Extech EX655 600 A True RMS AC/DC Clamp Meter with LoZ

Description

Extech EX655 600 A true RMS AC/DC clamp meter with LoZ

The Extech EX655 is a fully loaded 600 A true RMS AC/DC clamp meter with a 30 mm (1.18 in) jaw for conductors up to 350 MCM. It includes a low-impedance (LoZ) mode to remove ghost-voltage readings, a low-pass filter (LPF) for variable-frequency-drive signals, an inrush mode to capture motor start-up surges, a DC zero mode, an LCD trending bargraph, and a micro-amp range for HVAC flame-rod testing. The EX655 counts 12 functions, including frequency and Type K temperature.

A 6000-count backlit display, a non-contact AC voltage detector with LED, an LED worklight, data hold, min/max and relative modes complete the meter. The EX655 is supplied with test leads, a general-purpose bead-wire temperature probe and three AAA batteries. The EX650 is the AC-only sibling.

Technical specifications of the EX655

Parameter Specification
Manufacturer / part number Extech / EX655 (EX655-NIST available)
Display 6000-count backlit LCD with trending bargraph
AC current (true RMS) 60 A and 600 A ranges, 0.01 A resolution, ±2.5% of reading
DC current 60 A and 600 A, 0.01 A resolution, ±2.5% of reading
AC/DC micro-amp 600 µA, 0.1 µA resolution
DC voltage 1000 V, 0.1 mV resolution, ±0.8%
AC voltage 750 V, 1 mV resolution, ±1.2%
Non-contact voltage 100 to 1000 V
Resistance / capacitance 60 MΩ (0.1 Ω) / 60 mF (0.01 nF)
Frequency 10 Hz to 1 MHz
Temperature (Type K) -40 to 1000 °C (-40 to 1832 °F), 1 degree resolution
Special modes LoZ, LPF, inrush, DC zero, data hold, min/max, relative, worklight, auto power off
Jaw 30 mm (1.18 in), conductors up to 350 MCM
Dimensions / weight 228 x 77 x 41 mm (9 x 3 x 1.6 in) / approx. 265 g

The figures above are from the EX65x series datasheet.

Inrush, LPF and LoZ on the EX655

Motor start-up current can be many times the running current, and the inrush mode of the EX655 captures it so that technicians can compare it with starter settings and supply capacity. For drive-fed motors, the low-pass filter attenuates the carrier frequency so the reading reflects the fundamental current that the motor uses. The LoZ mode loads the voltage input so that ghost voltages disappear and genuine voltages remain, which prevents false readings when checking isolation.

The LCD trending bargraph shows the direction of a changing reading at a glance, which helps while adjusting a load or watching a fluctuating current. The DC zero mode removes the sensor offset before a DC current measurement so low DC currents are accurate.

Where the EX655 fits

Choose the EX655 when you need AC and DC current to 600 A with drive, inrush and ghost-voltage features in a compact meter. For 1000 A with IR thermometer, take the Extech EX840A; for 400 A true RMS AC with Type K, the MA443; for 1500 A and 40,000 counts, the MA1500.

  • Drive-fed pumps and fans: use LPF for stable current readings.
  • Motor start checks: use inrush to see peak start-up current.
  • HVAC: micro-amp flame-rod checks and temperature.
  • Battery or DC supply checks: use DC current with DC zero.

Selection checklist for the EX655

  • Confirm that the maximum current is below 600 A and the conductor fits a 30 mm jaw (350 MCM).
  • Decide whether DC current is needed (EX655) or AC only (EX650).
  • Confirm that LoZ, LPF and inrush are required by your work.
  • Check the need for the micro-amp range for HVAC flame sensing.
  • Decide whether the NIST-calibrated version is required.

Safe use of the EX655

Use the NCV as an indication only and prove the circuit dead with the voltage function before touching conductors. Keep the leads out of the meter when measuring current with the jaw, clamp one conductor, and keep the jaw faces clean. Replace the three AAA batteries as soon as the low battery indicator appears, and store the EX655 in a clean place.

Applications of the EX655 in Oman and the GCC

Maintenance teams in oil and gas, utilities and building services use a 600 A clamp for everyday motor and feeder checks. Drive-fed pumps and fans are common in water and desalination plants and in district cooling, so the LPF is relevant. The worklight helps in dim panels, and the ghost-voltage protection avoids false readings on long cables that share trays.

Recording start-up current

Select the inrush mode, clamp the motor feeder, and start the motor while watching the display. Note the peak value and the time it takes the current to fall to the running value. Compare the peak with the nameplate locked-rotor current and the protection settings. A start-up peak that is much higher than expected, or that takes too long to settle, points to a mechanical load problem, a supply drop or a faulty starter.

