Brand: Fluke
Fluke 902 FC True-RMS HVAC Clamp Meter, Wireless
Description
902 FC wireless HVAC clamp meter explained
The Fluke 902 FC True-RMS HVAC Clamp Meter (902 FC) is a true-RMS clamp meter for HVAC systems. It measures AC current to 600 A, voltage to 600 V, resistance to 60 kΩ, capacitance, microamps and contact temperature, and sends readings to a smartphone. Seven Star LLC supplies 902 FC in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The 902 FC is the HVAC specialist of the clamp family. The table decodes its key data.
| Element | Value | Meaning |
|---|---|---|
| 902 | Model | HVAC clamp model |
| FC | Fluke Connect | Wireless smartphone link |
| 200 µA | Flame-sensor current | DC microamps |
| CAT III 600 V / CAT IV 300 V | Category | Dual rating |
902 FC technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / 902 FC |
| AC current via jaw | 600.0 A, 2.0% ± 5 digits (45 Hz to 65 Hz) |
| AC / DC voltage | 600.0 V, 1.5% ± 5 digits |
| Resistance | 600 Ω / 6000 Ω / 60.00 kΩ, 1% ± 5 digits |
| Capacitance | 100.0 / 1000 µF, 1% ± 4 digits |
| DC microamps | 200 µA, 1% ± 5 digits |
| Contact temperature | -40 °C to 400 °C, 1% ± 8 digits |
| Dimensions / weight | 230 x 83.7 x 45.4 mm / 419 g |
| Battery | Two AA alkaline |
| Safety | CAT III 600 V / CAT IV 300 V |
Values are from the manufacturer product page and 902 FC datasheet.
How the Fluke 902 FC True-RMS HVAC Clamp Meter works
The jaw senses AC current, while the leads and the 80BK probe provide voltage, resistance, capacitance, microamps and temperature, which are the checks an HVAC technician makes on compressors, fans, capacitors and flame sensors.
Bluetooth to Fluke Connect sends the data to a phone for logging and reporting. A technician can also place the clamp, close the panel and read from a distance to reduce exposure.
Key features
- AC current to 600 A
- Microamps for flame sensors
- Contact temperature to 400 °C
- Capacitance to 1000 µF
- Fluke Connect wireless
Where 902 FC fits and related Fluke models
The 902 FC is the clamp counterpart of the 116 HVAC multimeter. Use the 902 FC when current through conductors is needed; use the 116 when you need direct DC and AC measurement on a bench.
It has no DC current measurement through the jaw.
Selection checklist for 902 FC
Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.
- AC-only jaw current.
- Temperature probe included.
- Smartphone use.
- Rating CAT III 600 V.
Safe use, care and maintenance of 902 FC
- Close the jaw fully and check that the faces are clean. Dirt or rust on the jaw faces causes reading errors, and a jaw that does not close completely should be taken out of service.
- Clamp only one conductor at a time. Two conductors of a single-phase pair or a three-phase set cancel each other and the 902 FC will show a value close to zero.
- Verify the clamp on a known live circuit before and after any test that decides whether equipment is safe to touch.
- Replace batteries when the low-battery indicator appears and remove them for long storage. Inspect the test leads for damage before each use of the voltage and resistance functions.
- Keep the jaw and display free of dust. In dusty Gulf sites, use the supplied case and wipe the instrument after switchgear room work.
- Respect the maximum conductor size and never clamp bare busbars unless the rating and your site procedure allow it. Treat the clamp as a measuring tool, not a switch or an isolator.
- Allow the instrument to reach ambient temperature after moving it from an air-conditioned vehicle into a hot plant area, so that condensation does not form inside the housing and the display settles.
- Schedule periodic calibration through your quality system, and keep the certificate with the instrument record so that readings used for reports remain traceable.
Typical applications of 902 FC in Oman and the GCC
Clamp meters are used for load checks on motors, feeders, chillers and pump drives. In Oman, maintenance teams at oil and gas plants, power and water utilities, desalination units and petrochemical sites use them for current surveys without opening circuits. A clamp reading showing a motor drawing more than its nameplate current points to a mechanical overload, a supply imbalance or a failing winding, while a reading near zero on a running pump suggests a lost phase or dry running. Because the circuit stays intact, these checks can be done on live equipment under a permit, which keeps downtime low during the hot summer months when cooling and pumping loads peak.
In Oman, chiller and air-handling-unit technicians in commercial and industrial buildings use the 902 FC to check compressor current, capacitors and temperature differentials during peak cooling season.
902 FC compared with nearby models
| Model | DC jaw current | Microamps | Temperature |
|---|---|---|---|
| 325 | Yes | No | Yes |
| 902 FC | No | Yes | Yes |
| 116 | Not applicable | Yes | Yes |
The 116 is a multimeter, not a clamp.
Information to send with an RFQ for 902 FC
To prepare an accurate quotation, please send:
- Exact model 902 FC and the quantity required.
- Maximum conductor size and expected current, so the jaw or flexible probe option can be confirmed.
- Whether wireless or smartphone use is needed on site.
- Any extra accessories such as a hanging strap, leads or a case.
- Calibration traceability paperwork if required on delivery.
- Delivery point in Oman or elsewhere in the GCC and the required date.
Storage, handling and spares for the Fluke 902 FC
Store the Fluke 902 FC in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.
- Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
- Use only leads and accessories rated for the same or a higher measurement category than the work you do.
- Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
- Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.
If your team uses several units of the Fluke 902 FC, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.
Documents and quotation
A manufacturer datasheet for the Fluke 902 FC True-RMS HVAC Clamp Meter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.
For a quotation, send the part number 902 FC, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.
Datasheets & Documents
- Datasheet Fluke 902 FC Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 902 FC True-RMS HVAC Clamp Meter, Wireless
Answers from our engineering team on installation, compatibility and integration.
01Why does the 902 FC have microamps?
HVAC flame sensors work in the microamp range; the 902 FC measures up to 200 µA DC.
02What current can the jaw measure?
The jaw measures up to 600 A AC with 2.0% plus 5 digits accuracy from 45 Hz to 65 Hz.
03Does it measure temperature?
Yes, from -40 °C to 400 °C with the included 80BK probe.
04Can it log to a phone?
Yes, it sends readings over Bluetooth to the Fluke Connect application on a smartphone or tablet.
05What is its rating?
It is rated CAT III 600 V and CAT IV 300 V under IEC 61010-2-032 and IEC 61010-2-033.


















Reviews
There are no reviews yet.