Brand: Fluke
Fluke 116 HVAC True-RMS Multimeter with Temperature and uA
Description
116 HVAC multimeter with temperature and microamps explained
The Fluke 116 HVAC True-RMS Multimeter (116) is a true-RMS digital multimeter designed for heating, ventilation and air-conditioning work. In addition to the standard functions it has a built-in thermometer input and a microamp range for testing flame sensors. Seven Star LLC supplies 116 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The identifiers below show what makes this model different from the 114, 115 and 117 in the same family.
| Element | Value | Meaning |
|---|---|---|
| 116 | Model | HVAC model of the 110 series |
| Temperature input | Type-K thermocouple | -40 °C to 400 °C; 80BK probe in the box |
| 600 µA range | Flame-sensor testing | AC and DC microamp ranges |
| CAT III 600 V | Safety category | Tested for use in this environment |
116 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / 116 |
| DC voltage | Up to 600 V, 0.5% + 2 |
| AC voltage (true-RMS) | Up to 600 V, 1.0% + 3 (45 Hz to 500 Hz) |
| Auto-V / LoZ | 600 V range, 2.0% + 3 |
| Microamps | 600.0 µA, DC 1.0% + 2, AC 1.5% + 3 |
| Temperature (Type-K) | -40 °C to 400 °C, 1% + 10, excluding probe |
| Resistance | Up to 40 MΩ |
| Capacitance | Up to 9999 µF; Lo-Z capacitance 1 nF to 500 µF |
| Frequency | Up to 50 kHz, 0.1% + 2 |
| Battery | 9 V alkaline, about 400 hours typical without backlight |
| Size / weight | 167 x 84 x 46 mm / 550 g |
| Warranty | 3 years |
Figures come from the manufacturer product page and technical data for the Fluke 116.
How the Fluke 116 HVAC True-RMS Multimeter works
For HVAC work the 116 combines three things on one dial: temperature through a K-type thermocouple input, microamp current for flame rectification circuits, and a Lo-Z capacitance function for motor-run capacitors. A technician can therefore measure supply and return temperature, check a flame sensor and test a capacitor without changing instruments.
The large white LED backlight is useful in dark plant rooms and ceiling voids. The holster has probe holders and the meter fits an optional magnetic hanger, so it can be hung from a unit panel while both hands are free.
Key features
- Built-in temperature measurement with included probe
- Microamp ranges for flame sensors
- Lo-Z capacitance for run capacitors
- Min/Max/Average recording
- Holster with probe holders and silicone leads
Where 116 fits and related Fluke models
The 116 is the HVAC variant of the 110 series. The 114 is the simple go/no-go model, the 115 is the general field meter and the 117 adds non-contact voltage detection. Choose the 116 whenever temperature or flame-sensor current matters.
For clamp-style HVAC testing, a wireless clamp such as the 902 FC covers current to 600 A together with temperature.
Selection checklist for 116
Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.
- Temperature range of interest within -40 °C to 400 °C.
- Need for microamp measurement for flame sensors.
- CAT III 600 V rating suits equipment panels but not service-entrance locations.
- Probe style: the included 80BK is a general-purpose bead probe.
Safe use, care and maintenance of 116
- Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 116 touches any live circuit.
- Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
- Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 116 HVAC True-RMS Multimeter.
- Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
- Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.
Typical applications of 116 in Oman and the GCC
Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.
In Oman the 116 is used by building services and chiller maintenance teams in malls, hospitals, hotels, airports and industrial campuses, where air-conditioning loads are very high during summer. Quick temperature and capacitor checks help restore cooling equipment with minimal downtime.
116 compared with nearby models
| Model | Temperature | Microamps | Non-contact voltage |
|---|---|---|---|
| 114 | No | No | No |
| 115 | No | No | No |
| 116 | Yes | Yes | No |
| 117 (not covered here) | See datasheet | See datasheet | Yes |
Only functions stated by the manufacturer for the 114, 115 and 116 are shown for those models.
Information to send with an RFQ for 116
To prepare an accurate quotation, please send:
- Exact model 116 and the quantity required.
- Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
- Required test lead type and any extra clips or probes.
- Temperature probe, case or magnetic hanger requirements.
- Whether calibration traceability paperwork is needed on delivery.
- Delivery point in Oman or elsewhere in the GCC and the required date.
Storage, handling and spares for the Fluke 116
Store the Fluke 116 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.
- Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
- Use only leads and accessories rated for the same or a higher measurement category than the work you do.
- Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
- Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.
If your team uses several units of the Fluke 116, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.
Documents and quotation
A manufacturer datasheet for the Fluke 116 HVAC True-RMS Multimeter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.
For a quotation, send the part number 116, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.
Other Models in the Fluke 110 Series Dmm Range
Seven Star LLC supplies models from the Fluke 110 Series Dmm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Fluke 115 True-RMS Field Technician Digital Multimeter | Electrical Testers & Multimeters | View details |
| Fluke 116 HVAC True-RMS Multimeter with Temperature and uA | Electrical Testers & Multimeters | You are viewing this model |
| Fluke 114 True-RMS Electrical Multimeter with AutoVolt | Electrical Testers & Multimeters | View details |
| Fluke 113 Utility Digital Multimeter with VCHEK LoZ | Electrical Testers & Multimeters | View details |
Datasheets & Documents
- Datasheet Fluke 116 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 116 HVAC True-RMS Multimeter with Temperature
Answers from our engineering team on installation, compatibility and integration.
01What temperature range does the Fluke 116 cover?
It measures -40 °C to 400 °C with a Type-K thermocouple, accuracy 1% + 10 counts excluding the probe error.
02Why does an HVAC meter need microamps?
Flame rectification sensors in gas burners produce currents in the microamp range. The 116 has 600 µA AC and DC ranges to test them.
03Does the 116 include a temperature probe?
Yes, the manufacturer lists an 80BK temperature probe among the contents, together with silicone test leads and a holster.
04Can the 116 test motor capacitors?
Yes, it measures capacitance up to 9999 µF and has a Lo-Z capacitance function for 1 nF to 500 µF.
05What is the safety rating of the 116?
It is rated CAT III 600 V under IEC 61010-2-033 and is independently tested for that environment.


















Reviews