Schneider Electric TM3DQ16RG Modicon TM3 16 Relay Output Module

Description

TM3DQ16RG: TM3 16-channel relay output module with spring terminals

The TM3DQ16RG is a Modicon TM3 output module with sixteen normally open relay outputs rated 2 A, in a case 27.4 mm wide. It is the high-density relay option for Modicon M221, M241, M251 and M262 controllers, and the spring terminals make the field wiring faster and keep it tight in panels that heat and cool daily.

Eight-channel alternatives are TM3DQ8R with screw terminals and TM3DQ8RG with spring terminals; the combined 16 input and 8 output module is TM3DM24RG. Choose the this unit when you need many isolated switching points per slot. Seven Star LLC supplies the this unit in Oman and the GCC as an independent supplier based in Muscat.

Power draw and reliability of the TM3DQ16RG

The module takes 37 mA at 5 V DC from the expansion bus, plus a small additional current listed in the datasheet, and does not need a separate 24 V supply for its own operation. A green LED per channel shows each output state. The MTBF is quoted at 130 years at 40 °C.

Because relays have limited electrical life, the module is best used for slow switching: motor starter coils, valve solenoids, alarm beacons and interposing relays, not for pulse or PWM duties.

Relay data for the TM3DQ16RG

The sixteen relays are normally open and rated 2 A, switching 240 V AC or 30 V DC. Minimum switching current is 10 mA at 5 V DC, response time is 10 ms to switch on and 5 ms to switch off, and mechanical durability is 20 million cycles. Channels are isolated from the bus at 500 V AC.

Mixed voltages (for example 230 V AC and 24 V DC loads) are possible on the same module if the groups are separated by the wiring, but keep the circuits physically apart in the cabinet and follow the voltage-separation rules of your standard.

Technical specifications of the TM3DQ16RG

Parameter Specification
Manufacturer / part number Schneider Electric / TM3DQ16RG
Range of product Modicon TM3
Product type Discrete output module
Discrete outputs 16 relay, normally open; 240 V AC or 30 V DC
Relay current 2 A (2000 mA)
Minimum switching current 10 mA at 5 V DC
Output response 10 ms maximum turn-on; 5 ms maximum turn-off
Mechanical durability 20 million cycles
Reliability MTBF 130 years at 40 °C
Isolation 500 V AC between channels and bus
Bus consumption 37 mA at 5 V DC
Terminals (datasheet text) 10 x 1.5 mm² removable spring, pitch 3.81 mm; 0.14–1.5 mm² (26–16 AWG)
Cable length Unshielded, 30 m maximum
Dimensions (W x H x D) 27.4 x 90 x 84.6 mm
Net weight 0.145 kg
Compatible controllers Modicon M221, M241, M251, M262
Mounting 35 mm DIN rail (TH35-15, TH35-7.5) or panel with fixing kit
Operating temperature −10 to 55 °C horizontal; −10 to 35 °C vertical
Storage temperature −25 to 70 °C
Humidity 10–95 % without condensation
Protection IP20
Certifications listed CE, cULus, UKCA, RCM, EAC, cULus HazLoc
Shock / vibration 15 gn for 11 ms; 3.5 mm at 5–8.4 Hz and 3 gn at 8.4–150 Hz

Mounting and environmental limits of the TM3DQ16RG

The case is 27.4 × 90 × 84.6 mm and weighs 0.145 kg. It fits a 35 mm DIN rail or a panel with the kit. Operating temperature is −10 to 55 °C horizontal and −10 to 35 °C vertical, storage is −25 to 70 °C, humidity is 10 to 95 % without condensation and protection is IP20.

Vibration withstand is 3.5 mm at 5–8.4 Hz and 3 gn at 8.4–150 Hz, and shock withstand is 15 gn for 11 ms.

Selection checklist and RFQ details for the TM3DQ16RG

Confirm before ordering:

  • sixteen relay outputs are needed
  • load voltage and current fit 240 V AC or 30 V DC at 2 A
  • suppressors are planned for inductive loads
  • spring terminals suit the conductors in use

Send quantity, controller type and delivery site with the RFQ.

Terminals and cabling of the TM3DQ16RG

The datasheet lists a ten-terminal removable spring block of 1.5 mm² at 3.81 mm pitch for the outputs and a conductor range of 0.14 to 1.5 mm² (26 to 16 AWG). Unshielded cables up to 30 m are acceptable for the relay outputs.

Count the terminals against your wiring plan before ordering, because sixteen relay contacts need a lot of connections. Check the terminal arrangement in the attached datasheet and plan commons accordingly.

The TM3DQ16RG in the TM3 relay group

Reference Channels Terminals Width
TM3DM24RG 16 in + 8 relay Spring, 17 + 11 x 1.5 mm² 42.9 mm
TM3DM8R 4 in + 4 relay 11 x 2.5 mm² screw 27.4 mm
TM3DQ16RG 16 relay Spring, 10 x 1.5 mm² 27.4 mm
TM3DQ8R 8 relay 11 x 2.5 mm² screw 27.4 mm
TM3DQ8RG 8 relay 11 x 2.5 mm² (datasheet text) 27.4 mm

Typical uses of the TM3DQ16RG in Gulf plants

Sixteen relay outputs are valuable in pump stations with many starters, ventilation systems with fan banks, lighting control and alarm annunciation. Using a single module instead of two eight-point ones saves a slot and halves the bus connections, which matters when a controller has limited expansion capacity.

Certifications listed are CE, cULus, UKCA, RCM, EAC and cULus HazLoc.

Storage, handling and spares for the TM3DQ16RG

Keep the TM3DQ16RG in its original packaging in a dry, dust-free store until installation, and check the label against the order before fitting. For plants that run continuously, holding one spare unit on site shortens downtime if a replacement is needed during a shutdown or after a fault. Record the reference and installation date in the maintenance log so the next order can be placed quickly.

Documents and quotation

The Schneider Electric datasheet for the this unit is attached on this page, so you can compare the listed values with your design before ordering.

To request a quotation for the TM3DQ16RG, send the quantity, delivery destination and any project reference through the RFQ form. Seven Star LLC supplies Schneider Electric automation products in Oman and the GCC as an independent supplier based in Muscat, and we confirm stock status and lead time against your request.

Other Models in the Se Tm3 Relay Range

Seven Star LLC supplies models from the Se Tm3 Relay range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric TM3DM24RG Modicon TM3 16DI/8RO ModuleLogic ControllersView details
Schneider Electric TM3DM8R Modicon TM3 4DI/4RO ModuleLogic ControllersView details
Schneider Electric TM3DQ16RG Modicon TM3 16 Relay Output ModuleLogic ControllersYou are viewing this model
Schneider Electric TM3DQ8R Modicon TM3 8 Relay Output ModuleLogic ControllersView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric TM3DQ16RG Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric TM3DQ16RG Modicon TM3 16 Relay

Answers from our engineering team on installation, compatibility and integration.

01How many outputs does the TM3DQ16RG have?
Sixteen normally open relay outputs rated 2 A, switching 240 V AC or 30 V DC.
02What is the relay response of the TM3DQ16RG?
10 ms maximum to switch on and 5 ms maximum to switch off.
03What isolation does the TM3DQ16RG offer?
500 V AC between the channels and the bus.
04What is the weight of the TM3DQ16RG?
0.145 kg, in a case 27.4 mm wide, 90 mm high and 84.6 mm deep.
05How much bus current does the TM3DQ16RG use?
37 mA at 5 V DC from the expansion bus. See the datasheet linked on this page for the full figures.