Schneider Electric 18856 NG125L 3P 80A D-Curve MCB

Description

18856: Acti9 NG125L 3-pole 80 A D-curve miniature circuit-breaker

The 18856 is a Schneider Electric Acti9 NG125L three-pole miniature circuit-breaker rated 80 A with a D curve. The datasheet lists a breaking capacity of 50 kA Icu at 380–415 V AC and 100 kA at 220–240 V AC, thermal-magnetic tripping and clip-on mounting on a 35 mm DIN rail. Seven Star LLC supplies it as an independent supplier in Oman and the GCC for switchboard builders, electrical contractors and maintenance teams.

The title of the reference reads NG125 – circuit breaker – NG125L – 3P – 80A – D curve, which is the only decoding available: NG125L is the high-breaking-capacity version in the family, 3P the number of poles, 80 A the rating and D the tripping curve. The datasheet we downloaded is dated 8 Nov 2026 and carries a notice that the product was discontinued on 20 Oct 2026, with end-of-service planned for 30 Apr 2030.

Technical specifications of the 18856

Parameter Specification
Manufacturer / part number Schneider Electric / 18856
Range Acti9
Product name Acti9 NG125
Device short name NG125L
Product type Miniature circuit-breaker
Application Distribution
Poles 3P (3 protected poles)
Rated current [In] 80 A at 40 °C
Network type AC; DC
Trip unit Thermal-magnetic
Curve code D
Magnetic tripping limit 12 x In ± 20 %
Breaking capacity [Icu] 100 kA at 220–240 V AC; 50 kA at 380–415 V AC; 40 kA at 440 V AC; 15 kA at 500 V AC; 36 kA at ≤ 375 V DC (EN/IEC 60947-2)
Service breaking capacity [Ics] 75 kA (75 %) at 220–240 V AC; 37.5 kA (75 %) at 380–415 V AC; 30 kA (75 %) at 440 V AC; 11.25 kA (75 %) at 500 V AC; 50 kA (100 %) at 375 V DC
Utilisation category Category A (IEC 60947-2)
Suitability for isolation Yes (IEC 60947-2)
Rated insulation voltage [Ui] 690 V AC
Rated impulse withstand [Uimp] 8 kV
Mounting Clip-on, 35 mm DIN rail, vertical
Width 81 mm (9 pitches of 9 mm)
Height x depth 103 × 81 mm
Net weight 0.72 kg
Terminals Tunnel type: 16–70 mm² rigid; 10–50 mm² flexible; strip length 20 mm; torque 6 N.m
Durability Mechanical 20000 cycles; electrical 5000 cycles
Padlocking Integrated, padlockable
Earth-leakage protection Separate block
IP / IK IP20 / IK05
Pollution degree / overvoltage category 3 / IV
Ambient temperature -30–70 °C operation; -40–70 °C storage
Humidity / altitude 95 % at 55 °C; 2000 m
Tropicalisation Level 2 (IEC 60068-1)
Standard EN/IEC 60947-2

Breaking capacity and system voltages for the 18856

Breaking capacity depends on the system voltage. The datasheet lists 100 kA at 220–240 V AC, 50 kA at 380–415 V AC, 40 kA at 440 V AC and 15 kA at 500 V AC, all to EN/IEC 60947-2. For DC it gives 36 kA at up to 375 V DC. The service breaking capacity (Ics) is 75 % of Icu on the AC values and 100 % on the DC value, so the breaker stays serviceable after a fault at those levels.

Compare the prospective short-circuit current at the point of installation with the figure for the voltage that applies, not the highest number in the table. On a 415 V three-phase system the relevant value is 50 kA, and the board design must also respect the busbar and enclosure ratings.

Selection checklist for the 18856

  • Rating and poles: 80 A, 3P, to match the cable and the load.
  • Curve: D, for high inrush loads; confirm against the load data.
  • Breaking capacity: compare the fault level at the board with the Icu for your voltage.
  • Network: AC or DC use, with the DC voltage limit of 375 V.
  • Earth-leakage protection: a separate block is required if wanted.
  • Lifecycle: discontinued notice on the datasheet; plan spares.

