- Automation & ControlView all 3,062 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Extech
Extech RH390 Precision Psychrometer, 2% RH Accuracy
Description
Extech RH390 precision psychrometer with 2% RH accuracy
The Extech RH390 is a handheld precision psychrometer for humidity and temperature checks in HVAC, cleanrooms, storage areas and process plants. It reads 0 to 100% RH with ±2% basic accuracy and a response time of under 30 seconds, and its dual backlit display can show humidity with temperature, dew point or wet bulb at the same time.
A slim body with rubberized sides allows one-hand operation, and data hold, min/max, auto power off with a disable option and a low battery indicator are included. The kit contains a carrying case and a 9 V battery.
Technical specifications of the RH390
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Extech / RH390 (RH390-NIST includes certificate traceable to NIST) |
| Humidity | 0 to 100% RH, ±2% RH basic accuracy, 0.1% resolution |
| Temperature (internal) | -30 to 100 °C (-22 to 199 °F), ±1 °C (±1.8 °F), 0.1 resolution |
| Dew point | -30 to 100 °C (-22 to 199 °F) |
| Wet bulb | 0 to 80 °C (32 to 176 °F) |
| RH response time | Less than 30 seconds |
| Display | Dual backlit: humidity with temperature, dew point or wet bulb |
| Functions | Data hold, min/max, auto power off with disable, low battery indicator |
| Power / supplied items | 9 V battery, carrying case |
| Dimensions / weight | 200 x 45 x 33 mm (7.8 x 1.7 x 1.3 in) / approx. 200 g |
The figures above are from the RH390 datasheet.
What dew point and wet bulb tell you with the RH390
Relative humidity alone depends on temperature, so a reading of 60% RH means different amounts of moisture in cool and warm air. Dew point is the temperature at which the air would begin to condense on a surface, and is the number that matters for protecting electrical equipment, painted steel and compressed air systems. The RH390 calculates dew point from the measured humidity and temperature, and also gives wet bulb temperature, which HVAC and cooling-tower engineers use in performance calculations.
The 2% RH accuracy, which is the best of the Extech handheld series, makes the instrument suitable for checks where tolerance matters, such as storage rooms for sensitive electronics or spare parts. Allow the sensor to equilibrate when moving between rooms with large differences in humidity, since the response time is quoted at under 30 seconds for a step change.
Typical uses of the RH390
- HVAC commissioning: confirm supply and return air conditions and cooling-coil performance.
- Switchrooms and control rooms: check humidity against equipment limits and condensation risk.
- Storage areas for spares, chemicals, paper and electronics.
- Cooling-tower and process checks using wet-bulb temperature.
- Comparing room conditions with building management system sensors.
For moisture in materials and surface temperature as well, see the Extech MO290; the RH390 is for air humidity and temperature.
Selection checklist for the RH390
- Confirm that a 2% RH accuracy and 0 to 100% RH range meet your tolerance.
- Decide whether dew point and wet bulb are required.
- Check that the temperature range of -30 to 100 °C suits the areas you test.
- Consider the NIST certificate version if humidity records are audited.
- Plan periodic calibration or a field check against a reference.
Care and calibration of the RH390
Keep the sensor away from condensing moisture, solvents, oil mist and dust, and do not touch the sensor element. After use in a very humid place, let it dry before storing in the case. The sensor drifts slowly with age, so check it against a reference at least once a year, or more often in harsh environments. Replace the 9 V battery when the indicator shows. Hold the RH390 away from your body, since breath and body heat influence the reading.
Applications of the RH390 in Oman and the GCC
Coastal plants face high humidity and salt-laden air, and desert plants face large day-to-night swings, so condensation inside electrical rooms and on pipework is a real risk. Facility teams use psychrometers to check that air-conditioned rooms hold the design condition, to document conditions for equipment warranties and to confirm that dehumidifiers work. The slim body is easy to carry on rounds.
