- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Extech
Extech EX330 Autoranging Multimeter with Voltage Detector
Description
Extech EX330 autoranging compact multimeter with non-contact voltage detector
The Extech EX330 is a compact autoranging digital multimeter with a 4000-count display, 0.5% basic accuracy and a built-in non-contact AC voltage detector with a red LED and an audible beeper. It is the fully featured member of the EX300 series: besides voltage, current and resistance, it measures capacitance, frequency, duty cycle and Type K temperature, with a Relative function and a switchable °C/°F display.
Large 1 in (25 mm) digits make the display easy to read, and a tilt stand, protective holster, test leads, batteries and a general-purpose bead-wire probe come with the EX330. The EX310 (manual ranging) and EX320 (autoranging) are the simpler siblings.
Technical specifications of the EX330
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Extech / EX330 (EX330-NIST available) |
| Display | 4000 counts, large 1 in digits |
| Basic accuracy | 0.5% |
| Non-contact voltage detector | 100 to 600 V AC, red LED with beeper |
| DC voltage | 0.1 mV to 600 V |
| AC voltage | 0.1 mV to 600 V |
| AC/DC current | 0.1 µA to 10 A |
| Resistance | 0.1 Ω to 40 MΩ |
| Capacitance | 0.001 nF to 200 µF |
| Frequency / duty cycle | 0.001 Hz to 10 MHz / 0.1 to 99.9% |
| Temperature (Type K) | -20 to 750 °C (-4 to 1382 °F) |
| Other functions | Diode and continuity, data hold, relative, auto power off |
| Dimensions / weight | 147 x 76 x 42 mm (5.7 x 2.9 x 1.6 in) / approx. 260 g |
The figures above are from the EX300 series datasheet.
How the EX330 compares with the EX310 and EX320
| Model | Ranging | Display | Main difference |
|---|---|---|---|
| EX310 | Manual ranging | 2000 counts | Voltage, current, resistance, NCV |
| EX320 | Autoranging | 2000 counts | Resistance to 20 MΩ, current to 0.1 µA |
| EX330 | Autoranging | 4000 counts | Adds capacitance, frequency, temperature, duty cycle |
Choose the EX330 for general electrical maintenance where temperature and capacitor tests are part of the work, and the EX310 where a basic manual-ranging meter is enough. For ghost-voltage rejection and true RMS, move up to the EX350 series.
Everyday uses of the EX330
- Voltage and continuity checks on control panels and lighting circuits, starting with the NCV.
- Capacitor checks on motor start and run capacitors up to 200 µF.
- Temperature of bearings, terminals and heating elements with the Type K probe.
- Frequency and duty cycle checks on sensors and PWM signals.
- Current checks up to 10 A on small loads and control circuits.
Note that the EX330 is not a true RMS meter; for distorted waveforms and drives, use a true RMS meter such as the EX350.
Selection checklist for the EX330
- Confirm that voltage up to 600 V and current to 10 A cover your measurements.
- Decide whether capacitance, frequency and temperature are needed (EX330) or not (EX310, EX320).
- Check that a 4000-count display and 0.5% accuracy meet your needs.
- Plan for spare leads and batteries.
- Decide whether the NIST-calibrated version is required.
Care and safe use of the EX330
Use the NCV to indicate live conductors, but prove circuits dead with the voltage function. Do not measure current above 10 A, and never apply voltage on the current or resistance ranges. Keep the leads in good condition, replace the batteries when the low battery indicator appears, and keep the protective holster on in the tool bag. Remove the batteries for long storage of the EX330.
Applications of the EX330 in Oman and the GCC
A compact autoranging multimeter is the everyday tool for electricians and instrument technicians in plants, workshops and buildings across Oman and the GCC. The Type K temperature input is handy for checking hot terminals and bearings in warm switchrooms, and the capacitance range checks the many single-phase motor capacitors found in air-conditioning units. The large digits are readable in poorly lit panels.
Measuring temperature and capacitance
For temperature, plug the Type K probe into the temperature inputs, select the temperature function, and hold the bead against the surface until the value settles. For capacitance, discharge the capacitor first with a suitable resistor, remove it from the circuit, select the capacitance range and connect the leads; use the relative function to cancel lead capacitance on the smallest values. Compare the measured value with the nameplate rating, allowing the tolerance printed on the capacitor.
