Brand: Beamex
Beamex 8006130 ePG Piston Seal Service Kit
Description
Beamex 8006130 ePG piston seal service kit overview
The Beamex 8006130 is the piston seal service kit for the ePG electric pressure pump. It includes the piston seals, the piston guiding ring with its replacement tool, and the cylinder O-ring.
Beamex supports the service with an instructional video and with the Maintenance section of the ePG user manual, so the work can be done by the user rather than at the factory.
This page describes Beamex 8006130 for buyers who need the exact order code. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the ePG piston seal service kit
- Piston seals
- Piston guiding ring with replacement tool
- Cylinder O-ring
- Step-by-step video and manual instructions from Beamex
Standard delivery and contents according to Beamex:
- Piston seals
- Piston guiding ring
- Replacement tool for the guiding ring
- Cylinder O-ring
Technical specifications of Beamex 8006130
| Order code | 8006130 |
|---|---|
| Fits | Beamex ePG electric pressure pump and controller |
| Contents | Piston seals, piston guiding ring with replacement tool, cylinder O-ring |
| Instructions | ePG user manual (Maintenance section) and Beamex instructional video |
All values are taken from Beamex documentation. Items not shown here are not stated in the manufacturer source and are therefore left out.
Typical applications in Oman and the GCC
Hand pumps and electric pumps in calibration workshops wear over time because seals and O-rings are consumables. Maintenance teams in oil and gas, power, water and manufacturing sites across Oman and the GCC keep service kits such as the ePG piston seal service kit (8006130) so that a pump that has lost pressure holding ability can be restored without waiting for a replacement unit.
Buyers often search for the exact order code because the right kit depends on the model and on the generation of the pump. Quoting 8006130 with your request avoids mix-ups between similar pumps.
Selection and compatibility notes for 8006130
Select the kit by pump model first, then confirm the order code. Beamex lists separate kits for different pumps and sometimes for different generations of the same pump, so only 8006130 should be used with the pump named on this page.
Check the contents against the work you need to do. Some kits cover only part of a pump, while others are full service kits. If in doubt, read the maintenance section of the relevant Beamex manual before ordering.
Installation and commissioning
Depressurize the pump and disconnect all hoses before starting. Work on a clean surface, lay out the removed parts in order and compare them with the new parts. Use only the tools named in the Beamex documentation.
Lightly grease seals only where the manual says so, refit parts in the reverse order of removal and leak-test the pump at low pressure before returning it to service. Keep the manual for 8006130 at hand during the work.
Maintenance and care
Store unused kits in a clean dry place in their packaging. After servicing, record the date so the next service interval is easy to plan.
Do not mix old and new seals in the same assembly. Replace all parts the manual tells you to replace in one session.
Related products and ordering notes
Beamex lists these related items, each with its own order code:
- 9021115 ePG complete kit
- 8006145 ePG non-return valve kit
- 8006160 ePG mesh filters (5 pcs)
- 8006030 battery pack ePG
Beamex is a Finnish maker of calibration equipment, and its manuals and product pages are the reference for every figure on this page. Always check the manufacturer’s current documentation before putting any accessory or spare part into service.
Seven Star LLC works with industrial maintenance, procurement and calibration teams, so requests that include the full order code, the quantity and the delivery location can be answered quickly. Order codes are often the only reliable way to separate similar-looking accessories from different product generations.
Plants in the region usually plan calibration work around shutdowns, turnarounds and seasonal maintenance windows. Ordering accessories and spare parts well before the work starts avoids waiting for a missing seal, hose or cable when the plant is already offline, and it is cheaper than expediting a single item at the last minute.
Good calibration practice also depends on traceability. Records of the reference equipment, its certificate, the environmental conditions and the as-found and as-left results are what auditors and clients ask for. Accessories do not replace the calibration of the reference itself, but a worn hose, a leaking seal or a damaged cable can spoil an otherwise good measurement, which is why consumables should be replaced on a schedule rather than only after a failure.
When you compare quotations, make sure the order code is identical. Calibration accessories from the same manufacturer often differ only by thread, length or pressure rating, and a similar-looking item with a different code may not be compatible with your equipment. Keep the code on the purchase order, the goods receipt note and the maintenance record so that the same item can be reordered later.
Frequently asked questions about 8006130
What does 8006130 contain? The piston seals, the piston guiding ring with a replacement tool, and the cylinder O-ring.
Which pump uses this kit? The Beamex ePG electric pressure pump and controller.
Where are the instructions? In the Maintenance section of the ePG user manual, and in an instructional video that Beamex publishes.
Can the user do this service? Beamex states that the most common maintenance tasks can be carried out by the user without returning the pump.
When is it needed? When the piston seals show wear, for example if the pump no longer builds pressure as expected. Follow the manual for diagnosis.
Documents and quotation
The official Beamex ePG electric pressure pump user manual is attached to this page as a PDF. Its maintenance chapter references the piston seal service kit 8006130 (page 67) and the replacement procedure. Share order code 8006130 together with your calibrator model and we will confirm the exact part in a written quotation.
Quote Beamex 8006130 exactly as written when you contact us, so that the correct item is quoted the first time. Delivery to Oman and to other GCC countries is arranged for each order, and any questions about packaging, documentation or alternative items can be raised in the same message.
Datasheets & Documents
- Datasheet Beamex ePG User Manual (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8006130 ePG Piston Seal Service Kit
Answers from our engineering team on installation, compatibility and integration.
01What does 8006130 contain?
The piston seals, the piston guiding ring with a replacement tool, and the cylinder O-ring.
02Which pump uses this kit?
The Beamex ePG electric pressure pump and controller.
03Where are the instructions?
In the Maintenance section of the ePG user manual, and in an instructional video that Beamex publishes.
04Can the user do this service?
Beamex states that the most common maintenance tasks can be carried out by the user without returning the pump.
05When is it needed?
When the piston seals show wear, for example if the pump no longer builds pressure as expected. Follow the manual for diagnosis.