Fluke 179 True-RMS Digital Multimeter with Temperature

Description

179 true-RMS multimeter with built-in temperature explained

The Fluke 179 True-RMS Digital Multimeter (179) is a handheld true-RMS digital multimeter of the Fluke 170 series. It is the top model of that series because it adds contact temperature measurement to the voltage, current, resistance, capacitance and frequency functions of its siblings. Seven Star LLC supplies 179 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The model number is short, so the table below sets out what the identifiers mean when you compare it with the 175 and 177 in the same family.

Element Value Meaning
179 Model Top model of the 170 series, with temperature
True-RMS Measurement method Correct readings on non-sinusoidal waveforms such as drive outputs
CAT III 1000 V / CAT IV 600 V Overvoltage category Protection level for distribution and service-entrance work
80BK probe included Temperature accessory K-type bead probe supplied in the box

179 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 179
DC voltage Up to 1000 V, best accuracy ±(0.09% + 2), resolution 0.1 mV
AC voltage (true-RMS) Up to 1000 V, best accuracy ±(1.0% + 3)
DC current Up to 10 A, best accuracy ±(1.0% + 3)
AC current (true-RMS) Up to 10 A, best accuracy ±(1.5% + 3)
Resistance Up to 50 MΩ, best accuracy ±(0.9% + 1)
Capacitance Up to 10,000 µF, best accuracy ±(1.2% + 2)
Frequency Up to 100 kHz, best accuracy ±(0.1% + 1)
Temperature -40 °C to 400 °C, best accuracy ±(1.0% + 10), excluding probe
Safety rating EN 61010-1: 1000 V CAT III, 600 V CAT IV
Operating temperature -10 °C to +50 °C
Size / weight 43 x 90 x 185 mm / 420 g
Battery 9 V alkaline, about 200 hours typical without backlight
Warranty Lifetime

Values are taken from the manufacturer product page for the Fluke 179. Accuracy figures are the best accuracy for each function.

How the Fluke 179 True-RMS Digital Multimeter works

The 179 converts every input into a digital value with a 6000-count display and shows a bar graph beside it, so a fast-changing signal can still be followed even when the digits are moving. True-RMS conversion means the instrument calculates the heating value of the waveform instead of assuming a pure sine wave. This matters on supply lines that feed variable-speed drives, switch-mode power supplies and lighting ballasts, where an average-responding meter reads low.

For temperature the meter takes a K-type thermocouple input and applies cold-junction compensation internally, so a bearing housing, a terminal lug or a cable gland can be checked without a second instrument. Display Hold and Auto Hold freeze a stable reading so that it can be recorded when the display is out of view, and Min/Max/Average recording captures drift or an intermittent supply dip while you do something else.

Key features

  • Manual and automatic ranging with Display Hold and Auto Hold
  • Min/Max/Average recording for intermittent faults
  • Backlit display with analog bar graph
  • Closed-case calibration through the front panel
  • Integrated protective holster

Where 179 fits and related Fluke models

Within the 170 series the 179 sits above the 175 and the 177. All three share the same measurement ranges for voltage, current, resistance, capacitance and frequency; the 179 is the one that also reads temperature, and it shares the 0.09% DC voltage accuracy with the 177. Choose the 179 when one tool must cover electrical faults and quick thermal checks on the same call-out.

For more demanding industrial work, such as VFD output measurements, logging or wider temperature ranges, buyers usually look at the 87V, 287 or 289 instead. For handheld work in tighter budgets the 115, 116 and 117 are compact alternatives rated to CAT III 600 V.

Selection checklist for 179

Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.

  • Voltage level of the installations: the 179 is rated CAT III 1000 V and CAT IV 600 V.
  • Need for temperature: if not needed, the 177 gives the same DC accuracy.
  • Maximum current: the direct current input is limited to 10 A, so larger currents need a clamp meter.
  • Accessories: temperature probe included; extra leads, clips and case are separate.

Safe use, care and maintenance of 179

  • Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 179 touches any live circuit.
  • Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
  • Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 179 True-RMS Digital Multimeter.
  • Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
  • Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.

Typical applications of 179 in Oman and the GCC

Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.

Typical uses include checking control-panel supplies, verifying motor-starter circuits, reading 4-20 mA loop voltage drops at a marshalling cabinet and finding an overheated terminal on a distribution board. In hot Gulf plant rooms, the temperature function helps confirm whether a connection is running warm before it fails.

179 compared with nearby models

Model DC accuracy (best) Temperature Notable difference
175 ±(0.15% + 2) Not included General-purpose baseline
177 ±(0.09% + 2) Not included Higher DC accuracy than the 175
179 ±(0.09% + 2) -40 °C to 400 °C Adds built-in temperature measurement
87V See datasheet Thermocouple range Industrial model with extended functions

The comparison is a simplified view. Always check the manufacturer datasheet for full ranges and accuracy conditions.

Information to send with an RFQ for 179

To prepare an accurate quotation, please send:

  • Exact model 179 and the quantity required.
  • Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
  • Required test lead type and any extra clips or probes.
  • Temperature probe, case or magnetic hanger requirements.
  • Whether calibration traceability paperwork is needed on delivery.
  • Delivery point in Oman or elsewhere in the GCC and the required date.

Documents and quotation

A manufacturer datasheet for the Fluke 179 True-RMS Digital Multimeter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.

For a quotation, send the part number 179, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.

Other Models in the Fluke 170 Series Dmm Range

Seven Star LLC supplies models from the Fluke 170 Series Dmm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Fluke 177 True-RMS Digital Multimeter, CAT III 1000 VElectrical Testers & MultimetersView details
Fluke 175 True-RMS Digital Multimeter, CAT III 1000 VElectrical Testers & MultimetersView details
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 179 True-RMS Digital Multimeter with

Answers from our engineering team on installation, compatibility and integration.

01What does the Fluke 179 measure that the 175 does not?
The 179 adds contact temperature measurement from -40 °C to 400 °C using the included thermocouple probe. The 175 does not measure temperature, and its best DC voltage accuracy is lower.
02Is the 179 suitable for variable-frequency drive circuits?
It reads true-RMS AC voltage and current, which is correct for non-sinusoidal waveforms. For drive outputs, check the bandwidth in the datasheet and consider a model with a low-pass filter if needed.
03What safety category is the Fluke 179 rated to?
It is rated to EN 61010-1 for 1000 V CAT III and 600 V CAT IV. This covers most distribution-level maintenance work but not every service-entrance location.
04How large a current can the 179 measure?
The direct current inputs measure up to 10 A AC or DC. For higher currents a clamp meter or a current transformer is the safer and correct choice.
05Does the 179 come with a warranty?
The manufacturer states a lifetime warranty on this model. Warranty handling for units supplied through an independent supplier should be confirmed with us at quotation.