Brand: Weidmüller
Weidmuller WTL 6/3 Measuring Transformer Disconnect Terminal
Description
Weidmuller WTL 6/3 measuring transformer disconnect terminal, order no. 1018800000
1018800000 is the Weidmuller WTL 6/3, a measuring-transformer disconnect terminal with screw connection, supplied here in the closed state with a spacer. It is used where the secondary circuit of a current or voltage transformer must be opened for testing without disturbing the transformer. The terminal is dark beige Wemid with UL 94 V-0 rating, and the datasheet lists a rated current of 41 A at 6 mm². Seven Star LLC supplies 1018800000 in Oman and the GCC as an independent supplier in Muscat.
In switchgear and protection panels the secondary side of measuring transformers needs a defined test point. A disconnect terminal lets a technician isolate a relay or meter from the transformer, insert test equipment and restore the circuit afterwards, all with a defined sequence of positions. That is the reason this terminal type appears on protection and metering cabinets rather than on ordinary signal wiring.
Reading the type WTL 6/3 and order number 1018800000
| Element | Value | Meaning |
|---|---|---|
| WTL | Series | Disconnect terminal for measuring transformer circuits |
| 6 | 6 mm² | Rated conductor cross-section |
| /3 | Version suffix | Variant designation within the 6 mm² family; the data sheet does not expand it further |
| Order no. | 1018800000 | Article number to quote |
Technical specifications for 1018800000
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Weidmuller / 1018800000 (type WTL 6/3) |
| Version | Measuring transformer disconnect terminal, screw connection, closed, with spacer, 1 level, TS 35 |
| Rated cross-section | 6 mm² |
| Rated voltage | 500 V |
| Nominal current | 41 A |
| Current at maximum wire size | 57 A |
| Contact resistance (IEC 60947-7) | 0.78 mΩ |
| Power loss (IEC 60947-7) | 1.31 W |
| Clamping range | 0.5 mm² to 10 mm² |
| Stripping length | 12 mm |
| Tightening torque | 0.8 Nm to 1.6 Nm |
| Clamping screw / blade | M 3.5 / 0.8 x 4.0 mm |
| Width | 7.9 mm |
| Height | 87 mm |
| Depth including rail | 65 mm |
| Net weight | 28.22 g |
| Rated impulse withstand voltage | 6 kV |
| Surge voltage category / pollution severity | III / 3 |
| Rated DC voltage | 500 V |
| UL rating | 45 A, 300 V (UR), conductors 20–8 AWG |
| CSA rating | 45 A, 300 V, 20–8 AWG |
Current, voltage and clamping data for 1018800000
The rated values are 41 A at 500 V with a rated cross-section of 6 mm², and the data sheet allows 57 A with the largest wire. Contact resistance is 0.78 mΩ and power loss 1.31 W, which is relevant because current-transformer circuits tolerate very little additional burden. The clamping range is 0.5 mm² to 10 mm², stripping length is 12 mm and the M 3.5 screw is tightened with 0.8 x 4.0 mm between 0.8 Nm and 1.6 Nm.
This version is a closed terminal with a spacer for a plug-in cross-connector, and it does not need an end cover plate according to the data sheet. It is not marked for hazardous-area use (the explosion-tested version entry is No), so do not use it in Ex-certified wiring.
Using WTL 6/3 in protection and metering circuits
Current transformer secondaries must never be left open while the primary carries current, because the voltage across an open secondary can rise to dangerous levels. A disconnect terminal avoids this by providing a defined way to short or bypass the circuit during work. Always follow the sequence defined by your protection design and your site safety procedure; this page does not replace that procedure.
Related terminals for 1018800000
For general power feeders, the WDU 6 (1020200000) and WDU 10 (1020300000) feed-through terminals use similar cross-sections, and for earth bonding WPE 4 (1010100000) is the matching size family. Choose 1018800000 only for transformer-secondary test points; use feed-through terminals for all other circuits.
Selection checklist for 1018800000
- Confirm the circuit is a measuring transformer secondary and the function required (current or voltage).
- Conductor size: 0.5 to 10 mm² clamping range, 6 mm² rated.
- Panel depth: 65 mm including rail and 87 mm high.
- Pack quantity: 50 pieces according to the data sheet.
- Test procedure and any test plugs required by your protection design.
Installation and maintenance of WTL 6/3
Snap onto the TS 35 rail, wire with ferruled conductors and tighten to the torque above. Label each terminal with the transformer phase and polarity, and test the isolation sequence before energising. At each annual protection test, verify that the clamping points are tight and that the disconnect position returns to the closed state.
