Brand:

Pepperl+Fuchs UB2000-F42-U-V15 Ultrasonic Sensor

Description

UB2000-F42-U-V15 2 m ultrasonic sensor with 0 to 10 V output

The UB2000-F42-U-V15 is a rectangular ultrasonic sensor from Pepperl+Fuchs with a sensing range of 60 to 2000 mm and a 0 to 10 V analog output. Its F42 housing is 80 x 80 mm and about 34 mm deep, made of ABS, and the settings are taught using two membrane keys or a teach input. A selectable sound cone width lets it work close to walls and structures, with an unusually small dead band of 60 mm.

In the part number, UB is the rectangular ultrasonic series, 2000 the sensing range in millimetres, F42 the rectangular housing, U the 0 to 10 V analog output and V15 an M12 5-pin plug.

Seven Star LLC supplies this sensor in Oman and the GCC as an independent supplier in Muscat.

Technical specifications of the UB2000-F42-U-V15

Parameter Specification
Manufacturer / part number Pepperl+Fuchs UB2000-F42-U-V15
Sensing range / adjustment range 60 to 2000 mm / 90 to 2000 mm; dead band 0 to 60 mm
Standard target 100 mm x 100 mm plate
Transducer frequency / response approx. 175 kHz / approx. 150 ms
Operating voltage 17 to 30 V DC, ripple 10 % pp; no-load current ≤ 50 mA
Output 1 analog output 0 to 10 V, load > 1 kΩ
Resolution 0.7 mm
Accuracy Characteristic deviation ± 1 % of full scale; repeat accuracy ± 0.1 %
Temperature influence ± 1 % of full scale (temperature compensated)
Synchronization Bi-directional; common mode max. 30 Hz; multiplex 30/n Hz
Indicators Green power, yellow evaluation range, red fault LED
Approvals cULus Listed, Class 2 Power Source; EN IEC 60947-5-2
Ambient temperature -25 to 70 °C
Housing ABS, IP54, M12 x 1 5-pin plug, 140 g, 80 x 80 x 34 mm

Teach-in and sound cone adjustment on the UB2000-F42-U-V15

The analog characteristic is set by the evaluation limits A1 and A2. Hold the A1 key for more than two seconds, place the target at the desired near distance, and press briefly to store it; repeat with the A2 key for the far point. A yellow LED flashes quickly when the target is detected, and the red LED shows if it is not recognised. Alternatively, wire the teach input to -UB for A1 and +UB for A2.

The beam width can be chosen as wide or narrow. A narrow cone reduces false echoes from nearby walls or pipe flanges, while a wide cone is more tolerant for uneven surfaces. The default setting uses A1 at 90 mm, A2 at 2000 mm and a wide sound lobe.

System fit and related parts

The UB2000-F42-U-V15 fits tank level, stacker height, roll diameter and loop control where a 0 to 10 V signal is used. Siblings in the same housing include the UB2000-F42-I-V15 with current output and the UB2000-F42-E5-V15, E6, E7 with switching outputs. For short range in M30, see the UC500-30GM-IUR2-V15.

Selection and ordering checklist

  • Distance range and dead band: nearest target must be beyond 60 mm.
  • Target shape and surface, and wide or narrow sound cone needed.
  • 0 to 10 V versus 4 to 20 mA input on the controller.
  • Supply 17 to 30 V DC.
  • IP54 protection suits indoor or sheltered use only.
  • Synchronization if multiple sensors point at one area.

Installation, commissioning and maintenance of the UB2000-F42-U-V15

Mount with four screws through the housing corners, aim the transducer square to the target and keep the sound cone clear of brackets. After teaching A1 and A2, verify the 0 to 10 V output at both ends with a voltmeter. Dirt and condensation on the transducer cover will reduce the range, so clean it on schedule.

Because the housing is IP54 rather than a sealed M30 type, shield it from jets, heavy rain and direct sun.

Using the 0 to 10 V output of the UB2000-F42-U-V15

A 0 to 10 V signal is more sensitive to cable length and electrical noise than a current loop, so keep the cable of the UB2000-F42-U-V15 short, screened and away from motor and drive cables. The load must be above 1 kΩ, which most PLC analog inputs satisfy, and the common (-UB) of the sensor must share a reference with the controller to avoid offset errors.

The output follows a rising ramp, a falling ramp or a zero-line mode between A1 and A2. Choose the ramp that gives the controller the intuitive direction, for example higher voltage for a fuller tank. Leave a reserve at both ends of the range, because the dead band of 60 mm and the temperature drift of ± 1 % mean the extreme values are not perfectly stable.

Typical applications in Oman and the GCC

The UB2000-F42-U-V15 is used for tank and silo level, pallet and stack height, and web diameter measurement in water, cement, packaging and logistics operations in Oman. Temperature compensation helps in hot sheds, but avoid shimmering hot air plumes in the sound path.

Family comparison

Part Key difference
UB2000-F42-U-V15 (this part) 0 to 10 V analog, 60 to 2000 mm
UB2000-F42-I-V15 4 to 20 mA analog version
UB2000-F42-E5-V15 Switching output version
UC500-30GM-IUR2-V15 M30, 30 to 500 mm, current and voltage

Information to send with an RFQ

  • Part number UB2000-F42-U-V15 and quantity
  • Target description and distance
  • Required output
  • Supply voltage
  • Operating temperature and location
  • Delivery location

Documents and quotation

The manufacturer datasheet for UB2000-F42-U-V15 is attached on this page, so you can check wiring, approvals and dimensions before ordering. Send the exact part number, quantity and delivery location in Oman or the GCC and Seven Star LLC will reply with a quotation.

Seven Star LLC is an independent supplier in Muscat and is not the manufacturer; confirm availability, lead time and any project approval requirements in your RFQ.

Datasheets & Documents
  • PDF Datasheet Pepperl+Fuchs UB2000-F42-U-V15 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs UB2000-F42-U-V15 Ultrasonic Sensor

Answers from our engineering team on installation, compatibility and integration.

01What is the range of the UB2000-F42-U-V15?
Sensing range is 60 to 2000 mm with adjustment range 90 to 2000 mm and a dead band of 0 to 60 mm.
02What output signal is provided?
One analog 0 to 10 V output into loads above 1 kΩ, with 0.7 mm resolution.
03How is the sensor taught?
With the A1 and A2 membrane keys on the housing, or electrically through the teach input wired to -UB or +UB.
04Can the sound cone be changed?
Yes, the beam width is adjustable between wide and narrow to avoid interference close to the sensor.
05What protection and supply apply?
IP54 housing in ABS, operating voltage 17 to 30 V DC with up to 50 mA no-load current.