Brand: Moore Industries
Moore Industries SPA/HART/4PRG/U/-AO [DIN] HART Loop Monitor Alarm
Description
Moore Industries SPA/HART/4PRG/U/-AO [DIN] overview
The Moore Industries SPA/HART/4PRG/U/-AO [DIN] is the HART loop monitor and alarm version of the Moore Industries SPA family. It installs across the 4-20 mA loop of a smart transmitter or valve, reads the HART digital data on the same wires and operates up to four relay outputs, with an optional isolated analog output.
In the model string HART is the input type, 4PRG gives four independent relays, U selects the universal power supply, -AO adds the analog output and [DIN] is the rail-mount metal housing. The manufacturer describes it as the first site-programmable HART loop monitor and alarm and positions it as a transmitter and valve watchdog that works around the clock.
The SPA/HART/4PRG/U/-AO [DIN] is useful when process alarms and instrument health alarms are both needed, because the same unit can raise a relay for a process limit and another for a HART fault condition.
The part number written as SPA/HART/4PRG/U/-AO [DIN] is the model string given in the manufacturer datasheet as a worked ordering example for the SPA HART family, so it describes one complete, orderable configuration rather than a loose product family. Every field of the string (unit, input, output, supply or power, option and housing) can be changed when a different configuration is needed, and the datasheet table lists the allowed choices. If your plant standard differs from this example, send the configuration you need with your RFQ and we will check it against the table.
Key features of the Moore Industries SPA/HART/4PRG/U/-AO [DIN]
- Continuously monitors smart temperature, pressure, level and flow transmitters, multivariable transmitters and smart valve positioners.
- Up to four independent relay outputs for high or low limits or for instrument health conditions.
- Fault messages from the HART field device status byte, including primary variable out of limits, non-primary variable out of limits, primary variable analog output out of limits or fixed, cold start, device malfunction and more status available.
- Optional isolated analog output that can re-transmit the primary variable, break out a second, third or fourth variable, or track valve stem position.
- Self-diagnostics: the unit monitors its own status and can raise an alarm with a message on the LCD.
- On-site programming with a front-panel display and push buttons.
- Universal power input of 22-300 Vdc or 90-260 Vac; units with CE approval must be ordered with fixed power supplies according to the datasheet note.
Technical specifications for SPA/HART/4PRG/U/-AO [DIN]
| Parameter | Value |
|---|---|
| Model string | SPA/HART/4PRG/U/-AO [DIN] |
| Input | HART loop signal, connected in parallel across the 4-20 mA loop |
| Loop load for communication | Between 250 ohms and 1100 ohms |
| Alarm outputs | Up to four independently configurable relays; 4PRG gives four |
| Analog output option | -AO: isolated, linear 4-20 mA or 0-10 V |
| Power | U universal: 22-300 Vdc or 90-260 Vac (CE-approved units use fixed supplies of 24DC, 117AC or 230AC) |
| Monitored variables | Primary, second, third and fourth dynamic variables of the HART device |
| HART master role | Configured as secondary master when the control system is the primary master; as primary master when the control system is not HART-communicating |
| Housing | Metal, RFI-resistant housing that snaps onto standard rails |
| Certifications | CSA general location (NRTL/C); CE conformant, EMC Directive 89/336/EEC EN 61326 and Low Voltage Directive 73/23/EEC EN 61010 |
The values above come from the manufacturer datasheet for the SPA HART family. Specifications can depend on the option and housing chosen, so always read the matching page of the datasheet before you finalise a purchase specification, and keep the full model string on your purchase documents.
Typical applications in Oman and the GCC
Limit alarm trips are used wherever a process variable must start an independent warning or shutdown action without relying on the control system. In the region this typically means:
- Oil and gas loops with smart pressure, temperature, level and flow transmitters where a HART fault should trigger an independent alarm.
- Smart valve and positioner monitoring on emergency shutdown and control valves.
- Power and water utilities that use multivariable transmitters and need a second or third variable as a separate signal.
- Process and manufacturing plants that want diagnostic alarms without changing the control system.
The unit is passive on the HART link, so it can be added to an existing loop to gain diagnostic visibility without changing the control strategy.