Checking a motor circuit step by step with the EX330
Begin with the NCV at the starter and the motor terminal box to see which conductors are live. Switch to the AC voltage range to confirm supply voltage at the starter, and compare the three phases. After isolation and lock-out, use the resistance range between phases of the motor winding to compare readings, which should be nearly equal on a healthy machine, and between each phase and earth, where a low reading suggests a winding fault that an insulation tester should then confirm. Finish with a temperature check of the motor frame or bearing housing, using the Type K probe, once the machine has run for some time.
Write down every reading with the date and the tag number, so that the next visit can be compared with the same circuit. If a reading looks wrong, repeat it with a second meter before taking action, because a flat battery or a poorly seated lead can mislead.
Information to send with an RFQ for the EX330
- Part number EX330 and the required quantity
- Voltage, current and temperature ranges needed
- Whether the EX310 or EX320 would be sufficient, or a NIST certificate is needed
- Delivery location in Oman or the GCC and the required lead time
- Whether calibration documentation or a traceable calibration certificate is required
Documents and quotation
A datasheet for the Extech EX330 is attached on this page. It covers the EX310, EX320 and EX330 models.
Send us the part number EX330, the quantity and the delivery location in Oman or the GCC, and we will reply with availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Extech Multimeters Range
Seven Star LLC supplies models from the Extech Multimeters range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Extech EX350 True RMS Multimeter with LoZ and NCV | Electrical Testers & Multimeters | View details |
| Extech EX330 Autoranging Multimeter with Voltage Detector | Electrical Testers & Multimeters | You are viewing this model |
Datasheets & Documents
- Datasheet Extech EX330 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Extech Instruments is an American brand of handheld test and measurement instruments, founded in the early 1970s in Waltham, Massachusetts. FLIR Systems acquired Extech in 2007 for about $40 million, and FLIR itself became part of Teledyne in 2021. Extech is based in Nashua, New Hampshire, and makes meters for electrical, environmental and HVAC testing.
Extech company profile
| Founded | Early 1970s, Waltham, Massachusetts |
|---|---|
| Headquarters | Nashua, New Hampshire (since 2011) |
| Ownership | Teledyne FLIR |
| Acquired by FLIR | 2007 |
| Product families | True RMS clamp meters and multimeters, insulation testers, power analysers, IR thermometers, light meters, vibration meters, sound, humidity and air quality meters |
Milestones
- 2007: FLIR Systems acquires Extech.
- 2011: Extech moves to Nashua.
- 2021: FLIR becomes part of Teledyne.
Meters, testers and inspection tools
The Extech range includes multimeters and clamp meters, insulation and resistance testers, power analyzers, thermometers, light and sound level meters, anemometers, tachometers, vibration meters, moisture meters, borescopes and water quality meters. Each datasheet and user manual lists ranges, accuracy, safety category and ordering codes, and many models are listed with NIST-traceable calibration versions ordered by adding -NIST to the part number.
Supply through Seven Star LLC
Seven Star LLC is an independent supplier in Muscat that quotes Extech products for projects in Oman and the GCC, with the official Extech datasheet and user manual attached to each product page.
Extech products we list
Facts checked against FLIR's 2007 announcement and published Extech histories, October 2026.
FAQ
Questions about the Extech EX330 Autoranging Multimeter with Voltage
Answers from our engineering team on installation, compatibility and integration.
01What is the Extech EX330?
The EX330 is a compact autoranging multimeter with a 4000-count display, 0.5% basic accuracy and a non-contact voltage detector.
02Does the EX330 measure temperature?
Yes. It measures Type K temperature from -20 to 750 °C, and a general-purpose bead-wire probe is supplied.
03What current can the EX330 measure?
The EX330 measures AC/DC current from 0.1 µA to 10 A directly.
04What is the difference between the EX330 and the EX310?
The EX310 is a manual-ranging meter with 2000 counts; the EX330 is autoranging and adds capacitance, frequency, duty cycle and temperature.
05Is the EX330 a true RMS meter?
No. The datasheet does not list true RMS for the EX300 series; choose a true RMS meter such as the EX350 for distorted waveforms.


















Reviews