Brand: Phoenix Contact
Phoenix Contact CBM E4 24DC/0.5-10A NO-R Circuit Breaker
Description
CBM E4 24DC/0.5-10A NO-R: four-channel electronic circuit breaker for 24 V DC loads
The Phoenix Contact CBM E4 24DC/0.5-10A NO-R (order no. 2905743) is a four-channel electronic circuit breaker from the CBM range, built for 24 V DC control circuits that need finer current steps and more installation flexibility than the CBMC series. Each channel is adjustable to 0.5, 1, 2, 4, 6 or 10 A, which allows very light loads such as a single sensor to be protected close to their real current. The code reads CBM for the family, E4 for four electronic channels, 24DC for the voltage, 0.5-10A for the range, NO for the N/O signalling contact and R for the reset input. The housing is 41 mm wide and 130 mm high, larger than the CBMC modules, and it offers a wider ambient temperature range and marine-related data.
Seven Star LLC supplies it as an independent supplier in Muscat for projects in Oman and the GCC.
Technical specifications of the CBM E4 24DC/0.5-10A NO-R
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Phoenix Contact CBM E4 24DC/0.5-10A NO-R (order no. 2905743) |
| Product family | CBM, DIN-rail module, one piece, 4 channels |
| Operating voltage | 16.5 V DC … 30 V DC |
| Rated current per channel | 0.5 / 1 / 2 / 4 / 6 / 10 A DC (adjustable); pre-adjusted 0.5 A |
| Maximum total current | max. 40 A, available up to 70 °C |
| Active current limitation | typ. 2.0 x IN (0.5 to 1 A); typ. 1.5 x IN (2 to 10 A) |
| Short-circuit switching capacity | 300 A |
| Shutdown time | typ. 0.02 s above 1.3 x IN; typ. 30 s at 1.1 to 1.3 x IN |
| Waiting time after trip | 10 s |
| Maximum capacitive load | 75000 μF per channel at 24 V DC |
| Undervoltage / overvoltage switch-off | ≤ 15.8 V DC / ≥ 30.5 V DC |
| Reset input | 7 to 30 V DC, reset on falling edge, pulse ≥ 50 ms |
| Status output | 24 V DC, max. 20 mA, active when load exceeds 80 % on at least one channel |
| Remote indication contact | N/O, 0 to 30 V DC, 1 to 100 mA DC |
| Dimensions (W x H x D) | 41 x 130 x 121 mm including DIN rail |
| Ambient temperature, operation | -25 °C to 70 °C; start-up at -40 °C type tested; altitude up to 6000 m |
| Listings shown for this device | UL/C-UL Listed UL 508, UL Recognized UL 2367, Class I Div 2 Groups A-D (ISA 12.12.01), DNV GL, ISA S71.04 G3 |
How the CBM E4 24DC/0.5-10A NO-R protects each output channel
The CBM E4 uses a two-stage characteristic. Above about 1.3 times nominal current it trips quickly, typically in 20 ms, while currents of 1.1 to 1.3 times nominal are tolerated for about 30 seconds, which lets loads with start-up peaks run without nuisance trips. During an overload, the module limits the current actively to about twice nominal on the 0.5 and 1 A settings and about 1.5 times nominal on 2 to 10 A. After a trip, the channel waits 10 seconds. A nominal current assistant, indicated by yellow-green flashing, helps you find a suitable setting from the real load.
The DC OK LED reports supply status: green in the 16.5 to 30 V range, yellow for undervoltage below 15.8 V, red for overvoltage above 30.5 V. A reset input allows an external signal to re-enable tripped channels, and the status output can feed a PLC when any channel exceeds 80 % load.
Where the CBM E4 24DC/0.5-10A NO-R fits in a 24 V DC system
Typical use is behind a 24 V DC supply on a heavy-duty control panel, protecting PLC supply, I/O, sensors, actuators and communication gear individually. The reset input suits central panels where a controller or push-button must restore tripped branches, and the 70 °C rating and altitude data make it attractive for harsh conditions. If you need simpler wiring with no reset input, the CBMC E4 24DC/1-10A NO (2906032) is the smaller option; the CBMC E4 24DC/1-4A NO (2906031) covers lighter loads, and the IO-Link type 2910411 adds digital communication.
Selection and ordering checklist
- Confirm each branch current is covered by the discrete steps 0.5, 1, 2, 4, 6 or 10 A.
- Check that the supply stays above 16.5 V DC during normal operation.
- Decide whether a reset signal (7 to 30 V DC) and the status output will be wired.
- Check capacitive loads against the 75000 μF per channel limit.
- Confirm the requirement for DNV GL or hazardous-location (Class I Div 2) data as shown on the datasheet.
- Check the 41 mm width and 130 mm height against the available rail space.
Installation, commissioning and maintenance
Install on a 35 mm DIN rail, connect the supply to the push-in IN terminals and each load to an OUT terminal. Connect the optional reset and status wiring according to the terminal markings. Begin commissioning with the lowest setting and use the nominal current assistant on each channel, then lock settings. Observe the vibration data: the datasheet quotes 5 to 24.9 Hz with 1.6 mm amplitude and 24.9 to 150 Hz at 4 g, which suits equipment with moving machinery.
