Brand: AMETEK
AMETEK Land CDB Non-Contact Boiler Gas Thermometer
Description
AMETEK Land CDB non-contact gas thermometer for boilers and incinerators
The AMETEK Land CDB is a fixed, non-contact infrared thermometer designed to measure the true temperature of the hot gas inside a boiler or incinerator, rather than the temperature of walls or deposits. It does this by “seeing” through the cooler ambient atmosphere to the main combustion product, hot carbon dioxide, and applying spectral filtering to the CO2 emission. The result is a gas temperature that is unaffected by other gases in the sight path.
The name is a model code from the AMETEK Land furnace gas temperature range. The thermometer was first designed for incineration of waste and biomass, but it also serves furnace exit gas temperature (FEGT) measurement in power generation and industrial boilers, as long as the path length through the hot gas is long enough. Seven Star LLC supplies the CDB in Oman and the GCC as an independent supplier in Muscat.
CDB technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | AMETEK Land (LAND Instruments International) / CDB |
| Measurement | True gas temperature via hot CO2 spectral filtering |
| Range | 400 to 1800 °C (752 to 3272 °F) |
| Field of view | Parallel beam, < 20 mm diameter to 900 mm (35 in) |
| Output | 4 to 20 mA linear, 2-wire loop connection |
| Power supply | 11 to 45 V DC |
| Response time | 1 to 10 seconds, adjustable |
| Emissivity adjustment | 0.1 to 1.09 in steps of 0.01 |
| Resolution | < 0.5 °C / 1 °F |
| Accuracy | 0.5 % of reading in K or 5 °C (9 °F), whichever is higher |
| Ambient temperature limits | 5 to 50 °C (41 to 122 °F) |
| Drift with ambient | < 2 degrees per 10 degrees of ambient change |
| Drift with time | < 1 °C (2 °F) per year |
| Sealing | To IP65 / NEMA 4X requirements |
| Vibration | 3 g, 10 to 300 Hz |
| CE compliance | EN 50-082-2 (immunity), EN 50-081-1 (emission), IEC 1010 (safety) |
How the CDB measures gas temperature
A normal pyrometer looks at a surface. A flame or hot gas is not a surface, so its emission is selective: hot CO2 radiates strongly in a narrow infrared band. The CDB is tuned to that band. Because the cold CO2 in the surrounding atmosphere absorbs less of that radiation than the hot gas emits, the instrument can view across the furnace and respond to the hot gas along its sight path.
It works without touching the process, around the clock, with its sight path extended above the furnace bed. Output is a standard 4–20 mA signal on a two-wire loop, so the same pair of wires carries power and signal, and the reading goes straight to a DCS or PLC analogue input.
Mounting the CDB and System 4 accessories
The CDB fits the AMETEK Land System 4 accessory range, including air- or water-cooled jackets and air-purged sighting tubes. In a furnace this matters: the sighting tube keeps the optics clear of ash and condensing deposits, and a cooled jacket allows installation in hot locations where the 5 to 50 °C ambient limit would otherwise be exceeded.
Because the instrument is fitted externally, there is no interaction with combustion and little to maintain. The parallel beam of under 20 mm diameter to 900 mm helps to keep the target defined and the measurement independent of distance.
Where the CDB fits in the boiler control system
Gas temperature in the furnace exit zone indicates how much heat has been absorbed by the radiant section. In an incinerator the same signal supports compliance with minimum combustion temperature, and in a boiler it supports FEGT-based performance and fouling checks. The signal is a standard loop signal, so it can be wired alongside thermocouple readings for comparison.
Other AMETEK Land thermometers in the range measure surfaces instead of gas; for a hazardous-area surface pyrometer, see the SPOT+ pyrometers and their EXSH1 housing. The CDB is for gas temperature only.
Selection and ordering checklist for the CDB
- Expected gas temperature: the range is 400 to 1800 °C.
- Path length: the hot gas path across the furnace must be long enough for a stable reading.
- Mounting position: above the bed in an incinerator, or at the furnace exit in a boiler.
- Accessories: air- or water-cooled jacket, or purged sighting tube, for the ambient and dust conditions.
- Power and signal: a 24 V DC loop supply within 11 to 45 V DC.
- Atmosphere: confirm whether the area is classified, since this brochure does not list hazardous-area certification for the CDB.
Installation, set-up and maintenance of the CDB
Align the instrument so the sight path crosses the hot gas without being blocked by a cold wall, and fit a purged sighting tube where the furnace gas carries ash. Set the response time between 1 and 10 seconds to suit the control loop: a short value follows rapid changes, while a longer value smooths a noisy signal. The emissivity setting is adjustable from 0.1 to 1.09, and the setting used at commissioning should be recorded with the loop sheet.
Maintenance is light. Inspect the window or sighting tube purge, keep the loop supply clean and compare the reading with a reference at planned shutdowns. The specified drift of less than 1 °C per year means recalibration intervals can be long.
Typical applications in Oman and the GCC
Typical sites are waste-to-energy and medical or industrial waste incinerators, biomass and utility boilers and fired heaters. In the Gulf, the high ambient temperature near boiler walls is an important design point, and cooled jackets help to keep the instrument inside its ambient limit.
Information to send with your CDB RFQ
- Type of furnace, boiler or incinerator and the fuel
- Expected gas temperature and the length of the hot gas path
- Ambient temperature at the mounting point and any dust or ash
- Accessories needed, such as jacket and sighting tube
- Receiving system and loop supply
- Quantity and delivery location
Documents and quotation
The AMETEK Land CDB brochure is attached on this page.
Send the CDB part number with your furnace data and we will confirm the configuration and quote. Seven Star LLC is an independent supplier in Muscat.
Datasheets & Documents
- Brochure AMETEK Land CDB Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK Land CDB Non-Contact Boiler Gas Thermometer
Answers from our engineering team on installation, compatibility and integration.
01What does the CDB thermometer measure?
It measures the true temperature of hot gas in boilers and incinerators using spectral filtering of hot carbon dioxide emission.
02What is the CDB temperature range and output?
The range is 400 to 1800 °C. The output is a linear 4–20 mA on a 2-wire loop powered from 11 to 45 V DC.
03What are the CDB ambient limits?
The specified ambient range is 5 to 50 °C. Cooled jackets and sighting tubes from the System 4 range help in hotter locations.
04What accuracy does the CDB have?
Accuracy is 0.5 % of reading in kelvin or 5 °C, whichever is higher, with resolution below 0.5 °C and drift below 1 °C per year.
05Can the CDB be used for furnace exit gas temperature?
Yes. The manufacturer states it can measure FEGT in power generation and industrial boilers, provided the path length through the gas is sufficient.