Brand:

Pepperl+Fuchs KFD2-STC4-Ex1 SMART Transmitter Power Supply

Description

Pepperl+Fuchs KFD2-STC4-Ex1 overview

The Pepperl+Fuchs KFD2-STC4-Ex1 is a one-channel isolated barrier from the K-System of Pepperl+Fuchs that supplies SMART transmitters installed in a hazardous area. It powers both 2-wire and 3-wire transmitters, and it can also be used with 2-wire SMART current sources. The analog input signal is passed to the safe area as an isolated 0/4 to 20 mA current, and digital signals can be superimposed on that signal in either area and are carried in both directions, so HART communication reaches the transmitter.

The datasheet released on 22 July 2026 lists protocol support for HART, BRAIN and Foxboro. Test sockets for a handheld communicator are built into the terminals, and an internal 250 ohm resistor between terminals 8 and 9 is available when the loop resistance would otherwise be too low for communication. The housing is the 20 mm wide type B2, mounted on a 35 mm DIN rail, and the module can take its 24 V DC supply from the Power Rail or from terminals 14 and 15.

Key features of the Pepperl+Fuchs KFD2-STC4-Ex1

  • One-channel isolated barrier for intrinsic safety applications, with up to SIL 2 according to IEC/EN 61508
  • Supplies 2-wire and 3-wire SMART transmitters and accepts 2-wire SMART current sources
  • 0/4 to 20 mA output into loads from 0 to 800 ohm at 20 mA
  • Supports HART, BRAIN and Foxboro SMART protocols with bi-directional digital communication
  • Integrated test sockets for handheld communicators and a built-in 250 ohm resistor on terminals 8 and 9
  • Powered from 20 to 35 V DC through the Power Rail or terminals 14 and 15
  • Marking [Ex ia Ga] IIC, [Ex ia Da] IIIC and [Ex ia Ma] I; device itself marked Ex nA for Zone 2
  • Ambient temperature from minus 20 to 60 degrees C, IP20, removable screw terminals

KFD2-STC4-Ex1 technical specifications

The values below are taken from the manufacturer datasheet of the KFD2-STC4-Ex1, release date 2026-07-22. Always confirm the current datasheet and the certificates before final engineering.

Parameter Value
Model KFD2-STC4-Ex1, SMART Transmitter Power Supply, 1-channel isolated barrier
Signal type Analog input
Safety Integrity Level SIL 2
Rated supply voltage 20 to 35 V DC (Power Rail or terminals 14+, 15-)
Power dissipation / consumption 1.4 W / 1.8 W
Input 0/4 to 20 mA, terminals 1+, 2-, 3 or 5-, 6+
Voltage drop (terminals 5, 6) Up to 2.4 V at 20 mA
Available voltage (terminals 1+, 3) At least 16 V at 20 mA
Output 0/4 to 20 mA, terminals 7-, 8+, 9; load 0 to 800 ohm at 20 mA; overload above 25 mA
Deviation at 20 degrees C Up to 10 microamperes including calibration, linearity, hysteresis, load and supply fluctuation
Influence of ambient temperature 0.25 microamperes per K
Bandwidth (0.5 Vpp signal) Field to control 0 to 7.5 kHz; control to field 0.3 to 7.5 kHz (-3 dB)
Settling time / rise time 200 microseconds / 20 microseconds
Hazardous-area marking (1)G [Ex ia Ga] IIC, (1)D [Ex ia Da] IIIC, (M1) [Ex ia Ma] I
EU-type examination certificate BAS 99 ATEX 7060 X
Field terminals 1+, 3- Uo 25.4 V, Io 86.8 mA, Po 551 mW, Ci 12 nF, Li 0 mH
Zone 2 certificate TUV 99 ATEX 1499 X, marking Ex nA II T4
IECEx IECEx BAS 04.0016X; IECEx CML 15.0055X
Ambient temperature Minus 20 to 60 degrees C
Degree of protection IP20, screw terminals
Dimensions / mass 20 x 124 x 115 mm (W x H x D), housing type B2 / approx. 200 g
Mounting 35 mm DIN rail according to EN 60715

The input and output parameters for hazardous-area use are listed per terminal pair in the datasheet. Use the entity values of the exact terminals you wire, and refer to the certificate for the permitted cable parameters of your installation.