Maintenance is mostly visual: read the DC OK and channel LEDs, check the remote contact and verify the reset function during periodic tests. Keep a spare for critical panels because replacing the module is fast, but the setpoints must be re-entered.
Typical applications in Oman and the GCC
In Oman and the GCC, the 70 °C operating limit and G3 corrosive-gas listing make this module a candidate for compressor stations, offshore and coastal installations, desalination plants and power-generation auxiliaries. Where marine or offshore requirements apply, the datasheet lists DNV GL data for this device, but the project documents must still be checked against the exact class rules. The tolerance for short current peaks suits pumps, valves and contactor coils with inrush.
Comparison with sibling devices
| Device | Distinguishing data |
|---|---|
| CBM E4 24DC/0.5-10A NO-R (2905743) | 0.5-10 A steps, 40 A total, 70 °C, reset and status, DNV GL |
| CBMC E4 24DC/1-10A NO (2906032) | 1-10 A, 40 A input, 60 °C, N/O contact only |
| CBMC E4 24DC/1-4A NO (2906031) | 1-4 A, 16 A input |
| CBMC E4 24DC/1-10A IOL (2910411) | 1-10 A, IO-Link V1.1 |
Information to send with an RFQ
- Full part number and quantity.
- Branch currents and any inrush data.
- Supply unit and minimum voltage.
- Whether DNV GL or Class I Div 2 documentation is needed.
- Panel temperature and altitude.
- Delivery location and date.
Documents and quotation
Send us the part number CBM E4 24DC/0.5-10A NO-R and the quantity you need, and we will confirm which official documents are available for this device. Seven Star LLC is an independent supplier in Muscat and quotes for projects across Oman and the GCC; we do not act on behalf of the manufacturer.
Please also tell us the delivery location and required timeline so that availability can be checked before you commit to a project schedule.
Reviews (0)
How would you rate this product? Cancel reply
About brand
Phoenix Contact is a German, family-owned manufacturer of electrical connection technology and industrial automation, founded in 1923 in Essen by Hugo Knümann. It began as a sales company, and in 1928 Knümann developed the modular terminal block mounted on a rail, the product the company is still best known for. Phoenix Contact is headquartered in Blomberg, North Rhine-Westphalia.
Seven Star LLC lists Phoenix Contact surge protection, power supplies and safety relays, and sources these components by order number for panel builders and maintenance teams in Oman.
Phoenix Contact company profile
| Founded | 1923, Essen, Germany, by Hugo Knümann, as Phönix Elektro- und Industrie-Bedarfsgesellschaft |
|---|---|
| Headquarters | Blomberg, Germany |
| Ownership | Family-owned (Eisert and Stührenberg families) |
| Key invention | The modular terminal block on a DIN rail, 1928 |
| Product families | CLIPLINE terminal blocks, PCB terminals and connectors, QUINT and TRIO power supplies, relay modules, surge protection, signal conditioners, Ethernet switches and PLCnext controllers |
Milestones
- 1923: Hugo Knümann founds the company in Essen.
- 1928: The first modular terminal block is developed.
- Later: Headquarters move to Blomberg, Ostwestfalen-Lippe.
Phoenix Contact parts listed on this page
The TTC-6-2X1-24DC-UT (order number 2906799) is a surge protection device with screw connection for two 24 V DC signal wires that share a common reference potential. The QUINT-PS/1AC/24DC/10 is a single-phase DIN rail power supply delivering 24 V DC at 10 A. The PSR-SCP-24DC/ESP4/2X1/1X2 (order number 2981020) is a single-channel PSR safety relay for emergency stop and safety door monitoring, with two enabling current paths and plug-in screw terminals.
Phoenix Contact products we list
Ordering Phoenix Contact components: what we need
Phoenix Contact items are ordered by a seven-digit order number together with the type designation, both printed on the side of the module. Send both, plus the quantity. If the number is unreadable, send the type text and a photo. For power supplies, state input voltage, output current and whether the unit runs in parallel or with a redundancy module. For buyers in the GCC replacing an older unit, we check the manufacturer's documentation for the listed successor type.
Facts checked against Phoenix Contact's own company history (phoenixcontact.com), October 2026.
Browse Phoenix Contact products by category: Isolator & Barrier, Power Modules, Automation Accessories.
FAQ
Questions about the Phoenix Contact CBM E4 24DC/0.5-10A NO-R Circuit
Answers from our engineering team on installation, compatibility and integration.
01Which current steps are available on this breaker?
Each channel can be set to 0.5, 1, 2, 4, 6 or 10 A DC. The factory pre-adjusted value is 0.5 A.
02How does it treat small overloads?
Currents of 1.1 to 1.3 times nominal are tolerated for about 30 seconds, while currents above 1.3 times nominal trip typically in 20 ms.
03What does the reset input do?
It accepts 7 to 30 V DC and resets on a falling edge. The pulse should last at least 50 ms.
04What is the maximum operating temperature?
The ambient operating range is -25 to 70 degrees C, with start-up at -40 degrees C type tested.
05Which listings are shown on the datasheet?
UL/C-UL Listed UL 508, UL Recognized UL 2367, Class I Division 2 Groups A to D, DNV GL shipbuilding data and ISA S71.04 G3.