Brand: Schneider Electric
Schneider Electric TM241CE24T Modicon M241 24 I/O Ethernet PLC
Description
TM241CE24T: Modicon M241 24-I/O controller with Ethernet, source outputs
The TM241CE24T is a Modicon M241 logic controller with 24 built-in I/O points and an integrated 10/100 Ethernet port. It has fourteen 24 V DC inputs, ten transistor source outputs, fast counting and pulse functions, two serial ports and USB, so it combines machine-level speed with plant-network connectivity.
What sets this unit apart from the basic TM241C24T is the long list of Ethernet services in the datasheet, which includes Modbus TCP, EtherNet/IP, OPC UA server, a web server, FTP, SQL and e-mail functions. The sink-output twin is TM241CE24U. Seven Star LLC supplies the this unit in Oman and the GCC as an independent supplier in Muscat.
Where the TM241CE24T is used
Machine builders and skid packagers in Oman and the GCC use this class of controller for bottling, packaging, material handling and process skids that report to a SCADA over Ethernet. Because the datasheet lists the Modbus TCP and EtherNet/IP services, it connects to a wide range of drives, instruments and HMIs on the same switch.
Operating range is −10 to 55 °C horizontal and −10 to 50 °C vertical, with approvals cULus, CE, UKCA, RCM, DNV-GL, ABS and LR.
Technical specifications of the TM241CE24T
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / TM241CE24T |
| Range of product | Modicon M241 |
| Product type | Logic controller |
| Rated supply voltage | 24 V DC, limits 20.4–28.8 V; inrush 50 A |
| Power consumption | 32.6–40.4 W with maximum expansion |
| Discrete inputs | 14 at 24 V DC, 8 of them fast; sink or source |
| Discrete outputs | 10 transistor, 24 V DC, 0.5 A, positive logic (source); 4 fast outputs |
| Fast input counting | 4 fast inputs (HSC) up to 200 kHz; A/B at 100 kHz |
| Pulse outputs | PTO on 4 channels at 100 kHz; PWM up to 20 kHz |
| Expansion | 7 local or 14 remote TM3 modules |
| Memory | 64 MB system RAM; 128 MB flash for user programs |
| Removable storage | SD card up to 16 GB (optional) |
| Real-time clock | Built in; drift 60 s/month or less at 25 °C |
| Battery | BR2032 lithium, 4 years life, 2 years backup at 25 °C |
| Serial and USB | Serial 1 RJ45 RS232/RS485; serial 2 screw terminal RS485; mini-B USB |
| Ethernet | 1 port 10BASE-T/100BASE-TX (10/100 Mbit/s) |
| Mounting | 35 mm DIN rail (TH35-15, TH35-7.5) or panel with kit |
| Dimensions (W x H x D) | 150 x 90 x 95 mm |
| Net weight | 0.53 kg |
| Operating temperature | −10 to 55 °C horizontal; −10 to 50 °C vertical |
| Storage temperature | −25 to 70 °C |
| Humidity | 10–95 % without condensation |
| Protection | IP20 with protective cover in place |
| Shock resistance | 15 gn for 11 ms |
| Certifications listed | cULus, CE, UKCA, RCM, DNV-GL, ABS, LR |
Choosing the TM241CE24T and preparing an RFQ
Points worth confirming:
- the output logic: source for TM241CE24T and sink for TM241CE24U
- the number of simultaneous Ethernet connections needed
- whether OPC UA or web-server features are part of the design
- pulse axes and fast counters needed on the fast I/O
- 24 V supply sizing for the 50 A inrush
Add quantity, destination and programming software version to your enquiry.
The TM241CE24T in the M241 24-point group
| Reference | Ethernet port | 24 V outputs | Ports |
|---|---|---|---|
| TM241C24T | No | Transistor source | Serial x2, USB |
| TM241CE24T | Yes, 10/100 | Transistor source | Serial x2, USB, Ethernet |
| TM241CE24U | Yes, 10/100 | Transistor sink | Serial x2, USB, Ethernet |
Wiring and mounting the TM241CE24T
The case measures 150 × 90 × 95 mm and weighs 0.53 kg, fixed on a TH35-15 or TH35-7.5 rail or on a panel with the kit. Inputs, outputs and the supply connect to removable screw terminal blocks at 5.08 mm pitch. Inrush current is 50 A.
