Brand:

Beamex 8075784 BC15-Ex Power Supply for MC6-Ex

Description

Overview of Beamex BC15-Ex power supply for MC6-Ex Beamex 8075784

The Beamex 8075784 is the BC15-Ex power supply for the MC6-Ex intrinsically safe calibrator, with an input voltage of 100 to 240 VAC.

It is a typical replacement part for classified-area calibrator kits.

This page describes Beamex BC15-Ex power supply for MC6-Ex for buyers who need the exact part number Beamex 8075784. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the data below is taken from the manufacturer published product pages and brochures.

Key features of 8075784

  • Order code: 8075784.
  • Description: BC15-Ex power supply for MC6-Ex.
  • Input voltage: 100 to 240 VAC.
  • Mains frequency: 50 to 60 Hz.
  • Power cords (sold separately): EU 230 V 8081760; US 115 V 8081765; UK 240 V 8081770; AU 230 V 8081775.
  • Charging time of MC6-Ex pack: 10 hours from 0 to 100 percent.

Technical specifications for 8075784

Order code 8075784
Description BC15-Ex power supply for MC6-Ex
Input voltage 100 to 240 VAC
Mains frequency 50 to 60 Hz
Power cords (sold separately) EU 230 V 8081760; US 115 V 8081765; UK 240 V 8081770; AU 230 V 8081775
Charging time of MC6-Ex pack 10 hours from 0 to 100 percent

All values above come from the manufacturer documentation and may change with later revisions. Please quote 8075784 when you need the matching datasheet or a confirmation of the current revision.

Typical applications in Oman and the GCC

A dependable charger is essential for calibrators that are used on every shift. Instrument teams in Oman and the GCC rely on power supplies that accept a wide mains range and travel easily between plant, workshop and vehicle.

Spare supplies are also kept at remote sites, offshore platforms and contractor camps, where a damaged or misplaced charger would otherwise leave an instrument unusable until the next supply run.

The part is relevant wherever the related calibration equipment is used: oil and gas, utilities, water, process manufacturing and calibration service providers in Oman and the wider GCC.

Equipment used in Oman and the wider GCC faces high ambient temperatures, dust and coastal humidity. Keep instruments and accessories out of direct sun, avoid leaving them in closed vehicles, and allow cold equipment to acclimatise before use when moving from an air-conditioned room to an outdoor unit. Cap connectors and threads when they are not in use so that sand and moisture stay out.

Selection and compatibility notes for 8075784

The charger must not be used in a hazardous area. It is the only charger approved by the manufacturer for the MC6-Ex battery pack, so do not substitute a general-purpose supply.

Select the power cord separately according to the local plug type.

Before ordering 8075784, confirm the model and, where relevant, the serial number or option code of the instrument it will serve. Confirm voltage, plug type, thread type or pressure rating as applicable, and check the manufacturer documentation for the firmware or hardware revision of the equipment.

If an item looks similar but carries a different part number, do not assume interchangeability. A short note of the calibrator model and application lets us confirm the match for 8075784 before it is supplied.

Installation and commissioning of 8075784

Connect the power cord to the supply first, then to the mains, and finally to the calibrator charging socket. Check that the cord plug matches the local socket type; the power cord is a separate part number from 8075784. Allow the calibrator to charge in a dry, ventilated place within the temperature limits in its specification.

Do not cover the supply while charging, and do not use a damaged cable. Disconnect when charging is complete if the instrument will be stored for a long period.

Maintenance and care

Inspect the cable and plug regularly for cuts, kinks and heat marks and replace the unit if there is any damage. Keep the unit dry and away from dust and direct heat. Label each supply with the calibrator it belongs to so that the right one is used for each model.

Use 8075784 only with the calibrator it is listed for, because charger and battery are matched.

Calibration is only as useful as its records. Keep a log of serial numbers, certificate dates, replacement parts and any faults, and store the manufacturer documents with the equipment. This makes audits easier, helps predict when spares will be needed, and shortens the time needed to prepare a purchase request when a part has to be replaced at short notice.

Related products and ordering notes for 8075784

Related items are the matching battery pack, the country-specific power cord and a carrying case. List them together to receive a single quotation.

Hard-to-find and discontinued spare parts are a daily topic for maintenance planners in oil, gas, power and water facilities. When a plant standardises on one calibrator family, a small stock of the exact spares is far cheaper than a day of lost production, and an early enquiry gives the supplier time to confirm availability and shipping options to Oman and neighbouring countries.

Please note that Seven Star LLC prepares each quotation for 8075784 against the exact part number, so a request that quotes the number and the quantity is answered faster than a general description.

The part number 8075784 should be quoted exactly as printed in this page, because accessories and spares with similar descriptions often differ by one digit.

Frequently asked questions about 8075784

  • Which cords go with 8075784? The manufacturer lists EU 230 V (8081760), US 115 V (8081765), UK 240 V (8081770) and AU 230 V (8081775).
  • Can it be used in a hazardous area? No. It must not be used in a hazardous area.
  • What input range does it have? 100 to 240 VAC, according to the manufacturer documentation for 8075784.
  • Can it charge the standard MC6? The standard MC6 uses the BC15 (8081755); the BC15-Ex is intended for the MC6-Ex.
  • How long does charging take? About 10 hours for a full charge of the MC6-Ex pack.

Documents and quotation

The official Beamex MC6-Ex User Manual is attached to this page as a PDF. Its charging section describes the BC15-Ex charger for the MC6-Ex and the safety notes for charging an intrinsically safe calibrator. Share order code 8075784 together with your calibrator model and we will confirm the exact part in a written quotation.

Datasheets & Documents
  • PDF Datasheet Beamex MC6-Ex User Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.

Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.

Beamex company profile

Origin Founded in 1975 in Finland by four calibration technicians; first factory 1977
Headquarters Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992
Product families MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software
Typical duty Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters

Milestones

  • 1975: Four calibration technicians found the company in Finland.
  • 1977: The first factory opens.
  • 1992: ISO 9001 certification.

Beamex calibrators and accessories

Model Type Typical use
MC6 Advanced field calibrator and communicator Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results
MC6-Ex Intrinsically safe field calibrator Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit
MC6-T Temperature calibrator with integrated dry block Temperature sensors and transmitters, with multifunction electrical and pressure measurement
MC4, MC2 Documenting and hand-held process calibrators Routine loop, transmitter and switch checks in the field
FB, MB Field and metrology temperature dry blocks FB for field calibration; MB for higher-accuracy workshop and laboratory work
ePG, POC8 Electric pressure pump and automatic pressure controller Automated pressure calibration; POC8 for workshop calibration benches
PGC, PGM, PGL, PGPH, PGHH Hand pressure pumps Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH)
EXT modules External pressure modules Extending MC calibrators to additional ranges, 70 kPa to 100 MPa

Where Beamex equipment is used

Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.

Ordering Beamex equipment: what we need

State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.

Facts checked against Beamex company history and product information, October 2026.

FAQ

Questions about the Beamex 8075784 BC15-Ex Power Supply for MC6-Ex

Answers from our engineering team on installation, compatibility and integration.

01Which cords go with 8075784?
The manufacturer lists EU 230 V (8081760), US 115 V (8081765), UK 240 V (8081770) and AU 230 V (8081775).
02Can it be used in a hazardous area?
No. It must not be used in a hazardous area.
03What input range does it have?
100 to 240 VAC, according to the manufacturer documentation for 8075784.
04Can it charge the standard MC6?
The standard MC6 uses the BC15 (8081755); the BC15-Ex is intended for the MC6-Ex.
05How long does charging take?
About 10 hours for a full charge of the MC6-Ex pack.