the process liquid itself. As the liquid rises along the PTFE covered rod the electrical admittance seen by the electronics changes, and the Drexelbrook electronics turn that change into a 4-20 mA signal or a relay trip. The probe has no moving parts, which is the reason maintenance planners in refineries and water plants like it as a spare to stock.
Key features of 700-0001-022
- 3/8 inch OD rod with PTFE cover, giving a chemically inert wetted surface.
- Rated 1000 psi up to 100 F and 500 psi up to 300 F, according to the manufacturer table.
- Targeted at non-coating conductive liquids with low viscosity; for heavy coating the manufacturer points to other sensing elements.
- Shared across RF families: the datasheet states that all 700-xxxx-xxx probes are common across Drexelbrook RF products, so the rod can stay in the tank when the electronics are upgraded.
- Listed under SE code 301 so it can be specified inside a Universal IV model number.
Technical specifications for 700-0001-022
| Parameter | Value |
|---|---|
| Part number | 700-0001-022 |
| Sensing element type | RF admittance / capacitance rod probe |
| Construction | 3/8 inch OD PTFE covered rod |
| Typical application | General purpose, non-coating conductive liquids, low viscosity |
| Maximum pressure at 100 F | 1000 psi |
| Maximum pressure at 300 F | 500 psi |
| Maximum temperature in table | 300 F |
| Universal IV SE code | 301 |
| Z-tron IV element code | 301, 316 SS and TFE wetted parts |
| Compatible electronics | Universal IV, Universal III, Universal Lite, RCT, Z-tron IV |
| Universal IV supply | 13 to 30 VDC, 2-wire loop powered, 4-20 mA with HART |
| Universal IV accuracy | 0.25 percent of span (ranges 2 to 6) |
| Remote cable limit | 100 ft maximum for remote configuration |
The values below come from the Drexelbrook Universal IV selection table and the Z-tron IV sensing element table. Insertion length, process connection and mounting style are chosen at order time and are not part of the fixed part number.
Where 700-0001-022 is used in Oman and the GCC
Clean conductive liquids are everywhere in the Gulf: desalinated and potable water storage, cooling water make-up tanks at power stations, chemical dosing day tanks, and condensate collection in gas processing plants. A PTFE covered rod suits these services because the wetted surface does not corrode and does not support scale as readily as bare metal. Operators of utilities in Oman often hold 700-0001-022 as a swap-in spare because a damaged PTFE cover after years of chemical exposure is a typical failure that does not justify replacing the whole transmitter.
How 700-0001-022 differs from other Drexelbrook probes
Compared with its neighbours in the table, 700-0001-022 is the simplest geometry. The 700-0002-024 is a thicker 3/4 inch PTFE rod that reaches 450 F at 500 psi. The 700-0002-037 is a 1/2 inch PVDF rod meant for heavier coating liquids and interface work, limited to 250 F. The 700-0001-026 uses the same 3/8 inch PTFE rod but adds a 1.66 inch perforated carbon steel concentric shield to give a non-linear ground reference in insulating liquids. The 700-0005-018 is a flexible 5/16 inch PVDF cable. If your liquid is conductive and clean and the vessel is metal, 700-0001-022 is the rod to start with; if the liquid coats, look away from it.
Selection and compatibility notes
Check three things before ordering 700-0001-022. First, the liquid must be conductive and non-coating; the manufacturer positions the rod specifically for that case. Second, temperature and pressure must sit inside the stated envelope: 1000 psi at 100 F falling to 500 psi at 300 F. Third, the electronics must be of a compatible Drexelbrook family. The datasheet confirms backward compatibility of probes across Universal IV, Universal III, Universal Lite and RCT systems, and the Z-tron IV switch also accepts this element.
Installation and commissioning of 700-0001-022
Mount the rod so that it hangs clear of tank walls, internal ladders and agitators; the PTFE cover is tough but it is not a structural member. Use the process connection ordered with the probe, avoid over-torquing NPT threads, and keep the electronics housing supported when the sensor is long. At commissioning set the empty and full capacitance points using the keypad and LCD on the Universal IV, or the HRTWIN software; the manufacturer quotes a start-up time under 12 seconds, so the signal is available almost at once after power-up.
Maintenance and spare planning for 700-0001-022
There is nothing to calibrate on the rod itself. Inspect the PTFE cover during shutdowns for cuts or swelling, wipe the process end clean, and confirm that the connector or seal at the head is dry. A spare 700-0001-022 on the shelf reduces downtime because the electronics and configuration stay untouched. Record the SE code 301 and the insertion length on the asset tag so that a replacement can be matched without opening the vessel documentation.
Related products and ordering notes
Related sensing elements in the same selection table include 700-0001-026, 700-0001-344, 700-0002-024 and 700-0005-018. When requesting a quotation for 700-0001-022 give the insertion length, process connection and the electronics model it will pair with. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Frequently asked questions about 700-0001-022
The questions below cover the points buyers raise most often about 700-0001-022: suitable liquids, pressure and temperature limits, how it differs from shielded or PVDF rods, and electronics compatibility. Detailed answers are in the FAQ block of this page.
Documents and quotation
The Drexelbrook Universal IV Pro and Lite datasheet is attached to this page and contains the probe selection table used for 700-0001-022. To receive a quotation, send an RFQ with part number 700-0001-022, the quantity, required insertion length and process connection, and we will respond with availability and lead time.
Datasheets & Documents
- Datasheet AMETEK 700-0001-022 Drexelbrook 3/8 in PTFE Level Probe Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK 700-0001-022 Drexelbrook 3/8 in PTFE Level
Answers from our engineering team on installation, compatibility and integration.
01What liquids is 700-0001-022 intended for?
The manufacturer table lists 700-0001-022 for general purpose, non-coating conductive liquids of low viscosity, such as clean aqueous solutions.
02What pressure and temperature limits apply to 700-0001-022?
The Universal IV table gives 1000 psi up to 100 F and 500 psi up to 300 F for this 3/8 inch PTFE covered rod.
03Can 700-0001-022 be used with Universal III electronics?
Yes. The datasheet states all 700-xxxx-xxx probes are common across Drexelbrook RF products, including Universal III, Lite and RCT.
04How is 700-0001-022 different from 700-0001-026?
Both use a 3/8 inch PTFE rod, but 026 adds a 1.66 inch perforated carbon steel concentric shield for insulating liquids; 700-0001-022 has no shield and suits conductive liquids.
05What should I send with an RFQ for 700-0001-022?
Send the part number 700-0001-022, quantity, insertion length, process connection and the electronics model so the correct assembly can be quoted.