Maximum cable lengths are 50 m unshielded for standard inputs and outputs, 10 m shielded for fast inputs and 3 m shielded for fast outputs. Run Ethernet in a separate route from power wiring, and use shielded patch cords inside the cabinet near drives.
Network services of the TM241CE24T
The Ethernet port is 10BASE-T/100BASE-TX. The datasheet lists services for programming, downloading, monitoring and firmware update, plus Modbus TCP client I/O scanner, EtherNet/IP originator I/O scanner, EtherNet/IP target, Modbus TCP server and slave, OPC UA server, web server (WebVisu and XWeb), SNMP client and server, FTP client and server, SQL client, DNS and DHCP client, SMS notification and e-mail send/receive through the TCP/UDP library.
This is a broad feature set for a machine controller. It lets one unit act as a data gateway, send alarm mails, publish values to OPC UA and serve a browser page without extra hardware.
Inputs, outputs and fast functions of the TM241CE24T
Fourteen inputs at 24 V DC are fitted, with eight of them fast inputs that respond in 2 µs or less. Four fast inputs can count at up to 200 kHz in single-phase or pulse/direction mode, or at 100 kHz in A/B mode, while the other fourteen inputs count at 1 kHz. Filtering can be set between 0 and 12 ms on standard inputs.
Of the ten transistor outputs, Q0 to Q3 are fast outputs that can generate PTO pulses at 100 kHz on four channels, PWM up to 20 kHz or pulse output at 100 kHz, while Q4 to Q9 switch at 1 kHz. Output current per point is 0.5 A (0.1 A for fast outputs in PTO mode), the outputs are protected against short circuit, and a fast output resets after 12 s.
Connection limits and cycle time on the TM241CE24T
The datasheet gives maximum connection counts: 8 Modbus server, 8 SoMachine protocol, 10 web server, 4 FTP server, 16 EtherNet/IP target and 8 Modbus client. As a client it can serve 64 Modbus TCP devices or 16 EtherNet/IP devices, with cycle times of 64 ms and 10 ms respectively.
Use these figures to size an I/O network. If many remote drives or I/O blocks are to be scanned at short intervals, count the devices and check them against the 16 EtherNet/IP and 64 Modbus TCP limits.
Documents and quotation
The Schneider Electric datasheet for the this unit is attached on this page, so you can compare the listed values with your design before ordering.
To request a quotation for the TM241CE24T, send the quantity, delivery destination and any project reference through the RFQ form. Seven Star LLC supplies Schneider Electric automation products in Oman and the GCC as an independent supplier based in Muscat, and we confirm stock status and lead time against your request.
Other Models in the Se M241 24io Range
Seven Star LLC supplies models from the Se M241 24io range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric TM241C24T Modicon M241 24 I/O Controller | Logic Controllers | View details |
| Schneider Electric TM241CE24T Modicon M241 24 I/O Ethernet PLC | Logic Controllers | You are viewing this model |
| Schneider Electric TM241CE24U M241 24 I/O Sink Ethernet PLC | Logic Controllers | View details |
Datasheets & Documents
- Datasheet Schneider Electric TM241CE24T Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric TM241CE24T Modicon M241 24 I/O
Answers from our engineering team on installation, compatibility and integration.
01What Ethernet port does the TM241CE24T have?
One 10BASE-T/100BASE-TX port at 10/100 Mbit/s, with Modbus TCP, EtherNet/IP, OPC UA server, web server, FTP, SNMP, SQL and e-mail services listed in the datasheet.
02What output type does the TM241CE24T use?
Ten transistor outputs at 24 V DC and 0.5 A in positive logic (source). Four are fast outputs. TM241CE24U is the sink version.
03How many Modbus TCP devices can the TM241CE24T serve?
The datasheet lists 64 Modbus TCP servers and 16 EtherNet/IP devices, with cycle times of 64 ms and 10 ms.
04What memory does the TM241CE24T have?
64 MB of system RAM, 128 MB of flash for user programs and an optional SD card up to 16 GB.
05What is the inrush current of the TM241CE24T?
50 A at a supply of 24 V DC (20.4 to 28.8 V), so size the supply accordingly.