Brand: Fluke
Fluke 113 Utility Digital Multimeter with VCHEK LoZ
Description
113 utility multimeter with VCHEK low-impedance mode explained
The Fluke 113 Utility Digital Multimeter (113) is a utility-grade digital multimeter for basic electrical testing. Its VCHEK LoZ position shows AC or DC voltage and automatically falls back to a continuity test when no voltage is present. Seven Star LLC supplies 113 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
VCHEK is the identifying feature of the 113, decoded in the table together with the other key data.
| Element | Value | Meaning |
|---|---|---|
| 113 | Model | Utility model of the 110 series |
| VCHEK LoZ | Dial position | Voltage and continuity from one setting |
| ~3 kΩ | Nominal LoZ input impedance | Low load to suppress ghost voltages |
| CAT IV 600 V | Category per specification table | IEC 61010-2-033 |
113 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / 113 |
| VCHEK voltage | 6.000 V / 60.00 V / 600.0 V, 2.0% + 3 (DC, 45 Hz to 500 Hz) |
| Diode test | 2.000 V range, 2.0% + 3 |
| Continuity | Beeper at 250 Ω, detects opens or shorts of 500 µs or longer |
| Resistance | 600.0 Ω to 60.00 kΩ, 0.9% + 1 to + 2 |
| Capacitance | 1000 nF to 9999 µF, 1.9% + 2 |
| Display | 3 3/4 digits, 6000 counts, 4 per second |
| Max voltage to earth | 600 V |
| Operating temperature | -10 °C to 50 °C |
| Battery | 9 V alkaline, about 300 hours typical |
| Size / weight | 167.1 x 85.1 x 46.0 mm / 404 g |
Data come from the manufacturer product page and Fluke 113 data sheet. Note the minimum measurable input in VCHEK autorange is 3 V DC.
How the Fluke 113 Utility Digital Multimeter works
On the VCHEK LoZ setting the 113 first looks for voltage. If it finds AC or DC it displays the value, rejecting ghost voltage from nearby wires through its low input impedance. If none is present it runs a continuity test, so one dial position answers both questions a technician usually asks first.
Min/Max records fluctuations, and the meter offers auto and manual ranging, diode test and capacitance. Low-impedance readings load the circuit and can trip RCDs when measuring phase to earth.
Key features
- VCHEK LoZ voltage and continuity
- Large backlit display
- Integrated holster with probe holders
- Min/Max function
- Diode and capacitance functions
Where 113 fits and related Fluke models
The 113 is the simplest and most utility-oriented meter in the 110 line, and has no current ranges. Where current to 10 A is needed, use the 114, 115 or 116. Where plant measurements to 1000 V are needed, use the 170 series.
For go/no-go work with automatic voltage type detection, the 114 is the closest alternative.
Selection checklist for 113
Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.
- No current measurement: the specification table lists none.
- Voltage up to 600 V and a 3 V DC minimum in VCHEK autorange.
- Low-impedance mode may trip RCDs.
- Wait one minute after a voltage measurement before ohms or capacitance, per the footnote.
Safe use, care and maintenance of 113
- Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 113 touches any live circuit.
- Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
- Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 113 Utility Digital Multimeter.
- Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
- Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.
Typical applications of 113 in Oman and the GCC
Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.
Utility workers, linesmen and maintenance electricians use the 113 for quick checks on lighting circuits, small power and switch gear. In Oman it fits camp maintenance, facility management and utility field crews that need an inexpensive, rugged voltage-and-continuity meter.
113 compared with nearby models
| Model | Current measurement | LoZ | Rating |
|---|---|---|---|
| 113 | No (per specification) | VCHEK LoZ | CAT IV 600 V |
| 114 | Yes, to 10 A | AutoVolt LoZ | CAT III 600 V |
| 115 | Yes, to 10 A | No | CAT III 600 V |
Always read the model-specific data sheet; rating statements differ between product pages.
Information to send with an RFQ for 113
To prepare an accurate quotation, please send:
- Exact model 113 and the quantity required.
- Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
- Required test lead type and any extra clips or probes.
- Temperature probe, case or magnetic hanger requirements.
- Whether calibration traceability paperwork is needed on delivery.
- Delivery point in Oman or elsewhere in the GCC and the required date.
Storage, handling and spares for the Fluke 113
Store the Fluke 113 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.
- Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
- Use only leads and accessories rated for the same or a higher measurement category than the work you do.
- Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
- Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.
If your team uses several units of the Fluke 113, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.
Documents and quotation
A manufacturer datasheet for the Fluke 113 Utility Digital Multimeter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.
For a quotation, send the part number 113, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.
Other Models in the Fluke 110 Series Dmm Range
Seven Star LLC supplies models from the Fluke 110 Series Dmm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Fluke 115 True-RMS Field Technician Digital Multimeter | Electrical Testers & Multimeters | View details |
| Fluke 116 HVAC True-RMS Multimeter with Temperature and uA | Electrical Testers & Multimeters | View details |
| Fluke 114 True-RMS Electrical Multimeter with AutoVolt | Electrical Testers & Multimeters | View details |
| Fluke 113 Utility Digital Multimeter with VCHEK LoZ | Electrical Testers & Multimeters | You are viewing this model |
Datasheets & Documents
- Datasheet Fluke 113 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 113 Utility Digital Multimeter with VCHEK LoZ
Answers from our engineering team on installation, compatibility and integration.
01What does VCHEK mean on the Fluke 113?
VCHEK is a low-impedance voltage function that shows AC or DC voltage and rejects ghost voltage, then performs a continuity test if no voltage is present.
02Does the 113 measure current?
The specification table does not list a current function for the 113. Use a 114, 115, 116 or a clamp meter for current.
03What is the LoZ input impedance?
The nominal VCHEK input impedance is about 3 kΩ, so it loads the circuit and removes induced ghost voltage.
04Can the 113 test capacitors?
Yes, capacitance ranges run from 1000 nF up to 9999 µF with 1.9% + 2 accuracy up to 1000 µF.
05How long is the battery life?
About 300 hours typical on an alkaline 9 V battery without the backlight, according to the manufacturer.


















Reviews
There are no reviews yet.