Selection and compatibility notes
The SPA/HART/4PRG/U/-AO [DIN] must be connected where the loop has the load required for HART communication, 250 to 1100 ohms. It can be connected at any termination point in the signal loop. If the control system already acts as primary HART master, the SPA is set as secondary master, which means that a separate HART communicator cannot be used on that loop at the same time.
The datasheet also describes valve monitoring and partial stroke test support with a smart positioner. If you intend to use the unit that way, state the positioner type in your RFQ so we can check the application against the datasheet.
Questions to settle before ordering SPA/HART/4PRG/U/-AO [DIN]:
- Is the field device HART-capable and is the loop load between 250 and 1100 ohms?
- Which variables and fault conditions should drive which relay?
- Is the analog output required, and for which variable?
- Which supply voltage is available, and is CE marking a requirement?
- Is an enclosure needed for harsh locations?
Installation and commissioning
Connect the unit in parallel with the 4-20 mA loop, observe the polarity at the +IN and -IN terminals and verify the loop resistor value. The datasheet shows a 250 ohm resistor in the loop for communication.
Configure the HART operating parameters, the variables to be watched, each relay assignment and the optional analog output from the front panel. Verify each alarm with the field instrument by simulating the condition in the field device or with a calibrator.
Maintenance and service life
Periodically review the alarm history of your system against actual device faults. Check that the relay outputs still change state during functional tests and that the loop load stays in the required range after changes to the loop wiring.
Because the SPA monitors its own status, any internal fault can be wired to a relay so that the plant knows the watchdog itself is healthy.
Related products and ordering notes
The Moore Industries HIM smart HART loop interface and monitor and the HES HART to Ethernet gateway on this site address other HART needs. The base SPA alarm trip is offered for non-HART signals.
State the complete model string and the intended application when you request a price.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model designations belong to their owners and are used here only to identify the equipment you are asking about.
Frequently asked questions in brief
- What does the SPA/HART/4PRG/U/-AO [DIN] do? It reads HART data from a smart transmitter or valve on a 4-20 mA loop and operates up to four relays, with an optional analog output.
- What loop load does the SPA/HART/4PRG/U/-AO [DIN] need? The datasheet requires a load between 250 ohms and 1100 ohms for HART communication.
- Can the SPA/HART/4PRG/U/-AO [DIN] re-transmit another variable? Yes, the analog output option can send the primary variable or the second, third or fourth variable of the device.
- What power does the SPA/HART/4PRG/U/-AO [DIN] accept? The U option accepts 22-300 Vdc or 90-260 Vac; CE units require fixed supplies.
- How do I get a quotation for the SPA/HART/4PRG/U/-AO [DIN]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.
Documents and quotation
The manufacturer datasheet for the SPA HART family is available for download from this page, and it contains the full ordering table, dimensional drawings and wiring diagrams referred to above. To request a quotation, send an RFQ that includes the part number SPA/HART/4PRG/U/-AO [DIN], the quantity you need, the delivery location in Oman or the GCC and any special requirements such as certification or documentation. We will confirm availability and lead time and reply with a written offer. Please check the datasheet and your own hazardous-area and safety requirements before you place an order.
Datasheets & Documents
- Datasheet SPA HART Loop Monitor and Alarm Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the Moore Industries SPA/HART/4PRG/U/-AO [DIN] HART
Answers from our engineering team on installation, compatibility and integration.
01What does the {pn} do?
It reads HART data from a smart transmitter or valve on a 4-20 mA loop and operates up to four relays, with an optional analog output.
02What loop load does the {pn} need?
The datasheet requires a load between 250 ohms and 1100 ohms for HART communication.
03Can the {pn} re-transmit another variable?
Yes, the analog output option can send the primary variable or the second, third or fourth variable of the device.
04What power does the {pn} accept?
The U option accepts 22-300 Vdc or 90-260 Vac; CE units require fixed supplies.
05How do I get a quotation for the {pn}?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

















![Moore Industries SPA/HART/4PRG/U/-AO [DIN] HART Loop Monitor Alarm Moore Industries SPA/HART/4PRG/U/-AO [DIN] HART Loop Monitor Alarm](https://omansevenstar.com/wp-content/uploads/2026/11/moore-industries-spa-hart-4prg-u-ao-din-loop-monitor.webp)