Information to send with an RFQ for the EX655

  • Part number EX655 and the required quantity
  • Maximum current and conductor size
  • Whether AC only (EX650) or AC/DC (EX655) is needed
  • Delivery location in Oman or the GCC and the required lead time
  • Whether calibration documentation or a traceable calibration certificate is required

Storage, handling and spares for the Extech EX655

Store the Extech EX655 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.

  • Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
  • Use only leads and accessories rated for the same or a higher measurement category than the work you do.
  • Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
  • Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.

If your team uses several units of the Extech EX655, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.

Documents and quotation

A datasheet for the Extech EX655 is attached on this page. It covers the EX650 and EX655 models.

Send us the part number EX655, the quantity and the delivery location in Oman or the GCC, and we will reply with availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Extech Clamp Meters Range

Seven Star LLC supplies models from the Extech Clamp Meters range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Extech 380950 80 A Mini AC/DC Clamp Meter, 1 mA ResolutionElectrical Testers & MultimetersView details
Extech 380976-K 1000 A AC Power Clamp Meter Kit, 1 and 3 PhaseElectrical Testers & MultimetersView details
Extech MA1500 1500 A True RMS AC/DC Clamp Meter with NCVElectrical Testers & MultimetersView details
Extech MA63 60 A True RMS AC/DC Clamp Meter with NCVElectrical Testers & MultimetersView details
Extech MA443 400 A True RMS AC Clamp Meter with NCV and Type KElectrical Testers & MultimetersView details
Extech EX840A 1000 A True RMS AC/DC Clamp Meter with IRElectrical Testers & MultimetersView details
Extech EX655 600 A True RMS AC/DC Clamp Meter with LoZElectrical Testers & MultimetersYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Extech Instruments is an American brand of handheld test and measurement instruments, founded in the early 1970s in Waltham, Massachusetts. FLIR Systems acquired Extech in 2007 for about $40 million, and FLIR itself became part of Teledyne in 2021. Extech is based in Nashua, New Hampshire, and makes meters for electrical, environmental and HVAC testing.

Extech company profile

Founded Early 1970s, Waltham, Massachusetts
Headquarters Nashua, New Hampshire (since 2011)
Ownership Teledyne FLIR
Acquired by FLIR 2007
Product families True RMS clamp meters and multimeters, insulation testers, power analysers, IR thermometers, light meters, vibration meters, sound, humidity and air quality meters

Milestones

  • 2007: FLIR Systems acquires Extech.
  • 2011: Extech moves to Nashua.
  • 2021: FLIR becomes part of Teledyne.

Meters, testers and inspection tools

The Extech range includes multimeters and clamp meters, insulation and resistance testers, power analyzers, thermometers, light and sound level meters, anemometers, tachometers, vibration meters, moisture meters, borescopes and water quality meters. Each datasheet and user manual lists ranges, accuracy, safety category and ordering codes, and many models are listed with NIST-traceable calibration versions ordered by adding -NIST to the part number.

Supply through Seven Star LLC

Seven Star LLC is an independent supplier in Muscat that quotes Extech products for projects in Oman and the GCC, with the official Extech datasheet and user manual attached to each product page.

Extech products we list

Family Examples
Portable Test & Measurement IR400 Mini IR Thermometer with Laser Poi…, LT300 Digital Light Meter, MA445 400 A True RMS AC/DC Clamp Meter w…, MG500 10 kV Digital High Voltage Insulat…, PQ3450 3-Phase Power Analyzer and Datalo…, VB450 Pocket Vibration Meter

Facts checked against FLIR's 2007 announcement and published Extech histories, October 2026.

FAQ

Questions about the Extech EX655 600 A True RMS AC/DC Clamp Meter with

Answers from our engineering team on installation, compatibility and integration.

01What are the main features of the Extech EX655?
The EX655 is a 600 A true RMS AC/DC clamp meter with LoZ, low-pass filter, inrush mode, DC zero, NCV, worklight and a micro-amp range.
02What jaw size does the EX655 have?
The jaw is 1.18 in (30 mm) and accommodates conductors up to 350 MCM.
03What is the difference between the EX650 and the EX655?
The EX650 measures AC current only with 9 functions; the EX655 has 12 functions including AC/DC current, frequency, Type K temperature, LPF, inrush and DC zero.
04Does the EX655 measure temperature?
Yes. It measures Type K temperature from -40 to 1000 °C, and a general-purpose bead-wire probe is supplied.
05What batteries does the EX655 use?
The EX655 uses three AAA batteries, supplied along with test leads and the temperature probe.