- Automation & ControlView all 1,652 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Isolator & Barrier
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Pepperl+Fuchs
Pepperl+Fuchs KFD2-USC-1.D Signal Converter with Trip Value
Description
KFD2-USC-1.D universal current and voltage signal converter with trip relay
The KFD2-USC-1.D is a configurable isolator for standard analog signals. It accepts a current, voltage or millivolt input from a field device, converts and scales it into a current or voltage output for the control system, and adds a relay contact that works as a trip value switch. A display and a front keypad let a technician set the ranges on site, with no configuration cable or PC needed.
Seven Star LLC supplies the KFD2-USC-1.D in Oman and the GCC as an independent supplier in Muscat. The sections below show where the converter belongs, what its measurement limits are and what to settle before ordering.
KFD2-USC-1.D designation and intended use
The KFD2-USC-1.D is a type designation of the Pepperl+Fuchs K-System, and the datasheet names it a signal converter with trip value, 1-channel, 24 V DC supply through the Power Rail. The display-and-keypad configuration is part of the feature list. The manufacturer states that the device provides isolation for non-intrinsically safe applications, which is an important limit: the module is for the safe area and does not replace an intrinsically safe barrier.
The input ranges named on the datasheet are 0 to 20 mA, 0 to 10 V and 0 to 60 mV, and any sub-range of these can be selected. Outputs are 0/4 to 20 mA, 0/2 to 10 V or 0/1 to 5 V.
Technical specifications of the KFD2-USC-1.D
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pepperl+Fuchs / KFD2-USC-1.D |
| Function | Signal converter with trip value, 1 channel, galvanic isolation, safe area |
| Input | Current 0 … 20 mA (terminals 2+, 3-); voltage 0 … 10 V or 0 … 60 mV (terminals 1+, 3-) |
| Input resistance | Voltage: 1 MΩ; current: max. 100 Ω |
| Input limit | 30 V |
| Resolution | 15 bit |
| Analog output | 0/4 … 20 mA (load max. 550 Ω) or 0/1 … 5 V, 0/2 … 10 V (load min. 1 kΩ) |
| Relay output | 250 V AC / 2 A / cos φ 0.7; 40 V DC / 2 A; mechanical life 2 x 107 cycles |
| Accuracy | Deviation 0.1 % of full scale |
| Temperature drift | 0.003 %/K (30 ppm) |
| Reaction time | ≥ 150 ms / ≤ 300 ms |
| Supply | 20 … 30 V DC, ≤ 80 mA, power consumption ≤ 1.6 W |
| Isolation | Input/output, input/supply, output/supply: reinforced insulation, 300 V rms (IEC/EN 61010-1) |
| Ambient temperature | -20 … 60 °C |
| Housing | Type B2, 20 x 119 x 115 mm, approx. 150 g, 35 mm DIN rail, IP20 |
How the KFD2-USC-1.D converts and monitors a signal
The input stage digitizes the field signal at 15 bit resolution and the converter rescales it to the output range chosen at the keypad. Because the output ranges and the input sub-ranges are independent, the same module can convert a 4-20 mA transmitter signal into 1-5 V for an old recorder, or turn a 0-10 V position feedback into a 4-20 mA value for a PLC card. A line fault detection function monitors the field wiring.
The relay works as a trip value contact. The user sets the switching threshold, and the display can show the process value in engineering units, which makes the module useful as a local indicator-and-alarm point as well as an isolator. The datasheet quotes a reaction time of not more than 300 ms, so the relay is suited to alarming, not to fast protection.
All three circuits, input, outputs and supply, are separated by reinforced insulation rated at 300 V rms, which protects the receiving system from common-mode voltages and ground loops between the plant and the control room.
Where the KFD2-USC-1.D fits
The module belongs to the display-and-keypad branch of the K-System, alongside the KFD2-GUT-1.D temperature converter, the KFD2-UFC-1.D frequency converter and the KFD2-CRG2-1.D transmitter supply. All of them share the same family of Power Rail, KFD2-EB2 power feed and K-DUCT wiring accessories.
