- Automation & ControlView all 2,896 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric TM172PDG18R Modicon M172 18 I/O Controller
Description
TM172PDG18R: Modicon M172 programmable controller, 18 I/O
The TM172PDG18R is a Schneider Electric Modicon M171/M172 programmable controller (with display, for HVAC) with 18 I/O. This 18 I/O controller adds a backlit 128 × 64 display to the same I/O as the blind 18 I/O unit, so setpoints and alarms can be read at the panel. It weighs 0.225 kg against 0.2 kg for the blind version. This unit is supplied from 24 V ±10 % AC or 20–38 V DC, so the first thing to confirm is the control supply of the panel. Seven Star LLC supplies the TM172PDG18R in Oman and the GCC as an independent supplier based in Muscat.
The datasheet confirms the variant as programmable, with a built-in real-time clock, a display and the communication ports listed in the specifications below. Reading the reference, TM172 identifies the M172 family and PDG the blind or display body style, but this is our interpretation and not a published ordering table.
Installation and maintenance of the TM172PDG18R
Mount the unit (DIN rail or panel with accessory) in a clean cabinet and keep low-voltage signal wiring away from relay-output cabling. Check that the supply is 24 V ±10 % AC or 20–38 V DC before energising, since the 48 V DC and 24 V ranges differ between family members. Commission outputs with loads disconnected, then enable each channel in turn, and record the final configuration so that a spare unit can be configured in the same way.
Probe lines should be screened where lengths are long, and the sensor-supply capability (listed in the specifications) must not be exceeded. During maintenance, check terminal tightness, cabinet temperature and dust, and keep the controller programme and parameters backed up. A new TM172PDG18R on the shelf is the fastest recovery if the panel runs a critical HVAC or pumping duty.
Selection checklist for the TM172PDG18R
- Confirm the supply: 24 V ±10 % AC or 20–38 V DC.
- Count channels by type: 2 discrete inputs, 6 relay outputs: 1 SPDT, 2 SPST on a common, 3 SPST independent; 3 A relays, 8 analogue inputs.
- Check that the relay ratings cover the load.
- Confirm that Ethernet, BACnet IP and Modbus TCP are required; they are present here.
- Check the width of the housing (72 mm) against the panel layout.
Technical specifications of the TM172PDG18R
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / TM172PDG18R |
| Range | Modicon M171/M172 |
| Product type | Programmable controller with display (HVAC) |
| Total I/O | 18 |
| Discrete inputs | 2 (sink or source, up to 2 kHz, 24 V AC/DC, 5 mA) |
| Relay outputs | 6 relay outputs: 1 SPDT, 2 SPST on a common, 3 SPST independent; 3 A |
| Analogue inputs | 8 (configurable by pair) |
| Analogue outputs | 2 (4–20 mA, 0–10 V or 2 kHz PWM) |
| Communication ports | CAN, USB A, USB mini-B, 2 × RS485 (Modbus serial or BACnet MS/TP), Ethernet RJ45 (Modbus TCP, BACnet IP, web server) |
| Display | Backlit LCD, 128 × 64 pixels |
| Real-time clock | Built-in, drift ≤ 30 s/month at −20 to 60 °C |
| Rated supply | 24 V ±10 % AC or 20–38 V DC |
| Power consumption | 11 W at 24 V AC/DC |
| Sensor supply from the unit | 5 V DC at 40 mA and 24 V DC at 100 mA |
| Mounting | DIN rail or panel with accessory |
| Dimensions (W × H × D) | 72 mm × 110 mm × 60.5 mm |
| Net weight | 0.225 kg |
| Operating temperature | −20 to 60 °C |
| Storage temperature | −30 to 70 °C |
| Relative humidity | 5–95 % non-condensing |
| Protection | IP20 |
| Warranty | 18 months |
| Certifications listed | CSA, RCM, cURus, CE, EAC |
Typical uses of the TM172PDG18R in Oman and the GCC
In the Gulf, cooling load dominates building and plant energy use, which is why HVAC controllers of this class are common. This unit fits district-cooling sub-station controls, cooling-tower and heat-recovery sequences and pressurisation and ventilation of plant rooms. Ethernet-capable controllers such as this one can report to a building-management system. Facilities contractors, OEM panel builders and utility service teams specify this family for packaged plant and retrofit work.
How the TM172PDG18R compares with related Modicon M171/M172 references
The nearest relatives of the TM172PDG18R from the datasheets we have read are listed below. Controllers and expansion modules share the housing family but differ in channels, display and Ethernet.
| Reference | Role | I/O | Display | Ethernet | Weight |
|---|---|---|---|---|---|
| TM172PBG18R | Controller | 18 | None (blind) | Yes | 0.2 kg |
| TM171PDM27R | Controller | 27 | LCD, 128 × 64 pixels | No | 0.32 kg |
| TM172PBG28R | Controller | 28 | None (blind) | Yes | 0.3 kg |
| TM172PDG07R | Controller | 7 | Backlit LCD, 128 × 64 pixels | Yes | 0.2 kg |
| TM172PDG28R | Controller | 28 | Backlit LCD, 128 × 64 pixels | Yes | 0.3 kg |
Inputs, outputs and communications of the TM172PDG18R
The discrete inputs are 2 (sink or source, up to 2 kHz, 24 V AC/DC, 5 mA). The analogue inputs are 8 (configurable by pair), and each input can be set for NTC temperature probes (NK103 Beta 3977 from −40 to 137 °C, 103AT-2 Beta 3435 from −50 to 110 °C), 0–10 V, 0–5 V (absolute or ratiometric), 0–20 mA or 4–20 mA, resistance ranges, PTC probes and Pt 1000, or as a dry-contact input. Stated accuracy is ±1 % of full scale ±1 digit on 0–10 V, 0–5 V and 4–20 mA, and ±1 °C for the NK103 NTC between −40 and 110 °C.