Typical applications in oil and gas, utilities, water and manufacturing

Loop-powered SMART transmitters for pressure, differential pressure, level and temperature are everywhere in refineries, gas gathering stations and desalination plants in Oman, and every one of them that sits in a hazardous area needs an interface to the control room. The KFD2-STC4-Ex1 fills that role in marshalling cabinets that feed DCS and PLC analog input cards, while letting HART communication pass through for configuration and diagnostics.

In utilities, water and wastewater works, and in manufacturing sites across the GCC, the same module is used where a transmitter is installed near a fuel store, a chemical dosing area or a biogas digester. Maintenance teams value the integrated test sockets because a handheld communicator can be connected without opening the loop, which shortens routine calibration and loop-check work on the KFD2-STC4-Ex1 channel.

Selection and compatibility notes for KFD2-STC4-Ex1

Start with the transmitter. Confirm that its supply voltage requirement, its maximum current and its entity parameters match the field-side data of the KFD2-STC4-Ex1, and confirm that the control system input accepts the output type of the module. The loop must also offer enough load resistance for HART communication, which is why the datasheet describes an internal 250 ohm resistor that can be used when the loop resistance is too low.

Next consider the cabinet. Devices of this family snap onto a Power Rail or are supplied through dedicated terminals, so decide early whether power will be distributed by rail or wired point to point. If your plant standard calls for a different housing width, channel count or SIL level, tell us before ordering so that we can compare neighbouring variants of the KFD2-STC4-Ex1 against your loop list.

Installation and commissioning of the KFD2-STC4-Ex1

Before mounting the KFD2-STC4-Ex1, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail or from its own supply terminals. Mount it on a 35 mm DIN rail in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits. Use terminals 1+ and 3 for a 3-wire or 2-wire transmitter as shown in the diagram, and use terminals 5- and 6+ only where the datasheet assigns them to your connection type.

Wire the KFD2-STC4-Ex1 only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KFD2-STC4-Ex1 can be compared with the commissioning values.

Maintenance and service life

The KFD2-STC4-Ex1 has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface. If HART communication becomes unreliable, check the loop resistance first, because the datasheet notes that the internal 250 ohm resistor can be used when the loop resistance is too low.

If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KFD2-STC4-Ex1 entity parameters before it returns to service.

Related products and ordering notes

Customers who ask for the KFD2-STC4-Ex1 often need neighbouring models or accessories from the same system, such as other KFD2 and KCD2 SMART transmitter power supplies, the Power Rail and power feed modules, and the neighbouring switch amplifiers and current drivers. If you are standardising a cabinet on one family, send us the loop list and we can quote the matching modules together.

When you send an enquiry for the KFD2-STC4-Ex1, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.

Frequently asked questions about KFD2-STC4-Ex1

The KFD2-STC4-Ex1 is a SIL 2 capable isolated barrier for SMART transmitters with HART, BRAIN and Foxboro support, 0/4 to 20 mA output into up to 800 ohm, a 20 to 35 V DC supply and a 20 mm wide DIN rail housing with ambient range of minus 20 to 60 degrees C.

Documents and quotation

A copy of the manufacturer datasheet for the KFD2-STC4-Ex1 is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KFD2-STC4-Ex1, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs KFD2-STC4-Ex1 SMART Transmitter Power

Answers from our engineering team on installation, compatibility and integration.

01What does the KFD2-STC4-Ex1 do?
It is a one-channel isolated barrier that powers 2-wire and 3-wire SMART transmitters in a hazardous area and passes the 0/4 to 20 mA signal and HART data to the safe area.
02Which SMART protocols does it support?
The datasheet lists HART, BRAIN and Foxboro, with digital signals transferred in both directions between the field and control side.
03What supply does the KFD2-STC4-Ex1 need?
It runs from 20 to 35 V DC, taken either from the Power Rail or from terminals 14+ and 15-, with a power consumption of 1.8 W.
04What is the maximum output load?
The output can drive loads from 0 to 800 ohm at 20 mA, and the output signal is 0/4 to 20 mA with an overload limit above 25 mA.
05How do I order the KFD2-STC4-Ex1?
Send an RFQ with the part number KFD2-STC4-Ex1, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.