Use the KFD2-USC-1.D when the field device is a non-Ex source that already has its own power: a drive output, a variable-speed signal, a mV shunt or an analog output from a package unit. When the field device needs loop power, the KFD2-CRG2-1.D or the STC5 transmitter supplies are the right choice.
Selection and ordering checklist for the KFD2-USC-1.D
- Define the input signal type and range: current, voltage or millivolt
- Define the required output signal and check the 550 Ω current or 1 kΩ voltage load limits
- Specify the trip value and the relay contact rating needed
- Confirm that the application is in the safe area, since the module is not for intrinsically safe circuits
- Confirm the 20 to 30 V DC supply and rail arrangement
- Confirm the cabinet ambient range against -20 to 60 °C
Setting up and maintaining the KFD2-USC-1.D
After mounting and wiring, set the input range, output range, scaling and trip point with the keypad. Check the line fault behaviour against the plant philosophy and verify the relay state during start-up and when power is lost. Record the settings on the loop sheet because a replacement module will need the same configuration.
For maintenance, use a calibrator at the input and verify the output and the relay threshold. With a deviation limit of 0.1 % of full scale, periodic verification only needs to be as frequent as the plant instrument policy requires.
Typical applications in Oman and the GCC
Typical places for a converter of this type include utilities and packaged equipment where drives, rectifiers or analyser panels deliver 0-10 V or 4-20 mA signals to a plant control system, and boiler and water treatment systems where a local alarm contact is needed at a measured value. In Gulf cabinets the 60 °C upper ambient limit of this module is lower than some other K-System modules, so confirm the actual cabinet temperature.
KFD2-USC-1.D and related display-type K-System modules
Based on the manufacturer datasheets.
| Part number | Input | Outputs | Width |
|---|---|---|---|
| KFD2-USC-1.D | mA, V or mV | Analog output and 1 relay | 20 mm |
| KFD2-GUT-1.D | RTD, thermocouple, potentiometer, voltage | Analog output and 2 relays | 40 mm |
| KFD2-UFC-1.D | Frequency 1 mHz … 10 kHz | Analog output, 2 relays, 1 transistor | 40 mm |
| KFD2-CRG2-1.D | Loop-powered 0/4 … 20 mA | Analog output and 2 relays | 40 mm |
Information to send with an RFQ for the KFD2-USC-1.D
Provide these details for a quick quotation.
- Input and output signal types and ranges
- Trip value and relay requirement
- Whether a display and keypad variant (.D) is required
- Quantity and delivery date
Documents and quotation
The manufacturer datasheet for the KFD2-USC-1.D is attached on this page, so the electrical data, terminal assignment and ambient limits quoted above can be checked against the original document before an order is placed.
Seven Star LLC supplies Pepperl+Fuchs products in Oman and the GCC as an independent supplier in Muscat. Send the quantity, the signal types and the project delivery date, and we will confirm availability and lead time in a written quotation.
Other Models in the Pf Kfd2 D Series Range
Seven Star LLC supplies models from the Pf Kfd2 D Series range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-USC-1.D Signal Converter with Trip Value | Isolator & Barrier | You are viewing this model |
| Pepperl+Fuchs KFD2-GUT-1.D Temperature Converter, 2 Relays | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-UFC-1.D Frequency Converter with Trip Values | Isolator & Barrier | View details |
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-USC-1.D Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-USC-1.D Signal Converter with
Answers from our engineering team on installation, compatibility and integration.
01What input signals does the KFD2-USC-1.D accept?
The datasheet lists 0 to 20 mA, 0 to 10 V and 0 to 60 mV, with selectable sub-ranges of these.
02Can it be used in intrinsically safe circuits?
No. The manufacturer describes it as providing isolation for non-intrinsically safe applications. For intrinsically safe loops an appropriate barrier is needed.
03What is the relay rating?
250 V AC / 2 A at cos phi 0.7 and 40 V DC / 2 A, with a mechanical life of 2 x 10 to the power 7 cycles.
04How is it configured?
By the keypad and display on the front of the unit, which also shows the measured value in selectable physical units.
05What accuracy is stated?
The datasheet gives a deviation of 0.1 % of full-scale value and a temperature influence of 0.003 %/K.


















Reviews