Typical uses of the 18856 in Oman and the GCC

NG125 breakers are used as feeder and main protection in distribution boards for commercial buildings, workshops, utilities and light industrial plant. The L version suits locations close to transformers, where fault levels are high, and sites with generator or DC supplies within the voltage limits listed.

In the region, large air-conditioning loads, pumps and motor circuits with high starting current are typical D-curve users. Thermographic inspection of the terminals during the summer peak is a cheap way to catch a loose termination before it fails.

Mounting, terminals and handling of the 18856

The breaker clips onto a 35 mm symmetrical DIN rail in a vertical position. It is 81 mm wide, which corresponds to nine 9 mm pitches, 103 mm high and 81 mm deep, and weighs 0.72 kg. The datasheet states that comb busbar and distribution block compatibility is not provided, so wiring is by cable into the terminals.

Tunnel terminals accept 16–70 mm² rigid or 10–50 mm² flexible conductors with a 20 mm strip length and a 6 N.m tightening torque. Use a calibrated torque screwdriver; loose terminals at this current level are a common source of heating. Integrated padlocking allows the breaker to be locked in the open position for isolation work.

Lifecycle status and spares planning for the 18856

Because the datasheet marks the 18856 as discontinued, planning matters. For an installed base, the practical steps are to count the breakers in service, buy spares while stock is available and ask us about a replacement series for new work. Mechanical durability is listed as 20000 cycles and electrical durability as 5000 cycles, which gives a basis for maintenance planning on frequently operated circuits.

The datasheet date of 8 Nov 2026 is the date of the downloaded document, and we have not checked it against later manufacturer notices. Send us the reference and we will confirm what is available for your quantity.

D curve and tripping behaviour of the 18856

The thermal-magnetic trip unit combines a bimetal element for overloads with a magnetic element for short circuits. The datasheet gives the magnetic tripping limit as 12 × In ± 20 %, which on an 80 A breaker corresponds to a threshold of about 960 A, with a tolerance band of roughly 770 to 1150 A. That is the figure to use in selectivity and cable-protection studies.

A D curve tolerates high inrush current, so it suits loads such as transformers, motors with large starting current and capacitive equipment. For ordinary resistive and mixed distribution circuits, a C curve is more common, and the choice should follow the load and the earth-fault loop impedance, not habit.

Information to send with an RFQ for the 18856

  • Exact reference 18856 and quantity.
  • System voltage, frequency and AC or DC use.
  • Prospective fault level at the board.
  • Existing breaker make and model if this is a replacement.
  • Delivery location and project schedule.

Documents and quotation

The manufacturer datasheet for the 18856 is attached on this page and carries the specification summarised above. It also states the discontinuation notice described above. Check the revision date printed on it against your project documents before you rely on a figure.

Send us the reference 18856, the quantity and the delivery location, and Seven Star LLC will reply to your request. We are an independent supplier based in Muscat and we confirm availability and lead time per enquiry.

Datasheets & Documents
  • PDF Datasheet Schneider Electric 18856 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric 18856 NG125L 3P 80A D-Curve MCB

Answers from our engineering team on installation, compatibility and integration.

01What is the rating and curve of the 18856?
The datasheet lists 80 A at 40 degrees C, three poles, thermal-magnetic trip and a D curve.
02What breaking capacity does the 18856 have?
It is listed at 100 kA Icu at 220-240 V AC, 50 kA at 380-415 V AC, 40 kA at 440 V AC, 15 kA at 500 V AC and 36 kA at up to 375 V DC.
03When does the 18856 trip magnetically?
The datasheet gives a magnetic tripping limit of 12 x In, plus or minus 20 %.
04How is the 18856 mounted and terminated?
It clips onto a 35 mm DIN rail and uses tunnel terminals for 16-70 mm2 rigid or 10-50 mm2 flexible conductors, with a 6 N.m tightening torque.
05Is the 18856 still current?
The datasheet we downloaded, dated 8 Nov 2026, carries a discontinuation notice of 20 Oct 2026 and planned end-of-service on 30 Apr 2030. Ask us about replacements for new work.