Fluke 114 True-RMS Electrical Multimeter with AutoVolt

Description

114 go/no-go electrical multimeter with AutoVolt explained

The Fluke 114 True-RMS Electrical Multimeter (114) is a compact true-RMS multimeter built for go/no-go electrical testing. AutoVolt picks AC or DC voltage automatically, and the LoZ function loads the circuit to remove ghost voltages that mislead a high-impedance meter. Seven Star LLC supplies 114 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The key to the 114 is its automatic voltage mode, decoded in the table below along with the other identifiers.

Element Value Meaning
114 Model Go/no-go model of the 110 series
AutoVolt Automatic AC/DC selection Meter chooses the voltage type present
LoZ Low-impedance input Collapses ghost voltage from adjacent wiring
CAT III 600 V Safety category Independently tested

114 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 114
DC voltage 6.000 V to 600.0 V, 0.5% + 2
AC voltage (true-RMS) 6.000 V to 600.0 V, 1.0% + 3 (45 Hz to 500 Hz)
Auto-V / LoZ 600.0 V, 2.0% + 3
Resistance 600.0 Ω to 40 MΩ, 0.9% + 1 up to 6 MΩ
Continuity Beeper at 250 Ω, detects opens or shorts of 500 µs or longer
Display 6000 counts, bar graph 33 segments
Max voltage to earth 600 V
Operating / storage temperature -10 °C to +50 °C / -40 °C to +60 °C
Battery 9 V alkaline, about 400 hours typical
Size / weight 167 x 84 x 46 mm / 550 g
Warranty 3 years

Values are taken from the manufacturer product page and the Fluke 114 data sheet.

How the Fluke 114 True-RMS Electrical Multimeter works

In AutoVolt mode the 114 senses whether the voltage at the input is AC or DC and switches to measure it, so the technician does not have to choose before probing. With the LoZ selection, the meter applies a low input impedance. A real supply stays at its value, while induced ghost voltage from neighbouring cables collapses to near zero, giving a clearer yes or no.

The 114 does not include the frequency, capacitance or temperature functions found on the 115 and 116; that is what keeps it simple. It still true-RMS measures AC and has a backlight and easy-open battery door.

Key features

  • AutoVolt automatic AC/DC selection
  • LoZ mode to reject ghost voltage
  • White LED backlight
  • Easy-open battery door
  • Holster with probe holders

Where 114 fits and related Fluke models

The 114 is the simplest meter in the 110 line. If your technicians mainly answer is-there-voltage questions, the 114 gives quick answers and rejects ghost voltages. If they also test capacitors or frequency, the 115 is the broader choice, and the 116 is the HVAC variant.

Note that LoZ mode loads the circuit; on RCD or GFCI protected circuits it can cause a trip when measuring phase to earth, so use caution.

Selection checklist for 114

Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.

  • Ghost-voltage issues in long cable runs or trays favour the 114.
  • No capacitance, frequency or temperature function.
  • CAT III 600 V; not for 1000 V systems.
  • Standard leads are supplied; check accessory needs.

Safe use, care and maintenance of 114

  • Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 114 touches any live circuit.
  • Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
  • Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 114 True-RMS Electrical Multimeter.
  • Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
  • Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.

Typical applications of 114 in Oman and the GCC

Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.

The 114 suits electricians doing fault finding on lighting circuits, small power and control wiring in plant buildings, camps and commercial sites in Oman, where long parallel cable runs often induce phantom voltages and a plain high-impedance meter gives confusing readings.

114 compared with nearby models

Model AutoVolt / LoZ Capacitance Frequency
113 VCHEK LoZ Yes (per data sheet) See data sheet
114 Yes No No
115 No Yes Yes
116 No Yes Yes

Comparison is limited to functions stated in the manufacturer material for each model.

Information to send with an RFQ for 114

To prepare an accurate quotation, please send:

  • Exact model 114 and the quantity required.
  • Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
  • Required test lead type and any extra clips or probes.
  • Temperature probe, case or magnetic hanger requirements.
  • Whether calibration traceability paperwork is needed on delivery.
  • Delivery point in Oman or elsewhere in the GCC and the required date.

Storage, handling and spares for the Fluke 114

Store the Fluke 114 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.

  • Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
  • Use only leads and accessories rated for the same or a higher measurement category than the work you do.
  • Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
  • Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.

If your team uses several units of the Fluke 114, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.

Documents and quotation

A manufacturer datasheet for the Fluke 114 True-RMS Electrical Multimeter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.

For a quotation, send the part number 114, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.

Other Models in the Fluke 110 Series Dmm Range

Seven Star LLC supplies models from the Fluke 110 Series Dmm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Fluke 115 True-RMS Field Technician Digital MultimeterElectrical Testers & MultimetersView details
Fluke 116 HVAC True-RMS Multimeter with Temperature and uAElectrical Testers & MultimetersView details
Fluke 114 True-RMS Electrical Multimeter with AutoVoltElectrical Testers & MultimetersYou are viewing this model
Fluke 113 Utility Digital Multimeter with VCHEK LoZElectrical Testers & MultimetersView details
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 114 True-RMS Electrical Multimeter with

Answers from our engineering team on installation, compatibility and integration.

01What is AutoVolt on the Fluke 114?
AutoVolt senses whether AC or DC voltage is present and selects the right mode automatically, which speeds up go/no-go testing.
02What does LoZ do?
LoZ is a low-input-impedance mode that loads the circuit so that ghost voltages from adjacent wiring drop away while real voltage remains.
03Can the 114 trip an RCD?
Low-impedance measurements may trip RCD or GFCI protected circuits when measuring phase to earth. Use LoZ only where that is acceptable.
04Is the 114 true-RMS?
Yes, it displays true-RMS voltage readings with 6000-count resolution and a 33-segment bar graph.
05What is the 114 rated for?
It is rated CAT III 600 V under IEC 61010-2-033, with a maximum 600 V between any terminal and earth ground.