Taking a reliable humidity reading
Hold the instrument in the air stream or at the point of interest for at least a minute, away from heat sources, windows and your breath. Record the reading with the time and the air temperature, then take a second reading after a few minutes to confirm it has settled. In a large room, take readings at several places and heights and average them. When humidity swings through the day, use the min/max function to capture the range during a visit.
Using the RH390 to assess condensation risk
Condensation forms when a surface is colder than the dew point of the air around it. Measure the air dew point with the instrument, then compare it with the temperature of the coldest surface in the area, such as a chilled water pipe, a metal enclosure or an outside wall. If the surface temperature is within a degree or two of the dew point, the risk is high and action is needed, for example improving insulation, adding dehumidification or raising the room temperature. Repeat the check at different times of day because humidity and surface temperature change.
Information to send with an RFQ for the RH390
- Part number RH390 and the required quantity
- Humidity and temperature range of the areas to be measured
- Whether a NIST calibration certificate is required
- Delivery location in Oman or the GCC and the required lead time
- Whether calibration documentation or a traceable calibration certificate is required
Documents and quotation
A datasheet for the Extech RH390 is attached on this page. It lists the humidity, temperature, dew point and wet bulb ranges.
Send us the part number RH390, the quantity and the delivery location in Oman or the GCC, and we will reply with availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
See also: Extech RPM33 Contact and Laser Photo Tachometer; Extech EX330 Autoranging Multimeter with Voltage Detector.
Datasheets & Documents
- Datasheet Extech RH390 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Extech Instruments is an American brand of handheld test and measurement instruments, founded in the early 1970s in Waltham, Massachusetts. FLIR Systems acquired Extech in 2007 for about $40 million, and FLIR itself became part of Teledyne in 2021. Extech is based in Nashua, New Hampshire, and makes meters for electrical, environmental and HVAC testing.
Extech company profile
| Founded | Early 1970s, Waltham, Massachusetts |
|---|---|
| Headquarters | Nashua, New Hampshire (since 2011) |
| Ownership | Teledyne FLIR |
| Acquired by FLIR | 2007 |
| Product families | True RMS clamp meters and multimeters, insulation testers, power analysers, IR thermometers, light meters, vibration meters, sound, humidity and air quality meters |
Milestones
- 2007: FLIR Systems acquires Extech.
- 2011: Extech moves to Nashua.
- 2021: FLIR becomes part of Teledyne.
Meters, testers and inspection tools
The Extech range includes multimeters and clamp meters, insulation and resistance testers, power analyzers, thermometers, light and sound level meters, anemometers, tachometers, vibration meters, moisture meters, borescopes and water quality meters. Each datasheet and user manual lists ranges, accuracy, safety category and ordering codes, and many models are listed with NIST-traceable calibration versions ordered by adding -NIST to the part number.
Supply through Seven Star LLC
Seven Star LLC is an independent supplier in Muscat that quotes Extech products for projects in Oman and the GCC, with the official Extech datasheet and user manual attached to each product page.
Extech products we list
Facts checked against FLIR's 2007 announcement and published Extech histories, October 2026.
FAQ
Questions about the Extech RH390 Precision Psychrometer, 2% RH Accuracy
Answers from our engineering team on installation, compatibility and integration.
01What humidity accuracy does the Extech RH390 offer?
The RH390 offers ±2% RH basic accuracy over 0 to 100% RH with a response time of less than 30 seconds.
02What can the RH390 display?
The dual backlit display shows humidity together with temperature, dew point or wet bulb.
03What is the temperature range of the RH390?
The internal temperature sensor covers -30 to 100 °C (-22 to 199 °F) with ±1 °C accuracy.
04Does the RH390 have data hold and min/max?
Yes. Data hold, min/max, auto power off with disable and a low battery indicator are included.
05What power does the RH390 use?
The RH390 runs on a 9 V battery, supplied with a carrying case.


















Reviews
There are no reviews yet.