Typical applications in Oman and the GCC
Disconnect terminals for measuring transformers are used in medium-voltage switchgear, generator protection panels, power-plant auxiliary boards and utility substations in Oman and the GCC. In these sites the terminal must remain reliable through heat cycles and dust, and technicians rely on the clear marking of the isolation positions during relay testing.
Information to send with an RFQ for 1018800000
- Exact order number 1018800000 (WTL 6/3) and the quantity, including spares or packs.
- Transformer type (current or voltage) and the number of terminals needed.
- Conductor size and circuit current.
- Test plug or cross-connector requirements.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as the datasheet or a compliance statement.
Storage, handling and spares for the Weidmuller 1018800000
Keep Weidmuller 1018800000 units in their original packaging until they are mounted. Store them indoors in a dry, dust-free room, away from direct sun and condensation. Panel shops in Oman and the GCC often hold stock in warehouses that get very hot in summer, so check that storage temperature stays within the limits given in the manufacturer datasheet.
- Check the label and order code on every unit against the drawing before it goes into the panel.
- Use the correct tool and tightening torque for the terminals, as given in the instructions supplied with the product.
- Keep a small number of spare units for each rating used on site, so that a failed or damaged part can be replaced without waiting for a new shipment.
- Record the order code in the panel documentation and the as-built drawings, so that maintenance teams can reorder the same part later.
When you plan spares for a project, group the Weidmuller 1018800000 with the other parts of the same panel in one RFQ. This keeps delivery dates aligned and makes it easier to confirm stock for the whole bill of materials at once.
Documents and quotation
The manufacturer data sheet for 1018800000 is attached on this page. It lists the ordering data, approvals, ratings and drawings, so please check its notes against your design before you order.
To request a quotation, send order number 1018800000, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we will confirm availability and lead time for your order.
Datasheets & Documents
- Datasheet Weidmüller WTL 6/3 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Weidmüller is a German family-owned maker of electrical connection and industrial electronics products, headquartered in Detmold. The company dates from 1850 and was re-established in Detmold in 1948; it specialised in terminal blocks from the 1940s onward. Weidmüller makes Klippon terminal blocks, power supplies, remote I/O and enclosures, and reported over one billion euros in revenue in 2023.
Seven Star LLC lists Weidmüller PRO MAX power supplies and SAK terminal blocks, and supplies Weidmüller components to panel shops and plants in Oman and the GCC.
Weidmüller company profile
| Founded | 1850, Germany |
|---|---|
| Headquarters | Detmold, Germany (since 1948) |
| Ownership | Family-owned |
| Revenue | Over €1 billion (2023) |
| Product families | Klippon Connect terminal blocks, PRO MAX and PRO TOP power supplies, u-remote I/O and fieldbus couplers, Klippon enclosures, connectors and tools |
Milestones
- 1850: Weidmüller is founded.
- 1948: The company is re-established in Detmold.
Weidmüller products listed here
The listed power supplies are DIN rail switch-mode units with 24 V DC output: a PRO MAX single-phase unit rated 180 W and 7.5 A (85 to 277 V AC input), and a PRO MAX3 three-phase unit rated 240 W and 10 A (320 to 575 V AC input). The SAK series is the screw clamp feed-through terminal block family found in many existing panels. Weidmüller now flags several SAK types as being phased out and names a replacement for some of them.
Weidmüller products we list
Ordering Weidmüller parts: what we need
Weidmüller identifies every item by a ten-digit order number, and that number is the surest way to quote. Without it, send the type printed on the part. For power supplies add input voltage and phases, output voltage and current. For terminal blocks add the conductor cross-section, color, and the end plates, cross-connections and markers you need, since accessories are specific to each series.
Facts checked against Weidmüller milestone lists and distributor profiles, October 2026.
Browse Weidmüller products by category: Electrical & Power Modules.
FAQ
Questions about the Weidmuller WTL 6/3 Measuring Transformer Disconnect
Answers from our engineering team on installation, compatibility and integration.
01What is 1018800000 used for?
It is the Weidmuller WTL 6/3 measuring-transformer disconnect terminal. It lets technicians open and test the secondary circuit of a current or voltage transformer without disturbing the wiring.
02What current rating does the WTL 6/3 have?
The data sheet gives 41 A nominal current at the rated 6 mm² cross-section and 57 A with the largest wire. UR and CSA entries list 45 A.
03Can I use WTL 6/3 in a hazardous area?
The data sheet lists the explosion-tested version as No, so the terminal should not be used for Ex-certified wiring. Ask us for a suitable alternative if you need one.
04Does 1018800000 need an end cover plate?
According to the data sheet, no end cover plate is required for this closed version. Check your cross-connector and spacer needs before ordering.
05How many terminals are supplied per pack?
The data sheet lists 50 pieces per pack for 1018800000. Send the number you need and we will quote accordingly.