Outputs: 6 relay outputs: 1 SPDT, 2 SPST on a common, 3 SPST independent; 3 A. Analogue outputs: 2 (4–20 mA, 0–10 V or 2 kHz PWM). The unit can power sensors directly with 5 V DC at 40 mA and 24 V DC at 100 mA. As relays, the outputs suit contactor coils, valve actuators and signalling, and they are not intended for fast switching; use an analogue or open-collector output where the datasheet provides one for modulating duties.
Communications
The datasheet lists these ports: CAN, USB A, USB mini-B, 2 × RS485 (Modbus serial or BACnet MS/TP), Ethernet RJ45 (Modbus TCP, BACnet IP, web server). Ethernet allows Modbus TCP and BACnet IP together with a built-in web server, and each RS485 port can serve either Modbus serial or BACnet MS/TP, which makes the unit easy to place inside a building-management network.
Supply, size and environment
Supply is 24 V ±10 % AC or 20–38 V DC, with a consumption of 11 W at 24 V AC/DC. The housing is 72 mm wide, 110 mm high and 60.5 mm deep, weighing 0.225 kg; mounting is DIN rail or panel with accessory. Storage temperature is −30 to 70 °C and humidity 5–95 % non-condensing; protection is IP20, so the unit belongs inside a cabinet. Operating range is −20 to 60 °C.
In Oman and the wider Gulf, a controller panel on a plant roof or in a plant room routinely meets temperatures above the upper limits. Plan cabinet ventilation or cooling, and where the datasheet specifies derating, apply it to the actual cabinet air temperature rather than the room temperature.
Information to send with an RFQ for the TM172PDG18R
- Exact reference TM172PDG18R and quantity.
- Control supply voltage available in the panel.
- Channel count by type and the communication protocol required.
- Load types on the relays.
- Delivery location and project deadline.
Documents and quotation
The manufacturer datasheet for the TM172PDG18R is attached on this page and includes the specification summarised above. Check the revision date against your project requirements.
Send us the reference TM172PDG18R, quantity and delivery location and Seven Star LLC will reply to your RFQ. We supply as an independent supplier based in Muscat.
Other Models in the Se Modicon M17x Range
Seven Star LLC supplies models from the Se Modicon M17x range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric TM171PDM27R Modicon M171 27 I/O Controller | Logic Controllers | View details |
| Schneider Electric TM172E12R Modicon M172 12 I/O | Logic Controllers | View details |
| Schneider Electric TM172E28R Modicon M172 28 I/O | Logic Controllers | View details |
| Schneider Electric TM172PBG18R Modicon M172 18 I/O Controller | Logic Controllers | View details |
| Schneider Electric TM172PBG28R Modicon M172 28 I/O Controller | Logic Controllers | View details |
| Schneider Electric TM172PDG07R Modicon M172 7 I/O Controller | Logic Controllers | View details |
| Schneider Electric TM172PDG18R Modicon M172 18 I/O Controller | Logic Controllers | You are viewing this model |
| Schneider Electric TM172PDG28R Modicon M172 28 I/O Controller | Logic Controllers | View details |
Datasheets & Documents
- Datasheet Schneider Electric TM172PDG18R Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric TM172PDG18R Modicon M172 18 I/O
Answers from our engineering team on installation, compatibility and integration.
01What supply does the TM172PDG18R need?
The datasheet lists 24 V +/-10 % AC or 20-38 V DC, with a consumption of 11 W at 24 V AC/DC. Check the panel supply against this before ordering.
02How many inputs and outputs does the TM172PDG18R have?
It has 18 I/O in total: discrete inputs 2, relay outputs 6 relay outputs: 1 SPDT, 2 SPST on a common, 3 SPST independent; 3 A, analogue inputs 8.
03What communication does the TM172PDG18R offer?
Ports listed: CAN, USB A, USB mini-B, 2 x RS485 (Modbus serial or BACnet MS/TP), Ethernet RJ45 (Modbus TCP, BACnet IP, web server). Ethernet supports Modbus TCP and BACnet IP with a web server.
04Does the TM172PDG18R have a display?
Display: Backlit LCD, 128 x 64 pixels. Real-time clock: Built-in, drift <= 30 s/month at -20 to 60 degC.
05What are the dimensions and weight of the TM172PDG18R?
Width 72 mm, height 110 mm, depth 60.5 mm, net weight 0.225 kg. Protection is IP20.


















Reviews